Optimized hip-knee-ankle exoskeleton assistance at a range of walking speeds

被引:19
作者
Bryan, Gwendolyn M. [1 ]
Franks, Patrick W. [1 ]
Song, Seungmoon [1 ]
Voloshina, Alexandra S. [2 ]
Reyes, Ricardo [1 ]
O'Donovan, Meghan P. [3 ]
Gregorczyk, Karen N. [3 ]
Collins, Steven H. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Univ Calif Irvine, Mech & Aerosp Engn, Irvine, CA USA
[3] US Army, Natick Soldier Res Dev & Engn Ctr, Natick, MA 01760 USA
基金
美国国家卫生研究院;
关键词
Exoskeleton; Augmentation; Walking speed; Human-in-the-loop optimization; METABOLIC-RATE; LOCOMOTION; POSTSTROKE; MECHANICS; COST;
D O I
10.1186/s12984-021-00943-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Autonomous exoskeletons will need to be useful at a variety of walking speeds, but it is unclear how optimal hip-knee-ankle exoskeleton assistance should change with speed. Biological joint moments tend to increase with speed, and in some cases, optimized ankle exoskeleton torques follow a similar trend. Ideal hip-knee-ankle exoskeleton torque may also increase with speed. The purpose of this study was to characterize the relationship between walking speed, optimal hip-knee-ankle exoskeleton assistance, and the benefits to metabolic energy cost. Methods We optimized hip-knee-ankle exoskeleton assistance to reduce metabolic cost for three able-bodied participants walking at 1.0 m/s, 1.25 m/s and 1.5 m/s. We measured metabolic cost, muscle activity, exoskeleton assistance and kinematics. We performed Friedman's tests to analyze trends across walking speeds and paired t-tests to determine if changes from the unassisted conditions to the assisted conditions were significant. Results Exoskeleton assistance reduced the metabolic cost of walking compared to wearing the exoskeleton with no torque applied by 26%, 47% and 50% at 1.0, 1.25 and 1.5 m/s, respectively. For all three participants, optimized exoskeleton ankle torque was the smallest for slow walking, while hip and knee torque changed slightly with speed in ways that varied across participants. Total applied positive power increased with speed for all three participants, largely due to increased joint velocities, which consistently increased with speed. Conclusions Exoskeleton assistance is effective at a range of speeds and is most effective at medium and fast walking speeds. Exoskeleton assistance was less effective for slow walking, which may explain the limited success in reducing metabolic cost for patient populations through exoskeleton assistance. Exoskeleton designers may have more success when targeting activities and groups with faster walking speeds. Speed-related changes in optimized exoskeleton assistance varied by participant, indicating either the benefit of participant-specific tuning or that a wide variety of torque profiles are similarly effective.
引用
收藏
页数:12
相关论文
共 35 条
  • [1] A soft robotic exosuit improves walking in patients after stroke
    Awad, Louis N.
    Bae, Jaehyun
    O'Donnell, Kathleen
    De Rossi, Stefano M. M.
    Hendron, Kathryn
    Sloot, Lizeth H.
    Kudzia, Pawel
    Allen, Stephen
    Holt, Kenneth G.
    Ellis, Terry D.
    Walsh, Conor J.
    [J]. SCIENCE TRANSLATIONAL MEDICINE, 2017, 9 (400)
  • [2] PACE OF LIFE
    BORNSTEIN, MH
    BORNSTEIN, HG
    [J]. NATURE, 1976, 259 (5544) : 557 - 559
  • [3] BROCKWAY JM, 1987, HUM NUTR-CLIN NUTR, V41C, P463
  • [4] A hip-knee-ankle exoskeleton emulator for studying gait assistance
    Bryan, Gwendolyn M.
    Franks, Patrick W.
    Klein, Stefan C.
    Peuchen, Robert J.
    Collins, Steven H.
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2021, 40 (4-5) : 722 - 746
  • [5] C Zhang C., 2017, Bioinspired Legged Locomotion: Models, Concepts, Control and Applications, V1st, P347, DOI DOI 10.1016/B978-0-12-803766-9.00007-5
  • [6] Effect of Hip Assistance Modes on Metabolic Cost of Walking With a Soft Exoskeleton
    Cao, Wujing
    Chen, Chunjie
    Hu, Hongyue
    Fang, Kai
    Wu, Xinyu
    [J]. IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2021, 18 (02) : 426 - 436
  • [7] MECHANICAL WORK IN TERRESTRIAL LOCOMOTION - 2 BASIC MECHANISMS FOR MINIMIZING ENERGY-EXPENDITURE
    CAVAGNA, GA
    HEGLUND, NC
    TAYLOR, CR
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (05): : R243 - R261
  • [8] Reducing the energy cost of human walking using an unpowered exoskeleton
    Collins, Steven H.
    Wiggin, M. Bruce
    Sawicki, Gregory S.
    [J]. NATURE, 2015, 522 (7555) : 212 - +
  • [9] Filtering the surface EMG signal: Movement artifact and baseline noise contamination
    De Luca, Carlo J.
    Gilmore, L. Donald
    Kuznetsov, Mikhail
    Roy, Serge H.
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (08) : 1573 - 1579
  • [10] Human-in-the-loop optimization of hip assistance with a soft exosuit during walking
    Ding, Ye
    Kim, Myunghee
    Kuindersma, Scott
    Walsh, Conor J.
    [J]. SCIENCE ROBOTICS, 2018, 3 (15)