Non-invasive Estimation of Cardiac Output in Mechanically Ventilated Patients: A Prolonged Expiration Method

被引:4
|
作者
Cecchini, Stefano [1 ]
Schena, Emiliano [1 ]
Notaro, Maria [2 ]
Carassiti, Massimiliano [2 ]
Silvestri, Sergio [1 ]
机构
[1] Univ Campus Biomed Roma, Ctr Integrated Res, Unit Measurements & Biomed Instrumentat, I-00128 Rome, Italy
[2] Univ Campus Biomed Roma, Ctr Integrated Res, Unit Anaesthesia & Intens Care, I-00128 Rome, Italy
关键词
Cardiac output; Fick method; Mechanical ventilation; PULMONARY BLOOD-FLOW; SINGLE-BREATH METHOD; THERMODILUTION; EXERCISE; ARTERIAL;
D O I
10.1007/s10439-012-0534-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A non-invasive method for the estimation of cardiac output in mechanically ventilated patients is described. The method is based on prolonged expiration, and relies on measurement of gas concentrations and flow rate. A pneumatic system, with an ad hoc designed orifice resistance, has been made and experimentally characterized to adapt the breathing circuit to this application. Cardiac output is calculated using two algorithms and the results are compared with the ones obtained by thermodilution. To this purpose, we prospectively enrolled twenty mechanically ventilated patients, who had undergone cardiac surgery, and both algorithms show good correlation with thermodilution (R > 0.8). The application of the first algorithm gave mean cardiac output values slightly lower than those obtained by thermodilution (-6%), while the application of the second algorithm gave higher values (+30%). Difference standard deviations between paired measurements is 0.72 L min(-1) for the first algorithm and 1.07 L min(-1) for the second one. Standard deviation obtained by the application of the first algorithm is slightly lower than those relative to other minimally invasive techniques. Through prolonged expiration, and standardization and automation of the procedure on mechanically ventilated patients, the proposed system allows to obtain a non-invasive estimation of cardiac output.
引用
收藏
页码:1777 / 1789
页数:13
相关论文
共 50 条
  • [41] Non-invasive cardiac output monitoring device “ICON” in trauma patients: a feasibility study
    Matthias Kuster
    Tobias Haltmeier
    Aristomenis Exadaktylos
    Beat Schnüriger
    European Journal of Trauma and Emergency Surgery, 2019, 45 : 1069 - 1076
  • [42] Non-invasive measurement of cardiac output during coronary artery bypass grafting
    Cohen, AJ
    Arnaudov, D
    Zabeeda, D
    Schultheis, L
    Lashinger, J
    Schachner, A
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 14 (01) : 64 - 69
  • [43] Electrical cardiometry for non-invasive cardiac output monitoring: a method comparison study in patients after coronary artery bypass graft surgery
    Greiwe, Gillis
    Saad, Rami
    Hapfelmeier, Alexander
    Neumann, Niklas
    Tariparast, Pischtaz
    Saugel, Bernd
    Flick, Moritz
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, : 371 - 376
  • [44] The predictive value of non-invasive cardiac output at rest in discharged heart failure patients
    Feola, Mauro
    Testa, Marzia
    Leto, Laura
    Rosso, Gian Luca
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 188 : 50 - 51
  • [45] Non-invasive cardiac output monitoring device "ICON" in trauma patients: a feasibility study
    Kuster, Matthias
    Haltmeier, Tobias
    Exadaktylos, Aristomenis
    Schnueriger, Beat
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2019, 45 (06) : 1069 - 1076
  • [46] Evaluation of a noninvasive cardiac output monitor in mechanically ventilated children
    Botte, Astrid
    Leclerc, Francis
    Riou, Yvon
    Sadik, Ahmed
    Neve, Veronique
    Rakza, Tameur
    Richard, Adelaide
    PEDIATRIC CRITICAL CARE MEDICINE, 2006, 7 (03) : 231 - 236
  • [47] Performance of different add-on devices in dual limb non-invasive mechanically ventilated circuit
    Rashad, Amal E.
    Mohammad, Mohammad F.
    Eckes, Myriam
    Poree, Thierry
    Sarhan, Rania M.
    Madney, Yasmin M.
    Abdelrahim, Mohamed EA.
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2021, 66
  • [48] Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients.
    Dong L.
    Wang J.A.
    Jiang C.Y.
    Journal of Zhejiang University SCIENCE B, 2005, 6 (12): : 1157 - 1162
  • [49] Influence of systemic vascular resistance on cardiac output measured by new non-invasive cardiac output monitor
    K Yamashita
    T Yamatabe
    H Abe
    M Yokoyama
    Critical Care, 14 (Suppl 1):
  • [50] Non-Invasive Cardiac Output Monitoring in Cardiogenic Shock: The NICOM Study
    Rali, Aniket S.
    Buechler, Tyler
    Van Gotten, Bridget
    Waters, Andrew
    Shah, Zubair
    Haglund, Nicholas
    Sauer, Andrew
    JOURNAL OF CARDIAC FAILURE, 2020, 26 (02) : 160 - 165