Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning

被引:65
作者
Gabriele, Michelle L.
Ishikawa, Hiroshi
Wollstein, Gadi
Bilonick, Richard A.
Kagemann, Larry
Wojtkowski, Maciej
Srinivasan, Vivek J.
Fujimoto, James G.
Duker, Jay S.
Schuman, Joel S.
机构
[1] Univ Pittsburgh, Sch Med, UPMC Eye Ctr, Dept Ophthalmol,Eye & Ear Inst, Pittsburgh, PA 15213 USA
[2] MIT, Dept Elect Engn, Cambridge, MA 02139 USA
[3] MIT, Comp Sci & Res Lab Electron, Cambridge, MA 02139 USA
[4] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
[5] Tufts Univ, Sch Med, New England Med Ctr, New England Eye Ctr, Boston, MA 02111 USA
关键词
D O I
10.1167/iovs.06-1416
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the retinal nerve fiber layer (RNFL) thickness profile in the peripapillary region of healthy eyes. METHODS. Three-dimensional, Fourier/spectral domain optical coherence tomography (OCT) data were obtained as raster scan data (512 x 180 axial scans in a 6 x 6-mm region centered on the optic nerve head [ONH]) with high-speed, ultrahigh-resolution OCT (hsUHR-OCT) from 12 healthy subjects. RNFL thickness was measured on this three-dimensional data set with an in-house software program. The disc margin was defined subjectively in each image and RNFL thickness profiles relative to distance from the disc center were computed for quadrants and clock hours. A mixed-effects model was used to characterize the slope of the profiles. RESULTS. Thickness profiles in the superior, inferior, and temporal quadrants showed an initial increase in RNFL thickness, an area of peak thickness, and a linear decrease as radial distance from the disc center increased. The nasal quadrant showed a constant linear decay without the initial RNFL thickening. A mixed-effects model showed that the slopes of the inferior, superior, and nasal quadrants differed significantly from the temporal slope (P = 0.0012, P = 0.0003, and P = 0.0004, respectively). CONCLUSIONS. RNFL thickness is generally inversely related to the distance from the ONH center in the peripapillary region of healthy subjects, as determined by hsUHR-OCT. However, several areas showed an initial increase in RNFL, followed by a peak and a gradual decrease.
引用
收藏
页码:3154 / 3160
页数:7
相关论文
共 27 条
[1]  
AIRAKSINEN PJ, 1984, AM J OPHTHALMOL, V98, P566, DOI 10.1016/0002-9394(84)90242-3
[2]  
Bayraktar S, 2001, J GLAUCOMA, V10, P163
[3]   Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[4]   Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes [J].
Carpineto, P ;
Ciancaglini, M ;
Zuppardi, E ;
Falconio, G ;
Doronzo, E ;
Mastropasqua, L .
OPHTHALMOLOGY, 2003, 110 (01) :190-195
[5]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[6]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[7]   Retinal nerve fiber layer thickness In human eyes [J].
Dichtl, A ;
Jonas, JB ;
Naumann, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (06) :474-479
[8]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[9]  
HOYT WF, 1973, INVEST OPHTH VISUAL, V12, P814
[10]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894