Measurement of the modulation transfer function of digital X-ray detectors with an opaque edge-test device

被引:26
作者
Illers, H
Buhr, E
Günther-Kohfahl, S
Neitzel, U
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[2] Philips Med Syst, D-22335 Hamburg, Germany
关键词
D O I
10.1093/rpd/nch506
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A variant of the edge method for the determination of the pre-sampled modulation transfer function (MTF) of digital X-ray imaging devices has been developed and accepted as the standard method in the novel DQE measurement standard IEC 62220-1. An opaque tungsten edge-test device accomplishes the ideal step-like profile of the incident X rays, The edge spread function is measured over a large region across the edge transition that enables, an accurate MTF measurement including the 'low-frequency drop'. The method has been applied to different state-of-the-art X-ray imaging detectors, a computed radiography, a CsI-based indirect and an Se-based direct flat-panel detector. The MTF measurement results will be presented. In contrast to the opaque edge device, the commonly used semi-transparent edge-test devices produce scatter radiation that deteriorates the incident X-ray profile, which leads to a systematic overestimation of the MTF.
引用
收藏
页码:214 / 219
页数:6
相关论文
共 11 条
[1]   Simple method for modulation transfer function determination of digital imaging detectors from edge images [J].
Buhr, E ;
Günther-Kohfahl, S ;
Neitzel, U .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :877-884
[2]   Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image [J].
Buhr, E ;
Günther-Kohfahl, S ;
Neitzel, U .
MEDICAL PHYSICS, 2003, 30 (09) :2323-2331
[3]   Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications [J].
Granfors, PR ;
Aufrichtig, R .
MEDICAL PHYSICS, 2000, 27 (06) :1324-1331
[4]   Evaluation of an algorithm for the assessment of the MTF using an edge method [J].
Greer, PB ;
van Doorn, T .
MEDICAL PHYSICS, 2000, 27 (09) :2048-2059
[5]  
ILLERS H, 2004, P SOC PHOTO-OPT INS, P177
[6]  
*INT EL COMM, 1994, MED DIAGN XRAY EQ RA
[7]  
*INT EL COMM, 2003, MED EL EQ CHAR DIG X
[8]   Image quality in two phosphor-based flat panel digital radiographic detectors [J].
Samei, E .
MEDICAL PHYSICS, 2003, 30 (07) :1747-1757
[9]   An experimental comparison of detector performance for direct and indirect digital radiography systems [J].
Samei, E ;
Flynn, MJ .
MEDICAL PHYSICS, 2003, 30 (04) :608-622
[10]   A method for measuring the presampled MTF of digital radiographic systems using an edge test device [J].
Samei, E ;
Flynn, MJ ;
Reimann, DA .
MEDICAL PHYSICS, 1998, 25 (01) :102-113