Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC)

被引:19
|
作者
Kleinecke, Caroline [1 ]
Yu, Jiangtao [1 ]
Neef, Philip [2 ,3 ]
Buffle, Eric [4 ]
de Marchi, Stefano [4 ]
Fuerholz, Monika [4 ]
Nietlispach, Fabian [5 ,6 ]
Valgimigli, Marco [4 ]
Streit, Samuel R. [4 ]
Fankhauser, Mate [4 ]
Duenninger, Erich [1 ]
Windecker, Stephan [4 ]
Meier, Bernhard [4 ]
Gloekler, Steffen [2 ]
机构
[1] REGIOMED Klinikum Lichtenfels, Dept Cardiol, Lichtenfels, Germany
[2] Schwarzwald Baar Klinikum, Dept Cardiol, Klinikstr 11, D-78052 Villingen Schwenningen, Germany
[3] Univ Bern, Fac Med, Bern, Switzerland
[4] Univ Hosp Bern, Cardiovasc Dept, Cardiol, Bern, Switzerland
[5] Univ Zurich Hosp, Dept Cardiol, Zurich, Switzerland
[6] Hirslanden Klin Pk, Cardiovasc Ctr Zurich, Zurich, Switzerland
来源
EUROPACE | 2020年 / 22卷 / 06期
关键词
Atrial fibrillation; Stroke prevention; Left atrial appendage closure; Watchman; Amplatzer; Anticoagulation; END-POINT DEFINITIONS; OCCLUSION; STROKE; FIBRILLATION; PREVENTION;
D O I
10.1093/europace/euaa001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This study compares clinical outcomes of Watchman vs. Amplatzer devices for left atrial appendage closure (LAAC). Methods and results Of two real-world registries, the Watchman registry Lichtenfels, Germany, and the Amplatzer registry Bern-Zurich, Switzerland, 303 and 333 consecutive patients, respectively, were included. After a 1:1 propensity score matching, 266 vs. 266 patients were compared by use of the predefined primary efficacy endpoint of stroke, systemic embolism and cardiovascular/unexplained death, the primary safety endpoint of major peri-procedural complications and major bleeding events at follow-up, and the combined hazard endpoint, a composite of all above-mentioned hazards. Mean age was 75.37.8 (Watchman) vs. 75.1 +/- 9.9 (Amplatzer) years, CHA(2)DS(2)-VASc score 4.5 +/- 1.7 vs. 4.5 +/- 1.5, and HAS-BLED score 3.2 +/- 1.0 vs. 3.2 +/- 1.0. At a mean follow-up of 2.4 +/- 1.3 vs. 2.5 +/- 1.5 years and 1.322 patient-years, the primary endpoints of efficacy [40/646, 6.2% [Watchman] vs. 43/676, 6.4% [Amplatzer]; hazard ratio (HR), 1.02; 95% confidence interval (CI), 0.66-1.58; P=0.92] and safety (33/646, 5.1% vs. 30/676, 4.4%; HR, 0.57; 95% CI, 0.29-1.11; P=0.10), as well as the combined hazard endpoint (69/646, 10.7% vs. 66/676, 9.8%; HR, 0.80; 95% CI, 0.55-1.12; P=0.26) were similar for both groups. Conclusion This study suggests comparable efficacy and safety of the Watchman and Amplatzer devices.
引用
收藏
页码:916 / 923
页数:8
相关论文
共 50 条
  • [1] Late clinical outcomes of lambre versus amplatzer occluders for left atrial appendage closure
    Schnupp, Steffen
    Liu, Xiao-Xia
    Buffle, Eric
    Gloekler, Steffen
    Mohrez, Yamen
    Cheikh-Ibrahim, Mohammad
    Allakkis, Wasim
    Brachmann, Johannes
    Park, Jai-Wun
    Kleinecke, Caroline
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (04) : 934 - 942
  • [2] Long-term clinical outcomes of Amplatzer cardiac plug versus Amulet occluders for left atrial appendage closure
    Kleinecke, Caroline
    Cheikh-Ibrahim, Mohammad
    Schnupp, Steffen
    Fankhauser, Mate
    Nietlispach, Fabian
    Park, Jai-Wun
    Brachmann, Johannes
    Windecker, Stephan
    Meier, Bernhard
    Gloekler, Steffen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (03) : E324 - E331
  • [3] Combined atrial fibrillation ablation and left atrial appendage closure: Watchman vs. LAmbre devices
    Ke, Jin-Yan
    Jin, Lu-Shen
    Lin, Yuan-Nan
    Xu, Jing
    Liu, Wei-Ke
    Fu, Jia-Yang
    Li, Ling
    Chen, Yi-Lian
    Qiu, Yi-Xuan
    Li, Yue-Chun
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [4] Impact of conscious sedation and general anesthesia on periprocedural outcomes in Watchman left atrial appendage closure
    Kleinecke, Caroline
    Allakkis, Wasim
    Buffle, Eric
    Liu, Xiao-Xia
    Mohrez, Yamen
    Gloekler, Steffen
    Brachmann, Johannes
    Schnupp, Steffen
    Achenbach, Stephan
    Yu, Jiangtao
    CARDIOLOGY JOURNAL, 2021, 28 (04) : 519 - 527
  • [5] Watchman vs. Amulet for Left Atrial Appendage Closure: Current Evidence and Future Perspectives
    Frazzetto, Marco
    Sanfilippo, Claudio
    Costa, Giuliano
    Contrafatto, Claudia
    Giacalone, Chiara
    Scandura, Salvatore
    Castania, Giuseppe
    De Santis, Jessica
    Sanfilippo, Maria
    Di Salvo, Maria Elena
    Tamburino, Corrado
    Barbanti, Marco
    Grasso, Carmelo
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)
  • [6] Watchman FLX vs. Watchman 2.5 in a Dual-Center Left Atrial Appendage Closure Cohort: the WATCH-DUAL study
    Galea, Roberto
    Mahmoudi, Khalil
    Grani, Christoph
    Elhadad, Simon
    Huber, Adrian T.
    Heg, Dik
    Siontis, George C. M.
    Brugger, Nicolas
    Sebag, Frederic
    Windecker, Stephan
    Valgimigli, Marco
    Landolff, Quentin
    Roten, Laurent
    Amabile, Nicolas
    Raber, Lorenz
    EUROPACE, 2022, 24 (09): : 1441 - 1450
  • [7] Comparing safety and efficacy: MemoLefort versus watchman for left atrial appendage closure
    Li, Ling
    Qian, Sang
    Fu, Jia-Yang
    Wang, Zhe-Ning
    Jiang, Ting
    Lin, Yuan-Nan
    Yao, Tao
    Liu, Jing-Chen
    Pan, Yang-Qi
    Li, Yue-Chun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 398
  • [8] Amplatzer left atrial appendage closure: Single versus combined procedures
    Kleinecke, Caroline
    Buffle, Eric
    Link, Juergen
    Haener, Jonas
    Sedaghat, Alexander
    Galea, Roberto
    Streit, Samuel R.
    Windecker, Stephan
    Meier, Bernhard
    Gloekler, Steffen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (07) : E973 - E981
  • [9] Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation
    Gloekler, Steffen
    Shakir, Samera
    Doblies, Janosch
    Khattab, Ahmed A.
    Praz, Fabien
    Guerios, Enio
    Koermendy, Dezsoe
    Stortecky, Stefan
    Pilgrim, Thomas
    Buellesfeld, Lutz
    Wenaweser, Peter
    Windecker, Stephan
    Moschovitis, Aris
    Jaguszewski, Milosz
    Landmesser, Ulf
    Nietlispach, Fabian
    Meier, Bernhard
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (08) : 656 - 665
  • [10] Evaluation of the WATCHMAN left atrial appendage closure device
    Alli, Oluseun
    Holmes, David, Jr.
    EXPERT REVIEW OF MEDICAL DEVICES, 2014, 11 (06) : 541 - 551