Radiobiological characterization of the very high dose rate and dose per pulse electron beams produced by an IORT (intra operative radiation therapy) dedicated linac

被引:7
|
作者
Scampoli, Paola [1 ,2 ]
Carpentieri, Carmela [3 ]
Giannelli, Marco [4 ]
Magaddino, Vera [5 ,6 ]
Manti, Lorenzo [2 ]
Moriello, Carmen [2 ]
Piliero, Maria Antonietta [4 ]
Righi, Sergio [7 ]
Di Martino, Fabio [4 ]
机构
[1] Univ Bern, Albert Einstein Ctr Fundamental Phys, LHEP, Bern, Switzerland
[2] Univ Napoli Federico II, Dept Phys, Naples, Italy
[3] Natl Ctr Radiat Protect & Computat Phys, Rome, Italy
[4] Azienda Osped Univ Pisana, UO Fis Sanit, Pisa, Italy
[5] Inst Radiophys, Radiooncol Dept, Lausanne, Switzerland
[6] CHU Vaudois, Lausanne, Switzerland
[7] Osped Galliera, UO Fis Sanit, Genoa, Italy
关键词
IORT RBE; cellular radiobiology; clonogenic cell survival; radiotherapy; MAMMALIAN-CELLS; INTRAOPERATIVE RADIOTHERAPY; IONIZATION CHAMBERS; SURVIVAL; ACCELERATOR;
D O I
10.21037/tcr.2017.05.21
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Intra operative radiation therapy (IORT) is a cancer treatment modality combining surgery and radiation therapy that permits the delivery of a large single dose of radiation at the time of the tumour resection. During the last years, IORT has become a widespread technique in clinical routine. This was possible thanks to the recent development of small dedicated, and hence very flexible, electron accelerators suitable for a surgical operation environment. However, the electron beams produced by these dedicated linacs are different with respect to those produced by linacs used in conventional radiation therapy in terms of dose rate (dose delivered/time of irradiation), dose per pulse (dose delivered per emitted beam pulse) and energy spectrum. In particular the very high dose rate and dose per pulse (i.e., respectively about 20 and 100 times greater than those of conventional radiation therapy) pose some radiobiological questions that have not yet been fully investigated. The aim of this work was to evaluate the relative biological effectiveness (RBE) of the IORT beams through the experimental construction of dose-response curves for cell survival. Methods: Since breast cancer represents the elective malignancy for treatment by IORT, clonogenic survival was assayed in the MCF-7 cell line from breast tissue malignant adenocarcinoma as a function of dose for different dose rates (5, 25 and 75 Gy/min) and doses per pulse (4.2 and 7.4 cGy/pulse). Irradiations were performed at the IORT accelerator Novac7 (Hitesys SpA, Italy) delivering electrons at the nominal energy of 7 MeV. For comparison, irradiations were also carried out with a conventional radiotherapy accelerator (ClinacR DHX, Varian), providing a 6 MeV pulsed electron beam and 6 MV X-rays (dose rate and dose-per-pulse 2 Gy/min and 0.1 cGy/pulse respectively) as reference irradiations. Results: The IORT beam effectiveness was found almost the same with varying dose rate (5, 25 and 75 Gy/min) and dose per pulse (4.2 and 7.4 cGy/pulse). No significant difference was also found between IORT and conventional electron beams, while 6 MV X-rays (beam used in the conventional treatment of breast cancer) proved to be more effective. Conclusions: Data show that cell killing effectiveness of the electron beams from the IORT accelerator does not differ significantly from that of an electron beam used in conventional radiotherapy. This suggests that changes in the dose rate and dose per pulse, up to the values of 75 Gy/min and 7.4 cGy/pulse, do not affect the radiobiological characteristics of the beam. In the light of our results, new experimental data are needed to better compare the RBE of a IORT breast cancer treatment (5- 9 MeV electron beams, 21 Gy at the 90% isodose level in single fraction) and the RBE of a conventional breast cancer treatment (6 MV X- rays, 2 Gy per fraction, 30 fractions).
引用
收藏
页码:S761 / S768
页数:8
相关论文
共 50 条
  • [1] Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy
    Di Venanzio, C.
    Marinelli, Marco
    Tonnetti, A.
    Verona-Rinati, G.
    Falco, M. D.
    Pimpinella, M.
    Ciccotelli, A.
    De Stefano, S.
    Felici, G.
    Marangoni, F.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 897 - 902
  • [2] Dosimetry of high intensity electron beams produced with dedicated accelerators in Intra-Operative Radiation Therapy (IORT)
    Lamanna, E.
    Fiorillo, A. S.
    Bruno, C.
    Santaniello, A.
    Siaka, Y. F. T.
    Berdondini, A.
    Bettuzzi, M.
    Brancaccio, R.
    Casali, F.
    Morigi, M. P.
    Barca, G.
    Castrovillari, F.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 732 - 738
  • [3] Dosimetry of High Intensity Electron Beams Produced by Dedicated Accelerators in Intra-Operative Radiation Therapy (IORT)
    Lamanna, Ernesto
    Fiorillo, Antonino Secondo
    Bruno, Carlo
    Santaniello, Anna
    Siaka, Yvette Flore Tchuente
    Berdondini, Andrea
    Bettuzzi, Matteo
    Brancaccio, Rosa
    Casali, Franco
    Morigi, Maria Pia
    Barca, Giuliana
    Castrovillari, Francesca
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 66 - 72
  • [4] Output factor measurement in high dose-per-pulse IORT electron beams
    Pimpinella, M.
    Andreoli, S.
    De Angelis, C.
    Della Monaca, S.
    D'Arienzo, M.
    Menegotti, L.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 94 - 102
  • [5] Characterization of Ultra-High-Dose Rate Electron Beams with ElectronFlash Linac
    Giuliano, Lucia
    Franciosini, Gaia
    Palumbo, Luigi
    Aggar, Lilia
    Dutreix, Marie
    Faillace, Luigi
    Favaudon, Vincent
    Felici, Giuseppe
    Galante, Federica
    Mostacci, Andrea
    Migliorati, Mauro
    Pacitti, Matteo
    Patriarca, Annalisa
    Heinrich, Sophie
    APPLIED SCIENCES-BASEL, 2023, 13 (01):
  • [6] BIORT: An experiment for the assessment of the biological effects of very high dose rate and dose per pulse electron irradiations
    Scampoli, P.
    Bisogni, M. G.
    Carpentieri, C.
    di Martino, F.
    Durante, M.
    Gialanella, G.
    Giannelli, M.
    Grossi, G.
    Magaddino, V.
    Manti, L.
    Moriello, C.
    Pugliese, M.
    Righi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2008, 31 (01): : 3 - 9
  • [7] BIORT: An experiment for the assessment of the biological effects of very high dose rate and dose per pulse electron irradiations
    Scampoli, P.
    Bisogni, M. G.
    Carpentieri, C.
    di Martino, F.
    Durante, M.
    Gialanella, G.
    Giannelli, M.
    Grossi, G.
    Magaddino, V.
    Manti, L.
    Moriello, C.
    Pugliese, M.
    Righi, S.
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-COLLOQUIA ON PHYSICS, 2008, 31 (01): : 3 - 9
  • [8] The Italian affair: The employment of parallel-plate ionization chambers for dose measurements in high dose-per-pulse IORT electron beams
    Cella, L.
    Liuzzi, R.
    Salvatore, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 2918 - 2924
  • [9] Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams
    Karaj, E.
    Righi, S.
    Di Martino, F.
    MEDICAL PHYSICS, 2007, 34 (03) : 952 - 958
  • [10] Dosimetry of Ultra-Short High Dose-Per-Pulse Very High Energy Electron Beams
    McManus, M.
    Romano, F.
    Lee, N.
    Wilfrid, F.
    Antonio, G.
    Royle, Gary
    Palmans, H.
    Subiel, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E372 - E372