Development of a Non-Invasive On-Chip Interconnect Health Sensing Method Based on Bit Error Rates

被引:1
作者
Shin, Insun [1 ]
Koo, Kyoungmin [1 ]
Kwon, Daeil [1 ]
机构
[1] Ulsan Natl Inst Sci & Technol, Sch Mech Aerosp & Nucl Engn, Ulsan 44919, South Korea
基金
新加坡国家研究基金会;
关键词
bit error rates; interconnect; prognostics; diagnosis; health management;
D O I
10.3390/s18103234
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electronic products and systems are widely used in industrial network systems, control devices, and data acquisition devices across many industry sectors. Failures of such electronic systems might lead to unexpected downtime, loss of productivity, additional work for repairs, and delay in product and service development. Thus, developing an appropriate sensing technique is necessary, because it is the first step in system fault diagnosis and prognosis. Many sensing techniques often require external and additional sensing devices, which might disturb system operation and consequently increase operating costs. In this study, we present an on-chip health sensing method for non-destructive and non-invasive interconnect degradation detection. Bit error rate (BER), which represents data integrity during digital signal transmission, was selected to sense interconnect health without connecting external sensing devices. To verify the health sensing performance, corrosion tests were conducted with in situ monitoring of the BER and direct current (DC) resistance. The eye size, extracted from the BER measurement, showed the highest separation between the intact and failed interconnect, as well as a gradual transition, compared with abrupt changes in the DC resistance, during interconnect degradation. These experimental results demonstrate the potential of the proposed sensing method for on-chip interconnect health monitoring applications without disturbing system operation.
引用
收藏
页数:13
相关论文
共 17 条
[1]  
[Anonymous], 2002, Standard IPC-9701
[2]   An Overview of Non-Destructive Testing Methods for Integrated Circuit Packaging Inspection [J].
Aryan, Pouria ;
Sampath, Santhakumar ;
Sohn, Hoon .
SENSORS, 2018, 18 (07)
[3]   Structural health monitoring of solder joints in QFN package [J].
Gershman, I. ;
Bernstein, J. B. .
MICROELECTRONICS RELIABILITY, 2012, 52 (12) :3011-3016
[4]   Discriminant Correlation Analysis: Real-Time Feature Level Fusion for Multimodal Biometric Recognition [J].
Haghighat, Mohammad ;
Abdel-Mottaleb, Mohamed ;
Alhalabi, Wadee .
IEEE TRANSACTIONS ON INFORMATION FORENSICS AND SECURITY, 2016, 11 (09) :1984-1996
[5]  
IPC and JEDEC, IPCJEDEC9702
[6]   In Situ Diagnostics and Prognostics of Wire Bonding Faults in IGBT Modules for Electric Vehicle Drives [J].
Ji, Bing ;
Pickert, Volker ;
Cao, Wenping ;
Zahawi, Bashar .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (12) :5568-5577
[7]   A digital technique for diagnosing interconnect degradation by using digital signal characteristics [J].
Lee, Jinwoo ;
Kwon, Daeil .
MICROELECTRONICS JOURNAL, 2017, 60 :87-93
[8]  
Li M.P., 2017, JITTER NOISE SIGNAL
[9]  
Okoro C, 2013, 2013 IEEE 63RD ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), P186, DOI 10.1109/ECTC.2013.6575570
[10]   Detecting Interconnect Damage in Shock Using Acoustic Emission Detection [J].
Ralph, W. Carter ;
Benedetto, Elizabeth Elias ;
Morscher, Gregory N. ;
Newman, Keith ;
Silk, Julie .