TERAHERTZ SUBWAVELENGTH STRUCTURES FOR SENSING AND NDE

被引:1
作者
Gopalsami, N. [1 ]
Heifetz, A. [1 ]
Chien, H. T. [1 ]
Raptis, A. C. [1 ]
机构
[1] Argonne Natl Lab, Nucl Engn Div, Lemont, IL 60439 USA
来源
REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 29A AND 29B | 2010年 / 1211卷
关键词
Terahertz; Surface Plasmons; FDTD; Spectroscopy and Imaging; Chemical Detection; Biological Detection; TRANSMISSION; SLIT;
D O I
10.1063/1.3362443
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The ability to control and concentrate electromagnetic (EM) energy in length scales much smaller than the excitation wavelength opens up new opportunities for sensing and NDE. Ordinarily EM wave transmission through such structures becomes infinitesimally small as the slit opening becomes much smaller than the wavelength; however, extraordinary transmission through these structures has been observed by researchers, which is believed to be due to surface plasmonic effect. We have investigated THz subwavelength slit structures for sensing and NDE. In a deep slit structure with subwavelength width, not only are the waves transmitted through, but also are found to be resonating because of the reflections caused by the impedance mismatch at the open ends. As a result, this structure can sense the dielectric properties of materials, which may be in gas, liquid, or solid forms, with high sensitivity and selectivity depending on the quality factor of the cavity resonance. Subwavelength aperture allows for near field imaging of materials with spatial resolution below the Abbe diffraction limit. To understand the electromagnetic (EM) wave propagation through subwavelength structures, we have performed a computational analysis of the EM fields with finite difference time domain (FDTD) technique. Simulated responses were compared with swept-frequency cw THz waves (230-300 GHz) in straight and stepped cavities with 50 pm slits on both ends and increased width in the middle. FDTD modeling of straight slits indicated Fabry-Perot (F-P) resonance peaks with low quality factor. We modified the slit to form a stepped cavity which increased the quality factor because of increased reflection coefficient at the slit ends. We fabricated straight and stepped cavities and tested with THz radiation in the 250-300 GHz range. The stepped cavity appears to have desirable features for sensing: good transmissivity, high-Q F-P resonance, compactness, and ruggedness.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 8 条
  • [1] Subwavelength slotted corrugated plate with enhanced quasioptical millimeter wave transmission
    Beruete, M
    Sorolla, M
    Campillo, I
    Dolado, JS
    [J]. IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2005, 15 (04) : 286 - 288
  • [2] Gopalsami N, 2009, AIP CONF PROC, V1096, P440
  • [3] Light in a subwavelength slit in a metal: Propagation and reflection
    Gordon, R
    [J]. PHYSICAL REVIEW B, 2006, 73 (15)
  • [4] Mimicking surface plasmons with structured surfaces
    Pendry, JB
    Martín-Moreno, L
    Garcia-Vidal, FJ
    [J]. SCIENCE, 2004, 305 (5685) : 847 - 848
  • [5] Terahertz field enhancement by a metallic nano slit operating beyond the skin-depth limit
    Seo, M. A.
    Park, H. R.
    Koo, S. M.
    Park, D. J.
    Kang, J. H.
    Suwal, O. K.
    Choi, S. S.
    Planken, P. C. M.
    Park, G. S.
    Park, N. K.
    Park, Q. H.
    Kim, D. S.
    [J]. NATURE PHOTONICS, 2009, 3 (03) : 152 - 156
  • [6] Finite conductance governs the resonance transmission of thin metal slits at microwave frequencies
    Suckling, JR
    Hibbins, AP
    Lockyear, MJ
    Preist, TW
    Sambles, JR
    Lawrence, CR
    [J]. PHYSICAL REVIEW LETTERS, 2004, 92 (14) : 147401 - 1
  • [7] Selective transmission through very deep zero-order metallic gratings at microwave frequencies
    Went, HE
    Hibbins, AP
    Sambles, JR
    Lawrence, CR
    Crick, AP
    [J]. APPLIED PHYSICS LETTERS, 2000, 77 (18) : 2789 - 2791
  • [8] Determination of microwave permittivities using a metallic slit
    Yang, FZ
    Sambles, JR
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (23) : 3049 - 3051