Digital radiography of the chest in pediatric patients

被引:7
作者
Puig, S [1 ]
机构
[1] Univ Vienna, Klin Radiodiagnost, A-1090 Vienna, Austria
来源
RADIOLOGE | 2003年 / 43卷 / 12期
关键词
chest radiography; digital radiography; children;
D O I
10.1007/s00117-003-0983-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The hopes placed in digital radiography have been fulfilled only partly in pediatric radiology. Specifically, the option of gaining reduced radiation exposure in combination with a similar or even improved image quality was hard to realize. The only portable digital system available fora long time were storage phosphors which were disadvantaged by an extremely limited close-quantum-efficiency (DQE) in comparison to digital flat panel detectors. New developments and the introduction of the dual-reading system led to image qualities comparable to film-screen-systems with high resolution and achievable without dose increase, sometimes even with dose reduction. A study using an animal model suggests that these systems can even be used in preterm infants with very low birth weights. A new portable flat panel detector by Canon may improve digital chest radiography in pediatric patients.
引用
收藏
页码:1045 / 1050
页数:6
相关论文
共 26 条
[1]   Novel computed radiography system with improved image quality by detection of emissions from both sides of an Imaging Plate [J].
Arakawa, S ;
Itoh, W ;
Kohda, K ;
Suzuki, T .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :572-581
[2]   Radiation dose quantities and risk in neonates in a special care baby unit [J].
Armpilia, CI ;
Fife, IAJ ;
Croasdale, PL .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (895) :590-595
[3]  
Busch HP, 1999, RADIOLOGE, V39, P710, DOI 10.1007/s001170050569
[4]  
Doody MM, 2000, SPINE, V25, P2052
[5]   New computed radiography technologies in digital radiography [J].
Fasbender, R ;
Schaetzing, R .
RADIOLOGE, 2003, 43 (05) :367-373
[6]   Performance evaluation of a "dual-side read" dedicated mammography computed radiography system [J].
Fetterly, KA ;
Schueler, BA .
MEDICAL PHYSICS, 2003, 30 (07) :1843-1854
[7]   Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography [J].
Floyd, CE ;
Warp, RJ ;
Dobbins, JT ;
Chotas, HG ;
Baydush, AH ;
Vargas-Voracek, R ;
Ravin, CE .
RADIOLOGY, 2001, 218 (03) :683-688
[8]   Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications [J].
Granfors, PR ;
Aufrichtig, R .
MEDICAL PHYSICS, 2000, 27 (06) :1324-1331
[9]   IMAGING PERFORMANCE OF A DIGITAL STORAGE PHOSPHOR SYSTEM [J].
HILLEN, W ;
SCHIEBEL, U ;
ZAENGEL, T .
MEDICAL PHYSICS, 1987, 14 (05) :744-751
[10]   Mottle on computed radiographs of the chest in pediatric patients [J].
Huda, W ;
Slone, RM ;
Belden, CJ ;
Williams, JL ;
Cumming, WA ;
Palmer, CK .
RADIOLOGY, 1996, 199 (01) :249-252