Radiobiological characterization of the very high dose rate and dose per pulse electron beams produced by an IORT (intra operative radiation therapy) dedicated linac

被引:7
|
作者
Scampoli, Paola [1 ,2 ]
Carpentieri, Carmela [3 ]
Giannelli, Marco [4 ]
Magaddino, Vera [5 ,6 ]
Manti, Lorenzo [2 ]
Moriello, Carmen [2 ]
Piliero, Maria Antonietta [4 ]
Righi, Sergio [7 ]
Di Martino, Fabio [4 ]
机构
[1] Univ Bern, Albert Einstein Ctr Fundamental Phys, LHEP, Bern, Switzerland
[2] Univ Napoli Federico II, Dept Phys, Naples, Italy
[3] Natl Ctr Radiat Protect & Computat Phys, Rome, Italy
[4] Azienda Osped Univ Pisana, UO Fis Sanit, Pisa, Italy
[5] Inst Radiophys, Radiooncol Dept, Lausanne, Switzerland
[6] CHU Vaudois, Lausanne, Switzerland
[7] Osped Galliera, UO Fis Sanit, Genoa, Italy
关键词
IORT RBE; cellular radiobiology; clonogenic cell survival; radiotherapy; MAMMALIAN-CELLS; INTRAOPERATIVE RADIOTHERAPY; IONIZATION CHAMBERS; SURVIVAL; ACCELERATOR;
D O I
10.21037/tcr.2017.05.21
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Intra operative radiation therapy (IORT) is a cancer treatment modality combining surgery and radiation therapy that permits the delivery of a large single dose of radiation at the time of the tumour resection. During the last years, IORT has become a widespread technique in clinical routine. This was possible thanks to the recent development of small dedicated, and hence very flexible, electron accelerators suitable for a surgical operation environment. However, the electron beams produced by these dedicated linacs are different with respect to those produced by linacs used in conventional radiation therapy in terms of dose rate (dose delivered/time of irradiation), dose per pulse (dose delivered per emitted beam pulse) and energy spectrum. In particular the very high dose rate and dose per pulse (i.e., respectively about 20 and 100 times greater than those of conventional radiation therapy) pose some radiobiological questions that have not yet been fully investigated. The aim of this work was to evaluate the relative biological effectiveness (RBE) of the IORT beams through the experimental construction of dose-response curves for cell survival. Methods: Since breast cancer represents the elective malignancy for treatment by IORT, clonogenic survival was assayed in the MCF-7 cell line from breast tissue malignant adenocarcinoma as a function of dose for different dose rates (5, 25 and 75 Gy/min) and doses per pulse (4.2 and 7.4 cGy/pulse). Irradiations were performed at the IORT accelerator Novac7 (Hitesys SpA, Italy) delivering electrons at the nominal energy of 7 MeV. For comparison, irradiations were also carried out with a conventional radiotherapy accelerator (ClinacR DHX, Varian), providing a 6 MeV pulsed electron beam and 6 MV X-rays (dose rate and dose-per-pulse 2 Gy/min and 0.1 cGy/pulse respectively) as reference irradiations. Results: The IORT beam effectiveness was found almost the same with varying dose rate (5, 25 and 75 Gy/min) and dose per pulse (4.2 and 7.4 cGy/pulse). No significant difference was also found between IORT and conventional electron beams, while 6 MV X-rays (beam used in the conventional treatment of breast cancer) proved to be more effective. Conclusions: Data show that cell killing effectiveness of the electron beams from the IORT accelerator does not differ significantly from that of an electron beam used in conventional radiotherapy. This suggests that changes in the dose rate and dose per pulse, up to the values of 75 Gy/min and 7.4 cGy/pulse, do not affect the radiobiological characteristics of the beam. In the light of our results, new experimental data are needed to better compare the RBE of a IORT breast cancer treatment (5- 9 MeV electron beams, 21 Gy at the 90% isodose level in single fraction) and the RBE of a conventional breast cancer treatment (6 MV X- rays, 2 Gy per fraction, 30 fractions).
引用
收藏
页码:S761 / S768
页数:8
相关论文
共 50 条
  • [21] The radiobiological effect of intra-fraction dose-rate modulation in intensity modulated radiation therapy (IMRT)
    Bewes, J. M.
    Suchowerska, N.
    Jackson, M.
    Zhang, M.
    McKenzie, D. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13): : 3567 - 3578
  • [22] MONTE CARLO SIMULATION OF THE ELECTRON BEAMS PRODUCED BY A LINEAR ACCELERATOR FOR INTRA-OPERATIVE RADIATION THERAPY
    Mihailescu, D.
    Borcia, C.
    ROMANIAN REPORTS IN PHYSICS, 2014, 66 (01) : 61 - 74
  • [23] Fidelity of dose delivery at high dose rate of volumetric modulated arc therapy in a truebeam linac with flattening filter free beams
    Kalantzis, Georgios
    Qian, Jianguo
    Han, Bin
    Luxton, Gary
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (04) : 193 - 199
  • [24] Absorbed-dose-to-water measurement using alanine in ultra-high-pulse-dose-rate electron beams
    Bourgouin, Alexandra
    Hackel, Thomas
    Marinelli, Marco
    Kranzer, Rafael
    Schueller, Andreas
    Kapsch, Ralf-Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (20):
  • [25] Radiobiological influence of megavoltage electron pulses of ultra-high pulse dose rate on normal tissue cells
    Laschinsky, Lydia
    Karsch, Leonhard
    Lessmann, Elisabeth
    Oppelt, Melanie
    Pawelke, Joerg
    Richter, Christian
    Schuerer, Michael
    Beyreuther, Elke
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2016, 55 (03) : 381 - 391
  • [26] Radiobiological influence of megavoltage electron pulses of ultra-high pulse dose rate on normal tissue cells
    Lydia Laschinsky
    Leonhard Karsch
    Elisabeth Leßmann
    Melanie Oppelt
    Jörg Pawelke
    Christian Richter
    Michael Schürer
    Elke Beyreuther
    Radiation and Environmental Biophysics, 2016, 55 : 381 - 391
  • [27] Evaluating the performance characteristics of some ion chamber dosimeters in high dose per pulse intraoperative electron beam radiation therapy
    Baghani, Hamid Reza
    Robatjazi, Mostafa
    Mahdavi, Seied Rabi
    Aghdam, Seyed Rashid Hosseini
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 58 : 81 - 89
  • [28] The PTB water calorimeter for determining the absolute absorbed dose to water in ultra-high pulse dose rate electron beams
    Bourgouin, Alexandra
    Hackel, Thomas
    Kapsch, Ralf-Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [29] Ion collection efficiency of ionization chambers in ultra-high dose-per-pulse electron beams
    Kranzer, Rafael
    Poppinga, Daniela
    Weidner, Jan
    Schueller, Andreas
    Hackel, Thomas
    Looe, Hui Khee
    Poppe, Bjoern
    MEDICAL PHYSICS, 2021, 48 (02) : 819 - 830
  • [30] Characterization of the PTB ultra-high pulse dose rate reference electron beam
    Bourgouin, Alexandra
    Knyziak, Adrian
    Marinelli, Marco
    Kranzer, Rafael
    Schueller, Andreas
    Kapsch, Ralf-Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (08):