Development of a PCR protocol for the detection of Escherichia coli O157:H7 and Salmonella spp. in surface water

被引:29
|
作者
Bonetta, Silvia [1 ]
Borelli, Elena [2 ]
Bonetta, Sara [1 ]
Conio, Osvaldo [2 ]
Palumbo, Franca [2 ]
Carraro, Elisabetta [1 ]
机构
[1] Univ Piemonte Orientale, Dipartimento Sci Ambiente & Vita, I-15121 Alessandria, Italy
[2] Lab Iride Acqua Gas Srl, I-16138 Genoa, Italy
关键词
Surface water; Salmonella; Escherichia coli O157:H7; PCR; REAL-TIME PCR; O157H7; O157-H7; GENE; HYBRIDIZATION; BACTERIOPHAGE; CULTIVATION; INDICATORS; ENRICHMENT; DRINKING;
D O I
10.1007/s10661-010-1650-x
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Escherichia coli O157:H7 and Salmonella are pathogenic microorganisms that can cause severe gastrointestinal illness in humans. These pathogens may be transmitted in a variety of ways, including food and water. The presence of Salmonella and E. coli O157:H7 in surface waters constitutes a potential threat to human health when used for either drinking or recreation. As with most waterborne pathogens, Salmonella and E. coli O157:H7 are difficult to detect and enumerate with accuracy in surface waters due to methodological limitations. The aim of this study was to develop a protocol for the detection of Salmonella spp., E. coli O157:H7 and E. coli virulence genes (stx (1), stx (2) and eae) in water using a single enrichment step and PCR. In spiked water samples, PCR results showed high sensitivity (< 3 CFU/L) for both microorganisms. The protocol developed in this study has been applied in different surface waters in association with microbiological and physical analysis. The frequency of PCR positive samples was 33% for Salmonella and 2% for E. coli O157:H7 producing intimin (eae) and Shiga-like toxin I (stx (1)). Moreover, the finding of amplicons corresponding to eae and stx (1) genes in the absence of E. coli O157:H7 suggested the possible presence of other pathogenic bacteria that carry these genes (e.g. EHEC, Shigella strains). The results obtained showed that the developed protocol could be applied as a routine analysis of surface water for the evaluation of microbiological risks.
引用
收藏
页码:493 / 503
页数:11
相关论文
共 50 条
  • [1] Development of a PCR protocol for the detection of Escherichia coli O157:H7 and Salmonella spp. in surface water
    Silvia Bonetta
    Elena Borelli
    Sara Bonetta
    Osvaldo Conio
    Franca Palumbo
    Elisabetta Carraro
    Environmental Monitoring and Assessment, 2011, 177 : 493 - 503
  • [2] Development of duplex PCR-ELISA for simultaneous detection of Salmonella spp. and Escherichia coli O157: H7 in food
    Hu, Jinqiang
    Huang, Runna
    Wang, Yi
    Wei, Xiangke
    Wang, Zhangcun
    Geng, Yao
    Jing, Jianzhou
    Gao, Hui
    Sun, Xincheng
    Dong, Caiwen
    Jiang, Chunpeng
    JOURNAL OF MICROBIOLOGICAL METHODS, 2018, 154 : 127 - 133
  • [3] Development of a triplex PCR assay for the specific detection of Campylobacter jejuni, Salmonella spp., and Escherichia coli O157:H7
    Gilbert, C
    Winters, D
    O'Leary, A
    Slavik, M
    MOLECULAR AND CELLULAR PROBES, 2003, 17 (04) : 135 - 138
  • [4] Multiplex DNA amplification to detect Escherichia coli O157:H7 and Salmonella spp. in bovine carcasses
    Garcia Lopez, E.
    Rubio Lozano, Ma. Salud
    Alonso Morales, R. A.
    Gayosso Vazquez, A.
    Miranda Castro, S. P.
    Nicoli Tolosa, M.
    Nunez Espinosa, J. F.
    CYTA-JOURNAL OF FOOD, 2009, 7 (01) : 31 - 36
  • [5] Multiplex PCR assay for the detection and quantification of Campylobacter spp., Escherichia coli O157:H7, and Salmonella serotypes in water samples
    Park, Si Hong
    Hanning, Irene
    Jarquin, Robin
    Moore, Philip
    Donoghue, Dan J.
    Donoghue, Ann M.
    Ricke, Steven C.
    FEMS MICROBIOLOGY LETTERS, 2011, 316 (01) : 7 - 15
  • [6] Detection of pathogenic Campylobacter, E-coli O157:H7 and Salmonella spp. in wastewater by PCR assay
    Bonetta, Si.
    Pignata, C.
    Lorenzi, E.
    De Ceglia, M.
    Meucci, L.
    Bonetta, Sa.
    Gilli, G.
    Carraro, E.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (15) : 15302 - 15309
  • [7] Direct PCR detection of Escherichia coli O157:H7
    Fode-Vaughan, KA
    Maki, JS
    Benson, JA
    Collins, MLP
    LETTERS IN APPLIED MICROBIOLOGY, 2003, 37 (03) : 239 - 243
  • [8] Detection of pathogenic Campylobacter, E. coli O157:H7 and Salmonella spp. in wastewater by PCR assay
    Si. Bonetta
    C. Pignata
    E. Lorenzi
    M. De Ceglia
    L. Meucci
    Sa. Bonetta
    G. Gilli
    E. Carraro
    Environmental Science and Pollution Research, 2016, 23 : 15302 - 15309
  • [9] Simultaneous detection of Escherichia coli O175:H7, Salmonella spp., and Listeria monocytogenes by multiplex PCR
    Germini, Andrea
    Masola, Annalisa
    Carnevali, Paola
    Marchelli, Rosangela
    FOOD CONTROL, 2009, 20 (08) : 733 - 738
  • [10] Development of PCR assays for detection of Escherichia coli O157:H7 in meat products
    Gordillo, Ruben
    Cordoba, Juan J.
    Andrade, Maria J.
    Isabel Luque, M.
    Rodriguez, Mar
    MEAT SCIENCE, 2011, 88 (04) : 767 - 773