Forces and moments in six-DOF at the human knee joint: Mathematical description for control

被引:19
作者
Fujie, H
Livesay, GA
Fujita, M
Woo, SLY
机构
[1] KITASATO UNIV, SCH MED, DEPT BIOMED ENGN, SAGAMIHARA, KANAGAWA 228, JAPAN
[2] UNIV PITTSBURGH, SCH MED, DEPT ORTHOPAED SURG, MUSCULOSKELETAL RES CTR, PITTSBURGH, PA 15213 USA
[3] MITSUBISHI ELECTR CORP, IND ELECT & SYST LAB, AMAGASAKI, HYOGO 661, JAPAN
关键词
knee; joint coordinate system; control; force and moment; Jacobian;
D O I
10.1016/S0021-9290(96)80009-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A mathematical description of six-degree of freedom (6-DOF) forces and moments with respect to a commonly utilized knee joint coordinate system was performed using a [6 x 6] Jacobian matrix developed in this study. The presented Jacobian allows the proper transformation of the forces and moments measured at a sensor coordinate system (attached to the tibia in this case) into the joint coordinate system and is dependent on the kinematics of the joint itself. Experimental application of the developed mathematics to A-P drawer tests of the intact knee confirmed that it is possible to determine the forces and moments applied to a human knee within the joint coordinate system during joint loading. More importantly, the inverse Jacobian was also determined for implementation in the force-moment control of the joint during testing using a robotic testing system. This approach is demonstrated for the joint coordinate system for the human knee in the current study, although it may be more generally applied to allow determination and control of forces and moments within any description of motions, and for any additional joints in the human body. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:1577 / 1585
页数:9
相关论文
共 23 条
[1]   IMPLEMENTATION OF A 5-DEGREE OF FREEDOM AUTOMATED-SYSTEM TO DETERMINE KNEE FLEXIBILITY INVITRO [J].
BERNS, GS ;
HULL, ML ;
PATTERSON, HA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (04) :392-400
[2]   HELICAL AXES OF PASSIVE KNEE-JOINT MOTIONS [J].
BLANKEVOORT, L ;
HUISKES, R ;
DELANGE, A .
JOURNAL OF BIOMECHANICS, 1990, 23 (12) :1219-1229
[3]   THE ENVELOPE OF PASSIVE KNEE-JOINT MOTION [J].
BLANKEVOORT, L ;
HUISKES, R ;
DELANGE, A .
JOURNAL OF BIOMECHANICS, 1988, 21 (09) :705-+
[4]  
CHAO EYS, 1986, FRONTIERS BIOMECHANI, P225
[5]   MEASUREMENT ERRORS IN ROENTGEN-STEREOPHOTOGRAMMETRIC JOINT-MOTION ANALYSIS [J].
DELANGE, A ;
HUISKES, R ;
KAUER, JMG .
JOURNAL OF BIOMECHANICS, 1990, 23 (03) :259-269
[6]   EFFECTS OF DATA SMOOTHING ON THE RECONSTRUCTION OF HELICAL AXIS PARAMETERS IN HUMAN JOINT KINEMATICS [J].
DELANGE, A ;
HUISKES, R ;
KAUER, JMG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02) :107-113
[7]  
*FAR MED TECHN INC, 1986, GEN INSTR MAN
[8]   THE USE OF ROBOTICS TECHNOLOGY TO STUDY HUMAN JOINT KINEMATICS - A NEW METHODOLOGY [J].
FUJIE, H ;
MABUCHI, K ;
WOO, SLY ;
LIVESAY, GA ;
ARAI, S ;
TSUKAMOTO, Y .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (03) :211-217
[9]  
FUJITA M, 1987, IEEE INT WORKSH ROB, P45
[10]   AN INVITRO BIOMECHANICAL EVALUATION OF ANTERIOR-POSTERIOR MOTION OF THE KNEE - TIBIAL DISPLACEMENT, ROTATION, AND TORQUE [J].
FUKUBAYASHI, T ;
TORZILLI, PA ;
SHERMAN, MF ;
WARREN, RF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) :258-264