Transforming a pre-existing MRI environment into an interventional cardiac MRI suite

被引:11
作者
Bijvoet, Geertruida P. [1 ,2 ,3 ]
Holtackers, Robert J. [1 ,4 ]
Smink, Jouke [5 ]
Lloyd, Tom [6 ]
van den Hombergh, Cristy L. M. [7 ]
Debie, Luuk J. B. M. [2 ]
Wildberger, Joachim E. [1 ,4 ]
Vernooy, Kevin [1 ,2 ,3 ]
Mihl, Casper [1 ,4 ]
Chaldoupi, Sevasti-Maria [2 ,3 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Dept Cardiol, Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Cardiol, Maastricht, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Cardiol, Nijmegen, Netherlands
[4] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, Maastricht, Netherlands
[5] Dept Clin Res, Philips Hlthcare, Best, Netherlands
[6] Dept Clin Res, Imricor Med Syst, Burnsville, MN USA
[7] Maastricht Univ, Med Ctr, Dept Anaesthesiol, Maastricht, Netherlands
关键词
basic; atrial fibrillation; atrial arrhythmias; clinical; cardiac anatomy; catheter ablation-atrial flutter; electrophysiology-atrial arrhythmias; noninvasive techniques-MRI; CATHETER TRACKING; ELECTROPHYSIOLOGY; ABLATION; GUIDANCE;
D O I
10.1111/jce.15128
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To illustrate the practical and technical challenges along with the safety aspects when performing MRI-guided electrophysiological procedures in a pre-existing diagnostic magnetic resonance imaging (MRI) environment. Methods and Results A dedicated, well-trained multidisciplinary interventional cardiac MRI team (iCMR team), consisting of electrophysiologists, imaging cardiologists, radiologists, anaesthesiologists, MRI physicists, electrophysiological (EP) and MRI technicians, biomedical engineers, and medical instrumentation technologists is a prerequisite for a safe and feasible implementation of CMR-guided electrophysiological procedures (iCMR) in a pre-existing MRI environment. A formal dry run "mock-up" to address the entire spectrum of technical, logistic, and safety issues was performed before obtaining final approval of the Board of Directors. With this process we showed feasibility of our workflow, safety protocol, and bailout procedures during iCMR outside the conventional EP lab. The practical aspects of performing iCMR procedures in a pre-existing MRI environment were addressed and solidified. Finally, the influence on neighbouring MRI scanners was evaluated, showing no interference. Conclusion Transforming a pre-existing diagnostic MRI environment into an iCMR suite is feasible and safe. However, performing iCMR procedures outside the conventional fluoroscopic lab, poses challenges with technical, practical, and safety aspects that need to be addressed by a dedicated multi-disciplinary iCMR team.
引用
收藏
页码:2090 / 2096
页数:7
相关论文
共 10 条
[1]  
Chubb H, 2017, ARRHYTH ELECTROPHYSI, V6, P85, DOI [10.15420/aer.2017.1.2, 10.15420/aer.2017:1:2]
[2]  
Chubb Henry, 2017, JACC Clin Electrophysiol, V3, P89, DOI 10.1016/j.jacep.2016.07.005
[3]   MR Imaging-guided Electrophysiological Ablation Studies in Humans with Passive Catheter Tracking: Initial Results [J].
Grothoff, Matthias ;
Piorkowski, Christopher ;
Eitel, Charlotte ;
Gaspar, Thomas ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Hoffmann, Janine ;
Hildebrand, Lysann ;
Wedan, Steve ;
Lloyd, Thomas ;
Sunnarborg, Daniel ;
Schnackenburg, Bernhard ;
Hindricks, Gerhard ;
Sommer, Philipp ;
Gutberlet, Matthias .
RADIOLOGY, 2014, 271 (03) :695-702
[4]   Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series [J].
Hilbert, Sebastian ;
Sommer, Philipp ;
Gutberlet, Matthias ;
Gaspar, Thomas ;
Foldyna, Borek ;
Piorkowski, Christopher ;
Weiss, Steffen ;
Lloyd, Thomas ;
Schnackenburg, Bernhard ;
Krueger, Sascha ;
Fleiter, Christian ;
Paetsch, Ingo ;
Jahnke, Cosima ;
Hindricks, Gerhard ;
Grothoff, Matthias .
EUROPACE, 2016, 18 (04) :572-577
[5]   ACR guidance document on MR safe practices: 2013 [J].
Kanal, Emanuel ;
Barkovich, A. James ;
Bell, Charlotte ;
Borgstede, James P. ;
Bradley, William G., Jr. ;
Froelich, Jerry W. ;
Gimbel, J. Rod ;
Gosbee, John W. ;
Kuhni-Kaminski, Ellisa ;
Larson, Paul A. ;
Lester, James W., Jr. ;
Nyenhuis, John ;
Schaefer, Daniel Joe ;
Sebek, Elizabeth A. ;
Weinreb, Jeffrey ;
Wilkoff, Bruce L. ;
Woods, Terry O. ;
Lucey, Leonard ;
Hernandez, Dina .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (03) :501-530
[6]  
Nederlandse Norm (NEN) and International Electrotechnical Commission (IEC), 2020, ELECT INSTALLATIONS
[7]  
Nederlandse Vereniging voor Medsche Microbiologie, 2020, RICHTL LUCHTB OP BEH
[8]   Clinical workflow and applicability of electrophysiological cardiovascular magnetic resonance-guided radiofrequency ablation of isthmus-dependent atrial flutter [J].
Paetsch, Ingo ;
Sommer, Philipp ;
Jahnke, Cosima ;
Hilbert, Sebastian ;
Loebe, Susanne ;
Schoene, Katharina ;
Oebel, Sabrina ;
Krueger, Sascha ;
Weiss, Steffen ;
Smink, Jouke ;
Lloyd, Tom ;
Hindricks, Gerhard .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 (02) :147-156
[9]   Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans [J].
Sommer, Philipp ;
Grothoff, Matthias ;
Eitel, Charlotte ;
Gaspar, Thomas ;
Piorkowski, Christopher ;
Gutberlet, Matthias ;
Hindricks, Gerhard .
EUROPACE, 2013, 15 (01) :101-108
[10]   Guidelines for the safe provision of anaesthesia in magnetic resonance units 2019 Guidelines from the Association of Anaesthetists and the Neuro Anaesthesia and Critical Care Society of Great Britain and Ireland [J].
Wilson, S. R. ;
Shinde, S. ;
Appleby, I ;
Boscoe, M. ;
Conway, D. ;
Dryden, C. ;
Ferguson, K. ;
Gedroyc, W. ;
Kinsella, S. M. ;
Nathanson, M. H. ;
Thorne, J. ;
White, M. ;
Wright, E. .
ANAESTHESIA, 2019, 74 (05) :638-650