Multi-detector row CT of thoracic disease with emphasis on 3D volume rendering and CT angiography

被引:98
作者
Lawler, LP [1 ]
Fishman, EK [1 ]
机构
[1] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
computed tomography (CT); angiography; clinical effectiveness; image processing; volume rendering; thorax; anatomy; CT;
D O I
10.1148/radiographics.21.5.g01se021257
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multi-detector row computed tomography (CT) with three-dimensional (3D) volume rendering provides a unique perspective on thoracic anatomy and disease. Multi-detector row CT allows shorter acquisition times, greater coverage, and superior image resolution. Three-dimensional volume rendering now permits real-time, interactive modification of relative pixel attenuation in an infinite number of planes and projections. In vascular imaging, this technique provides image quality that equals or surpasses that of conventional angiography. Its use has expanded to aid in diagnosis and surgical planning, often obviating conventional or digital angiography and reducing costs. It is reliable in depicting clot and the pulmonary vasculature and may also be used to evaluate thoracic venous anomalies (eg, pulmonary arteriovenous malformations) and to plan therapy. Airway imaging with multi-detector row CT with 3D volume rendering is particularly useful in the planning and follow-up of stent placement. In diffuse lung disease, this technique can increase nodule detection and help differentiate between small nodules and vessels. It is also helpful in imaging the musculoskeletal system and the thoracic cage. Multi-detector row CT with 3D volume rendering has enhanced the conventional roles of thoracic CT and challenged the supremacy of other imaging modalities. It will likely play a leading role in future radiologic research and practice.
引用
收藏
页码:1257 / 1273
页数:17
相关论文
共 58 条
[11]   Unsuspected pulmonary embolism: Prospective detection on routine helical CT scans [J].
Gosselin, MV ;
Rubin, GD ;
Leung, AN ;
Huang, J ;
Rizk, NW .
RADIOLOGY, 1998, 208 (01) :209-215
[12]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[13]   Pancreaticoduodenal arcades and dorsal pancreatic artery: Comparison of CT angiography with three-dimensional volume rendering, maximum intensity projection, and shaded-surface display [J].
Hong, KC ;
Freeny, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :925-931
[14]   Pediatric great vessel anomalies: Initial clinical experience with spiral CT angiography [J].
Hopkins, KL ;
Patrick, LE ;
Simoneaux, SF ;
Bank, ER ;
Parks, WJ ;
Smith, SS .
RADIOLOGY, 1996, 200 (03) :811-815
[15]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[16]   Renal artery stenosis: CT angiography - Comparison of real-time volume-rendering and maximum intensity projection algorithms [J].
Johnson, PT ;
Halpern, EJ ;
Kuszyk, BS ;
Heath, DG ;
Wechsler, RJ ;
Nazarian, LN ;
Gardiner, GA ;
Levin, DC ;
Fishman, EK .
RADIOLOGY, 1999, 211 (02) :337-343
[17]   Three-dimensional helical CT of the tracheobronchial tree: Evaluation of imaging protocols and assessment of suspected stenoses with bronchoscopic correlation [J].
Kauczor, HU ;
Wolcke, B ;
Fischer, B ;
Mildenberger, P ;
Lorenz, J ;
Thelen, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :419-424
[18]   Thoracic aortic aneurysm and aortic dissection: New endoscopic mode for three-dimensional CT display of aorta [J].
Kimura, F ;
Shen, Y ;
Date, S ;
Azemoto, S ;
Mochizuki, T .
RADIOLOGY, 1996, 198 (02) :573-578
[19]   PLEURAL INVASION BY PERIPHERAL BRONCHOGENIC-CARCINOMA - ASSESSMENT WITH 3-DIMENSIONAL HELICAL CT [J].
KURIYAMA, K ;
TATEISHI, R ;
KUMATANI, T ;
KODAMA, K ;
DOI, O ;
HOSOMI, N ;
SAWAI, Y ;
INOUE, E ;
KADOTA, T ;
NARUMI, Y ;
FUJITA, M ;
KURODA, C .
RADIOLOGY, 1994, 191 (02) :365-369
[20]   Skeletal 3-D CT: Advantages of volume rendering over surface rendering [J].
Kuszyk, BS ;
Heath, DG ;
Bliss, DF ;
Fishman, EK .
SKELETAL RADIOLOGY, 1996, 25 (03) :207-214