Effect of directional switching frequency on toluene degradation in a vapor-phase bioreactor

被引:21
作者
Song, J [1 ]
Kinney, KA [1 ]
机构
[1] Univ Texas, Dept Civil Engn, Austin, TX 78712 USA
关键词
D O I
10.1007/s002530100601
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A potential method to improve biomass distribution and the stability of vapor-phase bioreactors is to operate them in a directionally switching mode such that the contaminant air stream direction is periodically reversed through the reactor. In this study, the effect of switching frequency (SF) on bioreactor performance and biodegradation activity was investigated at 1-, 3- and 7-day SFs using toluene as a model compound. Rapid losses of biodegradation capacity and serious bioreactor instability were observed in the bioreactor operated at a 1-day SF. It is hypothesized that the frequent dynamic loading conditions at the I-day SF hindered biofilm development and ultimately bioreactor stability. In contrast, bioreactors operated at the 3- and 7-day SFs achieved overall removal efficiencies of greater than 99% for 72 and 59 days of operation, respectively. Following each air-stream reversal, the bioreactor operated at the 7-day SF required 48 h to fully restore biodegradation capacity in the inlet bioreactor section. The 1-day SF bioreactor required no such reacclimation period. The toluene-degrading activity in the inlet section of the 7-day SF bioreactor dropped by 71% during the 7-day cycle, whereas it decreased by only 11% in the inlet of the 3-day SF bioreactor. These declines suggest that continuous or near-continuous exposure to toluene can inhibit microbial activity. Of the three SFs examined, the 3-day SF yielded the most efficient bioreactor performance by balancing reacclimation requirements with biodegradation activity losses.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 16 条
  • [1] Influence of water content on degradation rates for ethanol in biofiltration
    Auria, R
    Aycaguer, AC
    Devinny, JS
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1998, 48 (01): : 65 - 70
  • [2] Cox HHJ, 1999, BIOTECHNOL BIOENG, V62, P216
  • [3] Development and validation of a simple protocol to rapidly determine the performance of biofilters for VOC treatment
    Deshusses, MA
    Johnson, CT
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (03) : 461 - 467
  • [4] MATHEMATICAL-ANALYSIS OF CATABOLIC FUNCTION LOSS IN A POPULATION OF PSEUDOMONAS-PUTIDA MT-2 DURING NON-LIMITED GROWTH ON BENZOATE
    DUETZ, WA
    WINSON, MK
    VANANDEL, JG
    WILLIAMS, PA
    [J]. JOURNAL OF GENERAL MICROBIOLOGY, 1991, 137 : 1363 - 1368
  • [5] Laurenzis A, 1998, BIOTECHNOL BIOENG, V57, P497
  • [6] CATABOLITE-MEDIATED MUTATIONS IN ALTERNATE TOLUENE DEGRADATIVE PATHWAYS IN PSEUDOMONAS-PUTIDA
    LEDDY, MB
    PHIPPS, DW
    RIDGWAY, HF
    [J]. JOURNAL OF BACTERIOLOGY, 1995, 177 (16) : 4713 - 4720
  • [7] Effect of periods of non-use on biofilter performance
    Martin, FJ
    Loehr, RC
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (06): : 539 - 546
  • [8] Mirpuri R, 1997, BIOTECHNOL BIOENG, V53, P535
  • [9] Morgenroth E, 1996, J AIR WASTE MANAGE, V46, P300, DOI 10.1080/10473289.1996.10467464
  • [10] IDENTIFICATION AND CATABOLIC ACTIVITY OF WELL-DERIVED GASOLINE-DEGRADING BACTERIA FROM A CONTAMINATED AQUIFER
    RIDGWAY, HF
    SAFARIK, J
    PHIPPS, D
    CARL, P
    CLARK, D
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1990, 56 (11) : 3565 - 3575