A screen-printed Ag/AgCl reference electrode with long-term stability for electroanalytical applications

被引:31
作者
Dawkins, Rebecca C. [1 ,2 ]
Wen, Dingchen [1 ]
Hart, Judy N. [2 ]
Vepsalainen, Mikko [1 ,3 ]
机构
[1] CSIRO, Mineral Resources, Private Bag 10, Clayton, Vic 3169, Australia
[2] UNSW Sydney, Sch Mat Sci & Engn, Sydney, NSW 2052, Australia
[3] VFT Tech Res Ctr Finland, POB 1000, FI-02044 Espoo, Finland
关键词
Screen printed electrodes; Reference electrode; PDMS; Electroanalytical sensors; Silver/silver chloride; MINIATURIZED REFERENCE ELECTRODES; FABRICATION; WATER; PH;
D O I
10.1016/j.electacta.2021.139043
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Low-cost sensor arrays are required to allow for real-time, in situ electrochemical monitoring using Internet-of-Things (IoT) systems; however, they are currently not practical due to a lack of stable, mass-producible reference electrodes. To solve this problem, in this work we have developed a screen-printed Ag/AgCl true reference electrode with an offset salt reservoir on a flexible substrate for use in disposable, low-cost sensor arrays. A KCI-containing poly(vinyl acetate) ink was prepared as the solid-state electrolyte, and a PDMS junction membrane was deposited to suppress electrolyte leaching. The potentials of the electrodes with and without the electrolyte and junction membranes were measured versus a commercial saturated calomel reference electrode (SCE) in 0.1 M K2SO4 solution. Potential stability of -45.5 +/- 3 mV vs. SCE with low drift was maintained for up to 27 days for electrodes containing both the electrolyte and PDMS layers, compared to less than 1 day without the PDMS junction. The electrodes were found to be stable in solutions at different pH and were also insensitive to most interfering ionic species, including SO42-, I-, Br-, Cl-, F-, Na+, and K+, under continuous potential measurement with an impedance of similar to 15 k Omega at 106 Hz. The results demonstrate that the present printed reference electrodes are stable for an extended period and therefore well suited for use in electroanalytical systems for high volume IoT applications. (C) 2021 The Authors. Published by Elsevier Ltd.
引用
收藏
页数:10
相关论文
共 44 条
[31]   Long-term equilibrium potential and electrochemical impedance study of Ag/AgCl electrodes used in Harned Cell measurements of pH [J].
Brown, Richard J. C. ;
Brewer, Paul J. ;
Brett, Dan J. L. .
ACCREDITATION AND QUALITY ASSURANCE, 2009, 14 (03) :139-145
[32]   Long-term equilibrium potential and electrochemical impedance study of Ag/AgCl electrodes used in Harned Cell measurements of pH [J].
Richard J. C. Brown ;
Paul J. Brewer ;
Dan J. L. Brett .
Accreditation and Quality Assurance, 2009, 14 :139-145
[33]   Method development for the determination of arsenic by sequential injection/anodic stripping voltammetry using long-lasting gold-modified screen-printed carbon electrode [J].
Punrat, Eakkasit ;
Chuanuwatanakul, Suchada ;
Kaneta, Takashi ;
Motomizu, Shoji ;
Chailapakul, Orawon .
TALANTA, 2013, 116 :1018-1025
[34]   Fabrication and Characterization of a Stabilized Thin Film Ag/AgCl Reference Electrode Modified with Self-Assembled Monolayer of Alkane Thiol Chains for Rapid Biosensing Applications [J].
Rahman, Tanzilur ;
Ichiki, Takanori .
SENSORS, 2017, 17 (10)
[35]   Stability of a Ag/AgCl Reference Electrode Equipped with an Ionic Liquid Salt Bridge Composed of 1-Methyl-3-octylimidazolium Bis(trifluoromethanesulfonyl)amide in Potentiometry of pH Standard Buffers [J].
Shibata, Manabu ;
Yamanuki, Mikito ;
Iwamoto, Yasukazu ;
Nomura, Satoshi ;
Kakiuchi, Takashi .
ANALYTICAL SCIENCES, 2010, 26 (11) :1203-1206
[36]   Long-term stability and durability of direct-ink-writing 3D-printed sensors: challenges, strategies and prospects [J].
Zhao, Yuxiang ;
Yu, Peishi ;
Tao, Yin ;
Zhang, Xin ;
Li, Maoyang ;
Xu, Wen ;
Zhao, Junhua .
VIRTUAL AND PHYSICAL PROTOTYPING, 2025, 20 (01)
[37]   A bioinspired lubricant infused surface with transparency, hot liquid boiling resistance and long-term stability for food applications [J].
Wang, Daheng ;
Guo, Zhiguang .
NEW JOURNAL OF CHEMISTRY, 2020, 44 (11) :4529-4537
[38]   Electrochemical removal of nitrate using Co/Ni bimetallic electrode: High N2 selectivity and long-term stability [J].
Chen, Zhuang ;
Zhang, Yimei ;
Cao, Ting ;
Yao, Kaiwen .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 179 :384-393
[39]   Highly conductive copper films based on submicron copper particles/copper complex inks for printed electronics: Microstructure, resistivity, oxidation resistance, and long-term stability [J].
Li, Wanli ;
Li, Lingying ;
Gao, Yue ;
Hu, Dawei ;
Li, Cai-Fu ;
Zhang, Hao ;
Jiu, Jinting ;
Nagao, Shijo ;
Suganuma, Katsuaki .
JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 732 :240-247
[40]   The stability of hydrogen evolution activity and corrosion behavior of porous Ni3Al-Mo electrode in alkaline solution during long-term electrolysis [J].
Wu, Liang ;
He, Yuehui ;
Lei, Ting ;
Nan, Bo ;
Xu, Nanping ;
Zou, Jin ;
Huang, Baiyun ;
Liu, C. T. .
ENERGY, 2014, 67 :19-26