Ultrasound Contrast Plane Wave Imaging with Higher CTR based on Pulse Inversion Bubble Wavelet Transform

被引:8
作者
Wang, Diya [1 ]
Yang, Xuan [1 ]
Wan, Jinjin [1 ]
Jing, Bowen [1 ]
Zhang, Lei [1 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Biomed Engn, Sch Life Sci & Technol, Key Lab Biomed Informat Engn,Minist Educ, Xian 710049, Peoples R China
来源
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2014年
关键词
plane wave imaging; ultrasound contrast imaging; bubble wavele; AGENTS;
D O I
10.1109/ULTSYM.2014.0437
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although ultrasound contrast plane wave imaging can avoid the repeated disruption and capture the transient spatial distribution of microbubbles, it is still limited by lower contrast-to-tissue ratio (CTR) due to low negative peak pressure and lacks of transmit focus. The purpose of this paper was to develop an ultrasound contrast plane wave imaging method combined with pulse inversion bubble wavelet transform imaging (PIWI) technique to improve the CTR of plane wave images. First, a pair of "bubble wavelets" was constructed by microbubbles scattering echoes predicted by modified Herring equation driven by two inverted plane waves. Next, the original echoes from such plane waves were performed by bubble wavelet correlation analysis. Then, such echoes replaced by the maximal wavelet correlation coefficients were summed to distinguish echoes of microbubbles and tissues. In vivo rabbit kidney experiments, the CTR of plane wave imaging was improved to 15.19 dB by PIWI technique without the sacrifice of image frame, which was larger 4.48 +/- 0.96 dB than that of raw images. In summary, this method could contribute to plane wave imaging by allowing the continuous transient monitoring of the accumulation of microbubbles with higher CTR.
引用
收藏
页码:1762 / 1765
页数:4
相关论文
共 7 条
[1]  
Couture O., 2012, ULTRASONICS FERROELE, V59
[2]   Detection procedures of ultrasound contrast agents [J].
de Jong, N ;
Frinking, PJA ;
Bouakaz, A ;
Ten Cate, FJ .
ULTRASONICS, 2000, 38 (1-8) :87-92
[3]   Complexity measures of brain wave dynamics [J].
Gao, Jianbo ;
Hu, Jing ;
Tung, Wen-wen .
COGNITIVE NEURODYNAMICS, 2011, 5 (02) :171-182
[4]   PARAMETRIC PERFUSION IMAGING BASED ON LOW-COST ULTRASOUND PLATFORM [J].
Gu, Xiaolin ;
Zhong, Hui ;
Wan, Mingxi ;
Hu, Xiaowen ;
Lv, Dan ;
Shen, Liang ;
Zhang, Xiaomei .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (01) :130-144
[5]  
Morgan KE, 2000, IEEE T ULTRASON FERR, V47, P1494, DOI 10.1109/58.883539
[6]   Pulse inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents [J].
Simpson, DH ;
Chin, CT ;
Burns, PN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (02) :372-382
[7]   ULTRASOUND CONTRAST IMAGING BASED ON A NOVEL ALGORITHM COMBINED PULSE INVERSION WITH WAVELET TRANSFORM [J].
Zhao, Xiaoyan ;
Zhong, Hui ;
Wan, Mingxi ;
Shen, Liang .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (08) :1292-1305