Monte Carlo modeling of a novel brachytherapy applicator for rectal cancer treatment using GEANT4

被引:2
作者
Poon, E
DeBlois, F
Devic, S
Vuong, T
Verhaegen, F
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[2] McGill Univ, Hlth Ctr Oncol, Montreal, PQ, Canada
关键词
D O I
10.1016/S0167-8140(05)81015-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S27 / S28
页数:2
相关论文
共 50 条
  • [31] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [32] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [33] IMRT treatment Monitor Unit verification using absolute calibrated BEAMnrc and Geant4 Monte Carlo simulations
    Oborn, B. M.
    Williams, M.
    Bailey, M.
    Carolan, M. G.
    [J]. XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [34] Evaluation of organ doses following high dose rate (HDR) brachytherapy of breast cancer: a Geant4 Monte Carlo simulation study
    Aidil, M. S.
    Hashikin, N. A. A.
    Yeong, C. H.
    Guatelli, S.
    Ng, K. H.
    Malaroda, A.
    Rosenfeld, A. B.
    Perkins, A. C.
    [J]. 18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [35] Cancer risk estimation in Digital Breast Tomosynthesis using GEANT4 Monte Carlo simulations and voxel phantoms
    Ferreira, P.
    Baptista, M.
    Di Maria, S.
    Vaz, P.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 717 - 723
  • [36] Dosimetric comparison between different radiotherapy protocols for prostate cancer using Geant4 Monte Carlo simulation
    Syahir, M. K.
    Fahmi, M. R.
    Hashikin, N. A. A.
    [J]. 11TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS (ISMP) 2019, 2020, 1497
  • [37] Characterization of HPGe gamma spectrometers by geant4 Monte Carlo simulations
    Szentmiklosi, Laszlo
    Belgya, Tamas
    Maroti, Boglarka
    Kis, Zoltan
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) : 553 - 558
  • [38] A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) : 5203 - 5219
  • [39] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Bardane, Adil
    Tajmouaati, Jaouad
    Maghnouj, Abdelmajid
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 58 - 62
  • [40] A GEANT4 Monte-Carlo simulation code for precision β spectroscopy
    Wauters, F.
    Kraev, I.
    Zakoucky, D.
    Beck, M.
    Golovko, V. V.
    Kozlov, V. Yu.
    Phalet, T.
    Tandecki, M.
    Traykov, E.
    Van Gorp, S.
    Severijns, N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3) : 156 - 164