Development of an agglutination-enhancement immunoturbidimetric tacrolimus assay with improved sensitivity

被引:2
|
作者
Wu, Fengbo [1 ]
Wang, Zhuo [2 ]
Dong, Jiafei [4 ]
Wang, Xuebin [2 ,3 ]
Wang, Lishui [4 ]
Liu, Binhu [1 ]
Cao, Guangyuan [1 ]
Wang, Zhaorui [5 ]
Cai, Min [6 ]
机构
[1] Shanghai Genext Med Technol Co Ltd, Shanghai 200433, Peoples R China
[2] Naval Med Univ, Shanghai Changhai Hosp, Dept Pharm, Shanghai 200433, Peoples R China
[3] Fudan Univ, Sch Pharm, Dept Microbiol & Biochem Pharm, Shanghai 201203, Peoples R China
[4] Shandong Univ, Dept Clin Lab, Qilu Hosp, Jinan 250012, Shandong, Peoples R China
[5] Peoples Hosp Zhengzhou, Dept Organ Transplantat, Zhengzhou 450000, Henan, Peoples R China
[6] PLA Joint Logist Support Force, Dept Lab & Transfus Med, Hosp 988, Zhengzhou 450000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Agglutination-enhancement; Immunoturbidimetric assay; Tacrolimus; Improved sensitivity; Therapeutic drug monitoring; IMMUNOASSAY;
D O I
10.1016/j.jpba.2021.114290
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate quantification of low level of blood drugs by Latex enhanced immunoturbidimetric assay (LEITA) remains a challenge due to its inherent limited sensitivity. To deal with this problem, we designed a new agglutination-enhancement strategy, and applied it for development of a highly sensitive and accurate tacrolimus LEITA. By this principle, a very small amount of biotin labeled anti-tacrolimus monoclonal antibodies (BLATMA) can arise agglutination strong enough for accurate reading of the increased absorbance since the BLATMA bears multiple biotin molecules, and the agglutination mediated by BLATMA can be inhibited by a similarly small amount of tacrolimus when the drug binds to BLATMA, giving rise to an improved sensitivity. The limit of detection (LOD) and functional sensitivity obtained by the proposed tacrolimus LEITA was 0.22 ng/mL and 0.59 ng/mL, respectively, 8-20 times more sensitive than the conventional drug-latex or antibody-latex based direct inhibition LEITA formats. Good precision was observed in the whole range of clinically significant tacrolimus concentration. The reliability of the tacrolimus LEITA was demonstrated by its strong correlation with both liquid chromatography-tandem mass spectrometry (LC-MS/MS) (R-2 = 0.977, slope = 0.998) and the ABBOTT tacrolimus chemiluminescent magnetic immunoassay (CMIA) (R-2 = 0.982, slope = 1.01) in the analysis of 119 clinical samples. It's concluded that the agglutination-enhancement strategy can be applied to construct highly sensitive LEITA for accurate tacrolimus analysis; owing to the improved sensitivity, this technique can be expected not only to improve the reliability of LEITA for low-level drug monitoring, but also to broaden the scope of analytes detectable by LEITA. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] USE OF LIPOSOMES AS AGGLUTINATION-ENHANCEMENT AGENTS IN DIAGNOSTIC-TESTS
    MARTIN, FJ
    KUNG, VT
    METHODS IN ENZYMOLOGY, 1987, 149 : 200 - 213
  • [2] Improved immunoturbidimetric assay for cystatin C
    Lewis, AV
    James, TJ
    McGuire, JBJ
    Taylor, RP
    ANNALS OF CLINICAL BIOCHEMISTRY, 2001, 38 : 111 - 114
  • [3] Improved assay characteristics of an immunoturbidimetric assay for cystatin C
    Gorst, J
    ANNALS OF CLINICAL BIOCHEMISTRY, 2001, 38 : 153 - 153
  • [4] Correction to 'Improved immunoturbidimetric assay for cystatin C'
    McGuire, JBJ
    James, TJ
    Taylor, RP
    ANNALS OF CLINICAL BIOCHEMISTRY, 2001, 38 : 572 - 573
  • [5] Development of an automated immunoturbidimetric ferritin assay
    Borque, L
    Rus, A
    Bellod, L
    Seco, ML
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1999, 37 (09) : 899 - 905
  • [6] Development of a new prealbumin automated immunoturbidimetric assay for serum and plasma.
    Shiojiri, M
    Adachi, H
    Hanada, T
    Kobatake, S
    Matsuura, S
    Mallory, T
    CLINICAL CHEMISTRY, 2004, 50 (06) : A64 - A64
  • [7] Development of a slide agglutination assay for detection of blastomycosis
    Hatch, Wayne O.
    Scalarone, Gene M.
    MICROBIOLOGY AND IMMUNOLOGY, 2013, 57 (11) : 756 - 761
  • [8] Clinical evaluation of an improved sensitivity Tacrolimus (FK506) assay by microparticle enzyme immunoassay.
    Cannon, RD
    Wong, SHY
    Hariharan, S
    Adams, MB
    Johnson, CP
    Roza, AM
    Pearson, ML
    Werner, CL
    CLINICAL CHEMISTRY, 1997, 43 : 496 - 496
  • [9] Development of latex immunoturbidimetric assay (LIA) for soluble transferrin receptor.
    Tanaka, S
    Hamano, A
    Umeda, M
    Naka, Y
    CLINICAL CHEMISTRY, 1999, 45 (06) : A58 - A58
  • [10] Development of latex agglutination assay for soluble fibrin (SF).
    Ueno, Y
    Tanaka, S
    Hamano, A
    Shibata, H
    CLINICAL CHEMISTRY, 1998, 44 : A52 - A52