Study of a new type slit injection pipe on pulse cleaning performance to the rectangular flat pleated filter

被引:12
作者
Hu, Shuda [1 ,2 ]
Li, Shihang [1 ,3 ]
Jin, Hao [1 ,2 ]
Xie, Biao [1 ,2 ]
Liu, Hao [1 ,2 ]
Tan, Xiaoyu [1 ,2 ]
Zhou, Fubao [1 ,2 ,4 ]
机构
[1] China Univ Min & Technol, Jiangsu Key Lab Fire Safety Urban Underground Spa, Xuzhou 221116, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Sch Safety Engn, Xuzhou 221116, Jiangsu, Peoples R China
[3] China Univ Min & Technol, State Key Lab Coal Resources & Mine Safety, Xuzhou 221116, Jiangsu, Peoples R China
[4] China Univ Min & Technol, Low Carbon Energy Inst, Jiangsu Key Lab Coal Based Greenhouse Gas Control, Xuzhou 221008, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
The rectangular flat pleated filter; Hole injection pipes; Slit injection pipes; Composite pressure; Pulse-jet uniformity; CARTRIDGE; DUST; FILTRATION; MEDIA; OPTIMIZATION; PARTICLES; OPERATION; PRESSURE; GEOMETRY; DESIGN;
D O I
10.1016/j.powtec.2021.08.074
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new slit injection pipe was designed to better clean the rectangular flat pleated filter using pulse cleaning technology. The pulse-jet performance of the slit injection pipe was compared with that of the hole injection pipe. The result showed that the pulse-jet intensity increased with the increase of tank pressure. The static pressure increased from the top to the bottom of the rectangular flat pleated filter during pulse-jet cleaning. The optimal jet distance decreased with the decrease of nozzle diameters of hole injection pipes. However, the optimal jet distance decreased as the slit nozzle width of silt injection pipes increased. Compared with the 7*D9 injection pipe, the peak positive pressures with a 120 mm jet distance at P3 and P6 increased by 441, 1339 Pa. The composite pressure and the pulse-jet uniformity increased by 744 Pa and 2.22 times, respectively. The slit injection pipe omega 1 has a higher pulse injection performance. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:459 / 467
页数:9
相关论文
共 34 条
[1]   Optimization of nozzle design for pulse cleaning of ceramic filter [J].
Chi Huachang ;
Yu Liang ;
Choi Joo-Hong ;
Ji Zhongli .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (02) :306-313
[2]   Experimental study on the nozzle effect of the pulse cleaning for the ceramic filter candle [J].
Choi, JH ;
Seo, YG ;
Chung, JW .
POWDER TECHNOLOGY, 2001, 114 (1-3) :129-135
[3]   Modeling instantaneous pressure drop of pleated thin filter media during dust loading [J].
Fotovati, S. ;
Hosseini, S. A. ;
Tafreshi, H. Vahedi ;
Pourdeyhimi, B. .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (18) :4036-4046
[4]   Filtration performance evaluation of depth filter media cartridges as function of layer structure and pleat count [J].
Hasolli, N. ;
Park, Y. O. ;
Rhee, Y. W. .
POWDER TECHNOLOGY, 2013, 237 :24-31
[5]  
[姬忠礼 Ji Zhongli], 2003, [化工学报, Journal of Chemical Industry and Engineering (China)], V54, P35
[6]   Influence of Humidity on Clogging of Flat and Pleated HEPA Filters [J].
Joubert, A. ;
Laborde, J. C. ;
Bouilloux, L. ;
Calle-Chazelet, S. ;
Thomas, D. .
AEROSOL SCIENCE AND TECHNOLOGY, 2010, 44 (12) :1065-1076
[7]  
[巨敏 Ju Min], 2013, [环境工程学报, Chinese Journal of Environmental Engineering], V7, P1091
[8]   A model analysis on the reasons for unstable operation of jet-pulsed filters [J].
Kavouras, A ;
Krammer, G .
POWDER TECHNOLOGY, 2005, 154 (01) :24-32
[9]   Effect of cone installation in a pleated filter cartridge during pulse-jet cleaning [J].
Li, Jianlong ;
Li, Shihang ;
Zhou, Fubao .
POWDER TECHNOLOGY, 2015, 284 :245-252
[10]  
Li Q, 2016, Study on Cleaning Performance of Flat Filter Cartridge during Pulse Cleaning