Sources of variability of gated myocardial perfusion SPECT quantitative parameters

被引:6
作者
DePuey, E. Gordon [1 ,2 ,3 ]
机构
[1] Mt Sinai St Lukes Hosp, New York, NY 10025 USA
[2] Mt Sinai Roosevelt Hosp, New York, NY 10025 USA
[3] Mt Sinai Icahn Sch Med, New York, NY USA
关键词
D O I
10.1007/s12350-015-0267-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the new solid-state dedicated cardiac cameras provide excellent spatial and energy resolution and allow for markedly reduced SPECT acquisition times and/or injected radiopharmaceutical activity, they have some distinct disadvantages compared to traditional sodium iodide SPECT cameras. They are expensive. Attenuation correction is not available. Cardio-focused collimation, advantageous to increase depth-dependent resolution and myocardial count density, accentuates diaphragmatic attenuation and scatter from subdiaphragmatic structures. Although supplemental prone imaging is therefore routinely advised, many patients cannot tolerate it. Moreover, very large patients cannot be accommodated in the solid-state camera gantries. Since data are acquired simultaneously with an arc of solid-state detectors around the chest, no temporally dependent "rotating" projection images are obtained. Therefore, patient motion can be neither detected nor corrected. In contrast, traditional sodium iodide SPECT cameras provide rotating projection images to allow technologists and physicians to detect and correct patient motion and to accurately detect the position of soft tissue attenuators and to anticipate associated artifacts. Very large patients are easily accommodated. Low-dose x-ray attenuation correction is widely available. Also, relatively inexpensive low-count density software is provided by many vendors, allowing shorter SPECT acquisition times and reduced injected activity approaching that achievable with solid-state cameras.
引用
收藏
页码:818 / 823
页数:6
相关论文
共 8 条
[1]   Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection [J].
DePuey, E. Gordon ;
Gadiraju, Ramesh ;
Clark, John ;
Thompson, Linda ;
Anstett, Frank ;
Shwartz, Shuli C. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (04) :547-563
[2]   Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum [J].
DePuey, E. Gordon ;
Bommireddipalli, Srinivas ;
Clark, John ;
Thompson, Linda ;
Srour, Yossi .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (05) :736-752
[3]   Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT [J].
DePuey, EG ;
Parmett, S ;
Ghesani, M ;
Rozanski, A ;
Nichols, K ;
Salensky, H .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (03) :278-285
[4]   Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods [J].
Faber, TL ;
Vansant, JP ;
Pettigrew, RI ;
Galt, JR ;
Blais, M ;
Chatzimavroudis, G ;
Cooke, CD ;
Folks, RD ;
Waldrop, SM ;
Gurtler-Krawczynska, E ;
Wittry, MD ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) :645-651
[5]   Adopting new gamma cameras and reconstruction algorithms: Do we need to re-establish normal reference values? [J].
Miao, Timothy L. ;
Kansal, Vinay ;
Wells, R. Glenn ;
Ali, Iftikhar ;
Ruddy, Terrence D. ;
Chow, Benjamin J. W. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (04) :807-817
[6]   Reliability of enhanced gated SPECT in assessing wall motion of severely hypoperfused myocardium: Echocardiographic validation [J].
Nichols, K ;
DePuey, EG ;
Krasnow, N ;
Lefkowitz, D ;
Rozanski, A .
JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (04) :387-394
[7]   Do patient data ever exceed the partial volume limit in gated SPECT studies? [J].
Nichols, K ;
DePuey, EG ;
Friedman, MI ;
Rozanski, A .
JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (05) :484-490
[8]  
Rozanski A, 2000, J NUCL MED, V41, P1445