Transcatheter closure of atrial septal defect with Amplatzer® device in children aged less than 10 years old:: Immediate and late follow-up

被引:25
作者
Rossi, Raul I. [1 ]
Cardoso, Cristiano de Oliveira [1 ]
Machado, Paulo Renato [1 ]
Francois, Lisia Galant [2 ]
Horowitz, Estela Suzana K. [3 ]
Sarmento-Leite, Rogerio [1 ]
机构
[1] Inst Cardiol Rio Grande Do Sul, Dept Intervent Cardiol, Unidade Pesquisa IC FUC, BR-90620001 Porto Alegre, RS, Brazil
[2] Inst Cardiol Rio Grande Do Sul, Dept Anesthesiol, Porto Alegre, RS, Brazil
[3] Inst Cardiol Rio Grande Do Sul, Dept Pediat Cardiol, Porto Alegre, RS, Brazil
关键词
atrial septal defect; Amplatzer; transcatheter closure; Young children;
D O I
10.1002/ccd.21361
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To analyze the efficacy and follow-up results of percutaneous closure of Atrial septal defect (ASD) with the Amplatzer (R) septal occluder in children aged <10 years old. Methods: Between November 1998 and September 2005, 27 patients diagnosed with ASD were treated percutaneously with an Amplatzer septal occluder. The procedure was carried out in the cathlab, under general anesthesia and with both fluoroscopy and transesophageal echocardiography guidance. Basal physical examinations and echocardiograms were performed prior to the procedure and at 30 days, 6, and 12 months of follow-up. Survival free of symptom was estimated by Kaplan-Meier. Results: The mean age, weight, height, body mass index, and corporal surface was: 5.35 +/- 2.11 years, 23.07 +/- 9.43 kg, 110.55 +/- 17.6 cm, 16.77 +/- 2.42 kg/m(2), and 1.24 +/- 2.44 m(2). The prevalence of septal aneurysm was 3.7% and all patients presented single secundum ASD. The mean stretched diameter by fluoroscopy and transesophageal echocardiography were 17.18 +/- 6.75 mm and 16.77 +/- 5.99 mm, and the prostheses sizes were 18.83 +/- 6.98 mm, ranging from 10 to 30 mm. The systolic and diastolic pulmonary pressures were 25.26 +/- 5.97 mm Hg and 13.38 +/- 3.40 mm Hg, respectively. The procedure time was 82.92 +/- 29.14 min and the hospital stay was 2.20 +/- 0.26 days. Clinical and echocardiography follow-ups were performed within 11.59 +/- 4.42 months and all devices were in the correct position with no residual shunt. Right ventricular diameter decreased from 19.38 +/- 5.23mm to 11.38 +/- 11.92 (P < 0.001). No major complications or deaths occurred; two patients had a hematoma at the vascular access. Conclusion: Secundum atrial septal defect closure can be safely and successfully performed with the Amplatzer septal occluder in children younger than 10 years old. (C) 2008 Wiley-Liss,inc.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 46 条
[1]   Transcatheter closure of secundum atrial septal defects [J].
Amin, Zahid .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (05) :778-787
[2]   Incidence of thrombus formation on the CardioSEAL and the Amplatzer interatrial closure devices [J].
Anzai, H ;
Child, J ;
Natterson, B ;
Krivokapich, J ;
Fishbein, MC ;
Chan, VK ;
Tobis, JM .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04) :426-431
[3]   Surgical treatment for secundum atrial septal defects in patients &gt;40 years old -: A randomized clinical trial [J].
Attie, F ;
Rosas, M ;
Granados, N ;
Zabal, C ;
Buendía, A ;
Calderón, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (07) :2035-2042
[4]  
Bialkowski J, 2004, TEX HEART I J, V31, P220
[5]  
BRAGA SL, 2004, AR QBRAS CARDIOL, V83
[6]  
BRAUNWALD E, 2001, HEART DIS, P2297
[7]   Transcatheter closure of atrial septal defect in young children - Results and follow-up [J].
Butera, G ;
De Rosa, G ;
Chessa, M ;
Rosti, L ;
Negura, DG ;
Luciane, P ;
Giamberti, A ;
Bossone, E ;
Carminati, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (02) :241-245
[8]   Immediate and six-month results of the profile of the amplatzer septal occluder as assessed by transesophageal echocardiography [J].
Cao, QL ;
Du, ZD ;
Joseph, A ;
Koenig, P ;
Heitschmidt, M ;
Rhodes, J ;
Hijazi, ZM .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (07) :754-759
[9]   Effectiveness of the Amplatzer™ device for transcatheter closure of an ostium secundum atrial septal defect [J].
Cardoso, Cristiano Oliveira ;
Rossi Filho, Raul Ivo ;
Machado, Paulo Renato ;
Galant Francois, Lisia M. ;
Horowitz, Estela S. K. ;
Sarmento-Leite, Rogerio .
ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (04) :384-389
[10]   Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience [J].
Chan, KC ;
Godman, MJ ;
Walsh, K ;
Wilson, N ;
Redington, A ;
Gibbs, JL .
HEART, 1999, 82 (03) :300-306