Accuracy of Blood Glucose Meters for Self-Monitoring Affects Glucose Control and Hypoglycemia Rate in Children and Adolescents with Type 1 Diabetes

被引:17
|
作者
Boettcher, Claudia [1 ]
Dost, Axel [2 ]
Wudy, Stefan A. [1 ]
Flechtner-Mors, Marion [3 ]
Borkenstein, Martin [4 ]
Schiel, Ralf [5 ]
Weitzel, Dieter [6 ]
Bechtold-Dalla Pozza, Susanne [7 ]
Wolf, Johannes [8 ]
Holl, Reinhard W. [3 ]
机构
[1] Univ Giessen, Div Paediat Endocrinol & Diabetol, Ctr Child & Adolescent Med, D-35392 Giessen, Germany
[2] Univ Hosp Jena, Dept Paediat, Jena, Germany
[3] Univ Ulm, Inst Epidemiol & Med Biometry, D-89069 Ulm, Germany
[4] Med Univ Graz, Dept Paediat, Graz, Austria
[5] MEDIGREIF Inselklin Heringsdorf, Dept Diabet & Metab Dis, Ostseebad Heringsdorf, Germany
[6] Childrens & Adolescents Outpatient Ctr, German Clin Diagnost, Wiesbaden, Germany
[7] Univ Munich, Paediat Endocrinol & Diabetol, Munich, Germany
[8] St Vincent Childrens Hosp, Paderborn, Germany
关键词
COGNITIVE FUNCTION; GLYCEMIC CONTROL; SYSTEMS; INSULIN; COMPLICATIONS; MULTICENTER; IMPACT;
D O I
10.1089/dia.2014.0262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/Hypothesis: This study investigated the accuracy of blood glucose meters for self-monitoring and its influence on glycated hemoglobin (HbA(1c)) levels and the frequency of hypoglycemic coma. Materials and Methods: Self-measured and simultaneously obtained laboratory blood glucose values from 9,163 patients with type 1 diabetes <18 years of age in the German/Austrian Diabetes Prospective Documentation Initiative registry were analyzed by investigating their compliance with the International Organization for Standardization (ISO) criteria (versions 2003 and 2013) and by error grid analyses. Regression models elucidated effects on glucose control and hypoglycemia rates. Results: Depending on the respective subgroup (defined by sex, age, duration of diabetes, mode of insulin therapy), 78.7-94.7% of the self-monitoring of blood glucose (SMBG) values met the old and 79.7-88.6% met the new ISO criteria. In Clarke and Parkes error grid analyses, the percentages of SMBG values in Zone A ranged between 92.8% and 94.6% (Clarke) and between 92.2% and 95.0% (Parkes). The patient group with SMBG devices measuring "far too low" (compared with the laboratory-obtained glucose levels) presented with a higher HbA(1c) level than those measuring "far too high," "too high," "identical/almost identical," or "too low" (based on quintiles of deviation). Performing "far too high" was associated with the highest rate of hypoglycemic coma in comparison with the other deviation quintiles. Conclusions: This study showed that current SMBG devices fulfilled neither the previous nor the new ISO criteria. Large deviations of the SMBG values from the "true" glucose levels resulted in higher HbA(1c) levels and markedly increased rates of hypoglycemic events.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [21] Blood glucose self-monitoring in type 2 diabetes: a randomised controlled trial
    Farmer, A. J.
    Wade, A. N.
    French, D. P.
    Simon, J.
    Yudkin, P.
    Gray, A.
    Craven, A.
    Goyder, L.
    Holman, R. R.
    Mant, D.
    Kinmonthl, A-L
    Neil, H. A. W.
    HEALTH TECHNOLOGY ASSESSMENT, 2009, 13 (15) : 1 - +
  • [22] Self-monitoring of blood glucose experiences of adults with type 2 diabetes
    Dlugasch, Lucie B.
    Ugarriza, Doris N.
    JOURNAL OF THE AMERICAN ASSOCIATION OF NURSE PRACTITIONERS, 2014, 26 (06) : 323 - 329
  • [23] Frequent Self-Monitoring Blood Glucose Correlated to Better Medication Adherence and Glycemic Control in Children with Type 1 Diabetes Mellitus
    Rochmah, Nur
    Soetjipto, Soetjipto
    Faizi, Muhammad
    Hisbiyah, Yuni
    Perwitasari, Rayi Kurnia
    Fedora, Katherine
    Rosyidah, Laili Nur
    Endarko, Endarko
    Kuswanto, Djoko
    Rini, Eka Agustia
    DIABETES METABOLIC SYNDROME AND OBESITY, 2024, 17 : 2203 - 2209
  • [24] Overview on self-monitoring of blood glucose
    Montagnana, Martina
    Caputo, Marco
    Giavarina, Davide
    Lippi, Giuseppe
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 7 - 13
  • [25] Comparable efficacy of self-monitoring of quantitative urine glucose with self-monitoring of blood glucose on glycaemic control in non-insulin-treated type 2 diabetes
    Lu, J.
    Bu, R. F.
    Sun, Z. L.
    Lu, Q. S.
    Jin, H.
    Wang, Y.
    Wang, S. H.
    Li, L.
    Xie, Z. L.
    Yang, B. Q.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 93 (02) : 179 - 186
  • [26] Cost-effectiveness of Continuous Glucose Monitoring for Adults With Type 1 Diabetes Compared With Self-Monitoring of Blood Glucose: The DIAMOND Randomized Trial
    Wan, Wen
    Skandari, M. Reza
    Minc, Alexa
    Nathan, Aviva G.
    Winn, Aaron
    Zarei, Parmida
    O'Grady, Michael
    Huang, Elbert S.
    DIABETES CARE, 2018, 41 (06) : 1227 - 1234
  • [27] Comparison of Different Models of Structured Self-Monitoring of Blood Glucose in Type 2 Diabetes
    Li, Ching-Lu
    Wu, Yueh-Chu
    Kornelius, Edy
    Chen, Yu-Ju
    Lin, Yu-Tze
    Hsiao, Huei-Wen
    Peng, Chiung-Huei
    Yang, Yi-Sun
    Huang, Chien-Ning
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (03) : 171 - 177
  • [28] Consensus Statement on Self-Monitoring of Blood Glucose in Diabetes
    Schnell, O.
    Alawi, H.
    Battelino, T.
    Ceriello, A.
    Diem, P.
    Felton, A.
    Grzeszczak, W.
    Harno, K.
    Kempler, P.
    Satman, I.
    Verges, B.
    DIABETES STOFFWECHSEL UND HERZ, 2009, 18 (04): : 285 - 289
  • [29] Self-Monitoring of Blood Glucose
    Garg, Satish K.
    Hirsch, Irl B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : S4 - S12
  • [30] Self-monitoring of blood glucose
    Garg, S.
    Hirsch, I. B.
    Bode, B. W.
    Battelino, T.
    Pickup, J.
    Dassau, E.
    Atlas, E.
    Phillip, M.
    Danne, T.
    Bolinder, J.
    Heinemann, L.
    Kaufman, N.
    Hod, M.
    Jovanovic, L.
    Spector, D.
    Shikora, S.
    Skyler, J. S.
    Zisser, H.
    Riddell, M. C.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2010, 64 : 1 - 69