Study of poly(3,4-ethylendioxythiphene) as a coating for mitigation of biocorrosion of AISI 304 stainless steel in natural seawater

被引:22
|
作者
Aguirre, Javiera [4 ]
Daille, Leslie [3 ]
Fischer, Diego A. [1 ]
Galarce, Carlos [1 ]
Pizarro, Gonzalo [1 ,2 ]
Vargas, Ignacio [1 ,2 ]
Walczak, Magdalena [2 ,4 ]
de la Iglesia, Rodrigo [2 ,3 ]
Armijo, Francisco [2 ,5 ]
机构
[1] Pontificia Univ Catolica Chile, Escuela Ingn, Dept Ingn Hidraul & Ambiental, Vicuna Mackenna 4860, Santiago, Chile
[2] Marine Energy Res & Innovat Ctr, Avda Apoquindo 2827, Santiago, Chile
[3] Pontificia Univ Catolica Chile, Fac Ciencias Biol, Dept Genet Mol & Microbiol, Avda Libertador Bernardo OHiggins 340, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Escudo Ingn, Dept Ingn Mecan & Met, Vicuna Mackenna 4860, Santiago, Chile
[5] Pontificia Univ Catolica Chile, Fac Quim, Dept Quim Inorgan, Lab Bioelectroquim, Vicuna Mackenna 4860, Santiago, Chile
关键词
Poly(3,4-ethylenedioxythiophene); Antifouling; Coating; Marine corrosion; Stainless steel; Conducting polymer; MICROBIOLOGICALLY INFLUENCED CORROSION; SULFATE-REDUCING BACTERIA; STAINLESS-STEEL; MILD-STEEL; CONDUCTING POLYMERS; PROTECTION; POLYANILINE; POLYTHIOPHENE; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); ANTIBACTERIAL;
D O I
10.1016/j.porgcoat.2017.09.009
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In this work the poly(3,4-ethylenedioxythiophene) (PEDOT) was evaluated to mitigate biocorrosion of conventional stainless steel (SS), grade AISI 304, under exposure to natural seawater. PEDOT was obtained electrochemically onto the steel and coated coupons were immersed in flow-through exposure rig fed with fresh seawater. Corrosion performance of the coupons SS and SS/PEDOT was characterised using electrochemical analysis of open circuit potentials and polarization curves measured on samples retrieved after 7, 35 and 210 days of exposure. For the same retrieval times, the evolution of the biofilm was inspected by scanning electron microscopy (SEM), and microbiological analysis by denaturing gradient gel electrophoresis (DGGE) and fluorescence microscopy. Results indicate that PEDOT delays the growth of the biofilm on the modified steel surface by at least 35 days, producing a less variable bacterial community over time as compared to the uncoated steel surface. In addition, PEDOT retains electrochemical stability throughout the exposure, which is mainly attributed to the intrinsic properties of the conducting polymer.
引用
收藏
页码:175 / 184
页数:10
相关论文
共 6 条
  • [1] Investigation of the photocathodic protection of a transparent ZnO coating on an AISI type 304 stainless steel in a 3% NaCl solution
    Techapiesancharoenkij, Ratchatee
    Sripianem, Worapot
    Tongpul, Kamonchanok
    Peamjharean, Chanakorn
    Wichean, Thanate Na
    Meesak, Thanawat
    Eiamchai, Pitak
    SURFACE & COATINGS TECHNOLOGY, 2017, 320 : 97 - 102
  • [2] Frictional and wear behavior of Cr3C2-NiCr coating on AISI-304 stainless steel
    Mishra, Bir Bahadur
    Nautiyal, Hemant
    ADVANCES IN MATERIALS AND PROCESSING TECHNOLOGIES, 2022, 8 (04) : 4007 - 4017
  • [3] High temperature corrosion and wear behavior of HVOF-sprayed coating of It) Al2O3-NiAl on AISI 304 stainless steel
    Abu-warda, N.
    Lopez, A. J.
    Lopez, M. D.
    Utrilla, M. V.
    SURFACE & COATINGS TECHNOLOGY, 2019, 359 : 35 - 46
  • [4] Coating of AISI 304 stainless steel surface with addition of Cr3C2 to NiCrCo medium entropy alloy powder
    Imak, Anil
    MATERIALS TESTING, 2025,
  • [5] Effect of powder particle size on vibration damping behaviour of plasma sprayed alumina (Al2O3) coating on AISI 304 stainless steel substrate
    Sachidananda, K. B.
    Mahesha, K.
    Dey, Arjun
    CERAMICS INTERNATIONAL, 2018, 44 (01) : 158 - 163
  • [6] Development of strontium and magnesium substituted porous hydroxyapatite/poly(3,4-ethylenedioxythiophene) coating on surgical grade stainless steel and its bioactivity on osteoblast cells
    Gopi, D.
    Ramya, S.
    Rajeswari, D.
    Surendiran, M.
    Kavitha, L.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 114 : 234 - 240