Non-invasive Estimation of Cardiac Output in Mechanically Ventilated Patients: A Prolonged Expiration Method

被引:5
作者
Cecchini, Stefano [1 ]
Schena, Emiliano [1 ]
Notaro, Maria [2 ]
Carassiti, Massimiliano [2 ]
Silvestri, Sergio [1 ]
机构
[1] Univ Campus Biomed Roma, Ctr Integrated Res, Unit Measurements & Biomed Instrumentat, I-00128 Rome, Italy
[2] Univ Campus Biomed Roma, Ctr Integrated Res, Unit Anaesthesia & Intens Care, I-00128 Rome, Italy
关键词
Cardiac output; Fick method; Mechanical ventilation; PULMONARY BLOOD-FLOW; SINGLE-BREATH METHOD; THERMODILUTION; EXERCISE; ARTERIAL;
D O I
10.1007/s10439-012-0534-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A non-invasive method for the estimation of cardiac output in mechanically ventilated patients is described. The method is based on prolonged expiration, and relies on measurement of gas concentrations and flow rate. A pneumatic system, with an ad hoc designed orifice resistance, has been made and experimentally characterized to adapt the breathing circuit to this application. Cardiac output is calculated using two algorithms and the results are compared with the ones obtained by thermodilution. To this purpose, we prospectively enrolled twenty mechanically ventilated patients, who had undergone cardiac surgery, and both algorithms show good correlation with thermodilution (R > 0.8). The application of the first algorithm gave mean cardiac output values slightly lower than those obtained by thermodilution (-6%), while the application of the second algorithm gave higher values (+30%). Difference standard deviations between paired measurements is 0.72 L min(-1) for the first algorithm and 1.07 L min(-1) for the second one. Standard deviation obtained by the application of the first algorithm is slightly lower than those relative to other minimally invasive techniques. Through prolonged expiration, and standardization and automation of the procedure on mechanically ventilated patients, the proposed system allows to obtain a non-invasive estimation of cardiac output.
引用
收藏
页码:1777 / 1789
页数:13
相关论文
共 29 条
[1]   Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model [J].
Bajorat, J ;
Hofmockel, R ;
Vagts, DA ;
Janda, M ;
Pohl, B ;
Beck, C ;
Noeldge-Schomburg, G .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (01) :23-30
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Measurement of cardiac output before and after cardiopulmonary bypass:: Comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing [J].
Botero, M ;
Kirby, D ;
Lobato, EB ;
Staples, ED ;
Gravenstein, N .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2004, 18 (05) :563-572
[4]  
Cecchini S, 2011, IEEE ENG MED BIO, P1245, DOI 10.1109/IEMBS.2011.6090293
[5]  
Cecchini S., 2011, MEMEA 2011 IEEE INT, P143
[6]   EVALUATION OF A METHOD FOR ESTIMATING CARDIAC-OUTPUT FROM A SINGLE BREATH IN HUMANS [J].
CHEN, H ;
SILVERTON, NP ;
HAINSWORTH, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (04) :1034-1038
[7]  
CHRISTENSEN P, 1986, CLIN PHYSIOL, V6, P221, DOI 10.1111/j.1475-097X.1986.tb00621.x
[8]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[9]   CARDIAC-OUTPUT MEASUREMENTS - A REVIEW OF CURRENT TECHNIQUES AND RESEARCH [J].
EHLERS, KC ;
MYLREA, KC ;
WATERSON, CK ;
CALKINS, JM .
ANNALS OF BIOMEDICAL ENGINEERING, 1986, 14 (03) :219-239
[10]  
F A., 1870, Verh Phys Med Ges Wurzburg, V2, P16