Correlates of clinical Restenosis following intracoronary implantation of drug-eluting stents

被引:34
作者
Roy, Probal [1 ]
Okabe, Teruo [1 ]
Slottow, Tina L. Pinto [1 ]
Steinberg, Daniel H. [1 ]
Smith, Kimberly [1 ]
Torguson, Rebecca [1 ]
Xue, Zhenyi [1 ]
Gevorkian, Natalie [1 ]
Satler, Lowell F. [1 ]
Kent, Kenneth M. [1 ]
Suddath, William [1 ]
Pichard, Augusto D. [1 ]
Waksman, Ron [1 ]
机构
[1] Washington Hosp Ctr, Div Cardiol, Washington, DC 20010 USA
关键词
D O I
10.1016/j.amjcard.2007.04.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite significant decreases in restenosis and repeated intervention achieved using drug-eluting stents (DESs), the benefit has not been homogenous across all patient and lesion subsets. Identification of correlates of DES restenosis may allow a differing management approach and lead to improved patient outcomes. The study population consisted of 3,535 consecutive patients (5,046 lesions) who underwent successful sirolimus- or paclitaxel-eluting stent implantation for >= 1 native coronary artery or bypass graft lesion from April 2003 to September 2006. From this cohort, 197 patients (237 lesions) were identified to have in-stent restenosis (ISR) requiring revascularization within 12 months of stent implantation. This group was compared with the remainder of the patient population. Logistic regression analysis was performed to identify independent predictors of DES ISR. Independent correlates of DES ISR using multivariate analysis included both clinical and procedural factors. Clinical predictors were age, hypertension, and unstable angina. Procedural predictors were left anterior descending artery intervention, number of stents implanted, stented length/lesion, and lack of intravascular ultrasound guidance. Implantation of >= 3 stents was associated with a significantly higher restenosis risk (9.7% vs 5.1%; p = 0.0003). A 10-mm increase in stented length was associated with an adjusted odds ratio of 1.18 (95% confidence interval 1.03 to 1.35). Diabetes, stent diameter, and stent type were found not to be predictive of DES ISR. In conclusion, correlates of DES ISR included both clinical and procedural factors. Limiting the number of stents and stented length, in addition to intravascular ultrasound guidance, may minimize DES ISR. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:965 / 969
页数:5
相关论文
共 27 条
[1]   Optimal geometry is still important with sirolimus-eluting stents: Incomplete stent expansion as a risk for target lesion revascularization [J].
Ako, J ;
Morino, Y ;
Terashima, M ;
Honda, Y ;
Sonoda, S ;
Leon, MB ;
Moses, JW ;
Yock, PG ;
Fitzgerald, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :84A-84A
[2]   Full metal jacket (stented length ≥64 mm) using drug-eluting stents for de novo coronary artery lesions [J].
Aoki, J ;
Ong, ATL ;
Granillo, GAR ;
McFadden, EP ;
van Mieghem, CAG ;
Valgimigli, M ;
Tsuchida, K ;
Sianos, G ;
Regar, E ;
de Jaegere, PPT ;
van der Giessen, WJ ;
de Feyter, PJ ;
van Domburg, RT ;
Serruys, PW .
AMERICAN HEART JOURNAL, 2005, 150 (05) :994-999
[3]   Incidence and predictors of restenosis after sirolimus-eluting stent implantation in high-risk patients [J].
Berenguer, A ;
Mainar, V ;
Bordes, P ;
Valencia, J ;
Gómez, S ;
Lozano, T .
AMERICAN HEART JOURNAL, 2005, 150 (03) :536-542
[4]   Stent thrombosis late after implantation of first-generation drug-eluting stents - A cause for concern [J].
Camenzind, Edoardo ;
Steg, P. Gabriel ;
Wijns, William .
CIRCULATION, 2007, 115 (11) :1440-1455
[5]   Clinical restenosis after coronary stenting: Perspectives from multicenter clinical trials [J].
Cutlip, DE ;
Chauhan, MS ;
Baim, DS ;
Ho, KKL ;
Popma, JJ ;
Carrozza, JP ;
Cohen, DJ ;
Kuntz, RE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (12) :2082-2089
[6]  
Fitzgerald PJ, 2000, CIRCULATION, V102, P523
[7]   Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis [J].
Fujii, K ;
Mintz, GS ;
Kobayashi, Y ;
Carlier, SG ;
Takebayashi, H ;
Yasuda, T ;
Moussa, I ;
Dangas, G ;
Mehran, R ;
Lansky, AJ ;
Reyes, A ;
Kreps, E ;
Collins, M ;
Colombo, A ;
Stone, GW ;
Teirstein, PS ;
Leon, MB ;
Moses, JW .
CIRCULATION, 2004, 109 (09) :1085-1088
[8]   Overdilation of Cypher 3.0 mm 6 cells stent: Clinical consequences [J].
Iakovou, I ;
Stankovic, G ;
Orlic, D ;
Vitrella, G ;
Sangiorgi, G ;
Corvaja, N ;
Chieffo, A ;
Michev, L ;
Airoldi, F ;
Spanos, V ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :45A-45A
[9]   Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents [J].
Kastrati, A ;
Dibra, A ;
Mehilli, J ;
Mayer, S ;
Pinieck, S ;
Pache, J ;
Dirschinger, J ;
Schöming, A .
CIRCULATION, 2006, 113 (19) :2293-2300
[10]   Predictive factors of restenosis after coronary stent placement [J].
Kastrati, A ;
Schomig, A ;
Elezi, S ;
Schuhlen, H ;
Dirschinger, J ;
Hadamitzky, M ;
Wehinger, A ;
Hausleiter, J ;
Walter, H ;
Neumann, FJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) :1428-1436