Medical beam monitor -: Pre-clinical evaluation and future applications

被引:5
作者
Frais-Koelbl, Helmut [1 ]
Griesmayer, Erich
Schreiner, Thomas
Georg, Dietmar
Pernegger, Heinz
机构
[1] Univ Appl Sci, Wiener Neustadt, Austria
[2] Fotec Forsch & Technol Transfer GmbH, Wiener Neustadt, Austria
[3] Med Univ, Dept Radiotherapy Radiobiol, Vienna, Austria
[4] CERN, Geneva, Switzerland
关键词
CVD diamond; semiconductor radiation detectors; radiotherapy dosimetry; ion therapy;
D O I
10.1016/j.nima.2007.07.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Future medical ion beam applications for cancer therapy which are based on scanning technology will require advanced beam diagnostics equipment. For a precise analysis of beam parameters we want to resolve time structures in the range of microseconds to nanoseconds. A prototype of an advanced beam monitor was developed by the University of Applied Sciences Wiener Neustadt and its research subsidiary Fotec in co-operation with CERN RD42, Ohio State University and the Jozef Stefan Institute in Ljubljana. The detector is based on polycrystalline Chemical Vapor Deposition (pCVD) diamond substrates and is equipped with readout electronics up to 2GHz analog bandwidth. In this paper we present the design of the pCVD-detector system and results of tests performed in various particle accelerator based facilities. Measurements performed in clinical high energy photon beams agreed within 1.2% with results obtained by standard ionization chambers. (C) 2007 Published by Elsevier B.V.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 10 条
  • [1] Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities
    Crespo, P
    Barthel, T
    Frais-Kölbl, H
    Griesmayer, E
    Heidel, K
    Parodi, K
    Pawelke, J
    Enghardt, W
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 980 - 987
  • [2] A preliminary dosimetric characterization of chemical vapor deposition diamond detector prototypes in photon and electron radiotherapy beams
    Fidanzio, A
    Azario, L
    Kalish, R
    Avigal, Y
    Conte, G
    Ascarelli, P
    [J]. MEDICAL PHYSICS, 2005, 32 (02) : 389 - 395
  • [3] Photon and electron beam dosimetry with a CVD diamond detector
    Fidanzio, A
    Azario, L
    Viola, P
    Ascarelli, P
    Cappelli, E
    Conte, G
    Piermattei, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 524 (1-3) : 115 - 123
  • [4] A fast low-noise charged-particle CVD diamond detector
    Frais-Kölbl, H
    Griesmayer, E
    Kagan, H
    Pernegger, H
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3833 - 3837
  • [5] ATLAS diamond Beam Condition Monitor
    Gorisek, A.
    Cindro, V.
    Dolenc, I.
    Frais-Koelbl, H.
    Griesmayer, E.
    Kagan, H.
    Korpar, S.
    Kramberger, G.
    Mandic, I.
    Meyer, M.
    Mikuz, M.
    Pernegger, H.
    Smith, S.
    Trischuk, W.
    Weilhammer, P.
    Zavrtanik, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01) : 67 - 69
  • [6] Diamond pad detector telescope for beam conditions and luminosity monitoring in ATLAS
    Mikuz, M.
    Cindro, V.
    Dolenc, I.
    Frais-Koelbl, H.
    Gorisek, A.
    Griesmayer, E.
    Kagan, H.
    Kramberger, G.
    Mandic, I.
    Niegl, M.
    Pernegger, H.
    Trischuk, W.
    Wellhammer, P.
    Zavrtanik, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02) : 788 - 794
  • [7] A design of a rotating gantry for non-symmetric ion-therapy beams
    Pavlovic, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 438 (2-3) : 548 - 559
  • [8] Oblique gantry - an alternative solution for a beam delivery system for heavy-ion cancer therapy
    Pavlovic, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (2-3) : 454 - 466
  • [9] Beam-optics study of the gantry beam delivery system for light-ion cancer therapy
    Pavlovic, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3) : 439 - 454
  • [10] Design and test of a high-speed single-particle beam monitor
    Pernegger, H
    Frais-Kölbl, H
    Griesmayer, E
    Kagan, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2) : 108 - 114