摘要
A comprehensive evaluation and a thorough discussion of the fields of possible applications of the Direct-EI interface are described in this review. Direct-EI allows the direct introduction of the effluent from a capillary HPLC column into the electron ionization (EI) ion source of a mass spectrometer Thanks to the reduced liquid intake and an in-source nebulizer the interfacing process occurs smoothly and entirely into the ion source. No intermediate interfacing mechanisms of any sort are interposed between the column and the mass spectrometer, thus circumventing any undesired sample loss and minimizing the effort for instrument modification. Theoretically, any GC-MS system can be converted into an LC-MS for EI amenable compounds. Several parameters, crucial for a successful integration of liquid chromatography and mass spectrometry, have been considered in the evaluation of the functioning of such an interface: limit of detection, linearity of response, reproducibility, and chromatographic compatibility. Different mobile phases, also containing non-volatile buffers, were taken into account, demonstrating an outstanding separation flexibility. The entire set of experiments was carried out at different flow rates and temperatures of the ion source. The interface behavior was also tested in real world applications, with mixtures of pesticides, hormones, nitro-PAH, and endocrine-disrupting compounds, allowing picogram level detection and the possibility to record library-matchable, readily interpretable electron ionization mass spectra, for prompt compound characterization and confirmation. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:978 / 989
页数:12
相关论文
共 26 条
[1]   Liquid chromatography mass spectrometry with supersonic molecular beams [J].
Amirav, A ;
Granot, O .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (06) :587-591
[2]   The critical evaluation of a comprehensive mass spectral library [J].
Ausloos, P ;
Clifton, CL ;
Lias, SG ;
Mikaya, AI ;
Stein, SE ;
Tchekhovskoi, DV ;
Sparkman, OD ;
Zaikin, V ;
Zhu, D .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (04) :287-299
[3]   Liquid chromatographic-mass spectrometric determination of phenolic compounds using a capillary-scale particle beam interface [J].
Cappiello, A ;
Famiglini, G ;
Mangani, F ;
Careri, M ;
Lombardi, P ;
Mucchino, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (02) :515-527
[4]  
Cappiello A, 1996, MASS SPECTROM REV, V15, P283, DOI 10.1002/(SICI)1098-2787(1996)15:5<283::AID-MAS1>3.0.CO
[5]  
2-E
[6]   An efficient liquid chromatography - Mass spectrometry interface for the generation of electron ionization spectra [J].
Cappiello, A ;
Balogh, M ;
Famiglini, G ;
Mangani, F ;
Palma, P .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3841-3846
[7]   NEW APPROACH FOR THE ANALYSIS OF ACIDIC PESTICIDES IN WATER BY LC/MS WITH A PARTICLE-BEAM INTERFACE [J].
CAPPIELLO, A ;
FAMIGLINI, G ;
PALMA, P ;
BERLONI, A ;
BRUNER, F .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (09) :2295-2300
[9]   MICRO FLOW-RATE PARTICLE BEAM INTERFACE FOR CAPILLARY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CAPPIELLO, A ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1281-1287
[10]   Electron ionization for LC/MS [J].
Cappiello, A ;
Famiglini, G ;
Palma, P .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :496A-503A