Accuracy of Blood Glucose Meters for Self-Monitoring Affects Glucose Control and Hypoglycemia Rate in Children and Adolescents with Type 1 Diabetes

被引:17
|
作者
Boettcher, Claudia [1 ]
Dost, Axel [2 ]
Wudy, Stefan A. [1 ]
Flechtner-Mors, Marion [3 ]
Borkenstein, Martin [4 ]
Schiel, Ralf [5 ]
Weitzel, Dieter [6 ]
Bechtold-Dalla Pozza, Susanne [7 ]
Wolf, Johannes [8 ]
Holl, Reinhard W. [3 ]
机构
[1] Univ Giessen, Div Paediat Endocrinol & Diabetol, Ctr Child & Adolescent Med, D-35392 Giessen, Germany
[2] Univ Hosp Jena, Dept Paediat, Jena, Germany
[3] Univ Ulm, Inst Epidemiol & Med Biometry, D-89069 Ulm, Germany
[4] Med Univ Graz, Dept Paediat, Graz, Austria
[5] MEDIGREIF Inselklin Heringsdorf, Dept Diabet & Metab Dis, Ostseebad Heringsdorf, Germany
[6] Childrens & Adolescents Outpatient Ctr, German Clin Diagnost, Wiesbaden, Germany
[7] Univ Munich, Paediat Endocrinol & Diabetol, Munich, Germany
[8] St Vincent Childrens Hosp, Paderborn, Germany
关键词
COGNITIVE FUNCTION; GLYCEMIC CONTROL; SYSTEMS; INSULIN; COMPLICATIONS; MULTICENTER; IMPACT;
D O I
10.1089/dia.2014.0262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/Hypothesis: This study investigated the accuracy of blood glucose meters for self-monitoring and its influence on glycated hemoglobin (HbA(1c)) levels and the frequency of hypoglycemic coma. Materials and Methods: Self-measured and simultaneously obtained laboratory blood glucose values from 9,163 patients with type 1 diabetes <18 years of age in the German/Austrian Diabetes Prospective Documentation Initiative registry were analyzed by investigating their compliance with the International Organization for Standardization (ISO) criteria (versions 2003 and 2013) and by error grid analyses. Regression models elucidated effects on glucose control and hypoglycemia rates. Results: Depending on the respective subgroup (defined by sex, age, duration of diabetes, mode of insulin therapy), 78.7-94.7% of the self-monitoring of blood glucose (SMBG) values met the old and 79.7-88.6% met the new ISO criteria. In Clarke and Parkes error grid analyses, the percentages of SMBG values in Zone A ranged between 92.8% and 94.6% (Clarke) and between 92.2% and 95.0% (Parkes). The patient group with SMBG devices measuring "far too low" (compared with the laboratory-obtained glucose levels) presented with a higher HbA(1c) level than those measuring "far too high," "too high," "identical/almost identical," or "too low" (based on quintiles of deviation). Performing "far too high" was associated with the highest rate of hypoglycemic coma in comparison with the other deviation quintiles. Conclusions: This study showed that current SMBG devices fulfilled neither the previous nor the new ISO criteria. Large deviations of the SMBG values from the "true" glucose levels resulted in higher HbA(1c) levels and markedly increased rates of hypoglycemic events.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [31] Self-monitoring of blood glucose
    不详
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2012, 66 : 2 - 93
  • [32] The Impact of Self Blood Glucose Monitoring and Insulin Regimen on Glycemic Control among Children and Adolescents with Type 1 Diabetes Mellitus
    Al-Agha, Abdulmoein E.
    Samargandy, Shireen A.
    Ahmed, Ihab Abd Elhameed
    El Derwi, Douaa Ahmed
    JOURNAL OF DIABETES & METABOLISM, 2015, 6 (06)
  • [33] Self-Monitoring of Blood Glucose in Patients with Type 2 Diabetes Not Using Insulin
    Cordts, Scott
    AMERICAN FAMILY PHYSICIAN, 2012, 85 (09) : 866 - 867
  • [34] Long-Term Cost-Effectiveness of Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose in Adults With Type 1 Diabetes in Iran
    Molaee, Mohsen Choband
    Naseri, Zahra Gharib
    Karami, Masoud Ali
    VALUE IN HEALTH REGIONAL ISSUES, 2024, 43
  • [35] Frequency of Self-Monitoring of Blood Glucose during the School Day Is Associated with the Optimal Glycemic Control among Korean Adolescents with Type 1 Diabetes
    Joo, Eun Young
    Lee, Ji-Eun
    Kang, Hee Sook
    Park, Shin Goo
    Hong, Yong Hee
    Shin, Young-Lim
    Sohn, Min
    DIABETES & METABOLISM JOURNAL, 2018, 42 (06) : 480 - 487
  • [36] Accuracy of Self-Monitored Blood Glucose in Type 2 Diabetes
    Kazlauskaite, Rasa
    Soni, Sonia
    Evans, Arthur T.
    Graham, Kelly
    Fisher, Betty
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (06) : 385 - 392
  • [38] Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose to Assess Glycemia in Gestational Diabetes
    Zaharieva, Dessi P.
    Teng, Jessie H.
    Ong, May Lea
    Lee, Melissa H.
    Paldus, Barbora
    Jackson, Linda
    Houlihan, Christine
    Shub, Alexis
    Tipnis, Sheetal
    Cohen, Ohad
    O'Neal, David N.
    Krishnamurthy, Balasubramanian
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (11) : 822 - 827
  • [39] The Effect of Blood Glucose Self-Monitoring Among Inmates With Diabetes
    Buskey, Robin N. Hunter
    Mathieson, Kathleen
    Leafman, Joan S.
    Feinglos, Mark N.
    JOURNAL OF CORRECTIONAL HEALTH CARE, 2015, 21 (04) : 343 - 354
  • [40] Hypoglycemia in children and adolescents with type 1 diabetes
    Ziegler, R.
    Kiess, W.