Diagnostic Accuracy of Point-of-Care Tests Measuring Glycosylated Haemoglobin (HbA1c) for Glycemic Control: A Field Study in India

被引:1
作者
Khadanga, Sagar [1 ]
Singh, Gyanendra [2 ]
Pakhare, Abhijit P. [2 ]
Joshi, Rajnish [1 ]
机构
[1] All India Inst Med Sci, Internal Med, Bhopal, India
[2] All India Inst Med Sci, Community & Family Med, Bhopal, India
关键词
hba1c; diagnostic accuracy; point of care; diabetes; glycaemic control; COMPLICATIONS; PREVALENCE;
D O I
10.7759/cureus.17920
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study was performed to estimate diagnostic accuracy of the two commercially available point-of-care tests to identify poor glycemic control defined by HbA1c levels, with high-performance liquid chromatography (HPLC) as a reference. Settings The study was carried at two locations, general medical outpatient department of a teaching medical college in Bhopal (urban), and a primary health care centre in a rural area in the state of Madhya Pradesh, India. Participants All individuals with diabetes mellitus who presented to the health care facility for assessment of glycemic control. We compared HbA1c estimated from two index tests (Hemocue Hb 501, Sweden; SD Biosensor, South Korea) from capillary blood samples with HPLC performed from venous blood, as a reference standard. Primary and secondary outcome measures Diagnostic properties of index tests such as sensitivity, specificity, positive and negative predictive value and diagnostic accuracy for identifying poor glycemic control were primary outcome measures. Lin's concordance correlation coefficient (CCC) was secondary outcome measure. Results Out of 114 patients, all received reference standard -103 patients received Hemocue A1C test and 110 patients received SD Biosensor test. Overall both the index tests had similar diagnostic accuracy estimates. The area under the Receiver Operating Curve for SDA1c device was 0.935 (95% CI 0.886-0.983), and for Hemocue device was 0.938 (95% CI 0.893-0.984). The Hemocue device HbA1c value of above 7.0 (positive) correctly predicted poor glycemic control 92% times (81.58% for SD device). There were 4 vs. 11 device failures and 14 vs. 12 failures with SD and Hemocue, respectively. Ambient air temperatures were no different for the device test failures. Conclusions Commercially available point-of-care tests evaluated in this study are comparable and an acceptable alternative to HPLC-based measurements for the assessment of glycemic control. Tests and device failure rates of both the index tests are similar.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Level of agreement of point-of-care and laboratory HbA1c measurements in the preoperative outpatient clinic in non-diabetic patients who are overweight or obese
    van Raalten, Floris
    Hiemstra, Yasmine L.
    Keulen, Noor
    van Duivenvoorde, Yoni
    Stoecklein, Katrin
    Verhagen, Evert A.
    Boer, Christa
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (06) : 1139 - 1144
  • [32] SCREENING FOR TYPE 2 DIABETES MELLITUS AND PREDIABETES USING POINT-OF-CARE TESTING FOR HBA1C AMONG THAI DENTAL PATIENTS
    Tantipoj, Chanita
    Sakoolnamarka, Serena Siraratna
    Supa-amornkul, Sirirak
    Lohsoonthorn, Vitool
    Deerochanawong, Chaicharn
    Khovidhunkit, Siribangon Piboonniyom
    Hiransuthikul, Narin
    [J]. SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2017, 48 (02) : 455 - 465
  • [33] Performance of point-of-care HbA1c test devices: implications for use in clinical practice - a systematic review and meta-analysis
    Hirst, Jennifer A.
    McLellan, Julie H.
    Price, Christopher P.
    English, Emma
    Feakins, Benjamin G.
    Stevens, Richard J.
    Farmer, Andrew J.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (02) : 167 - 180
  • [34] Above 40% of Polish children and young adults with type 1 diabetes achieve international HbA1c target - results of a nationwide cross-sectional evaluation of glycemic control: The PolPeDiab HbA1c study
    Szadkowska, Agnieszka
    Baranowska-Jazwiecka, Anna
    Michalak, Arkadiusz
    Jarosz-Chobot, Przemyslawa
    Mysliwiec, Malgorzata
    Glowinska-Olszewska, Barbara
    Szypowska, Agnieszka
    Nazim, Joanna
    Mazur, Artur
    Szalecki, Mieczyslaw
    Skowronska, Bogda
    Kucharska-Zubkiewicz, Agnieszka
    Ben-Skowronek, Iwona
    Walczak, Mieczyslaw
    Klupa, Tomasz
    Wolnik, Bogumil
    Zozulinska-Ziolkiewicz, Dorota
    Mlynarski, Wojciech
    [J]. PEDIATRIC DIABETES, 2021, 22 (07) : 1003 - 1013
  • [35] Diagnostic Accuracy of Point-of-care Tests Used to Detect Arterial Disease in Diabetes TEsting for Arterial Disease in Diabetes (TrEAD) Study
    Normahani, Pasha
    Poushpas, Sepideh
    Alaa, Mays
    Bravis, Vassiliki
    Sounderajah, Viknesh
    Aslam, Mohammed
    Jaffer, Usman
    [J]. ANNALS OF SURGERY, 2022, 276 (05) : E605 - E612
  • [36] Can the Afinion HbA1c Point-of-Care instrument be an alternative method for the Tosoh G8 in the case of Hb-Tacoma?
    Lenters-Westra, Erna
    Strunk, Annuska
    Campbell, Paul
    Slingerland, Robbert J.
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2017, 77 (01) : 2 - 7
  • [37] Cross-sectional comparison of point-of-care with laboratory HbA1c in detecting diabetes in real-world remote Aboriginal settings
    Marley, Julia V.
    Oh, May S.
    Hadgraft, Nyssa
    Singleton, Sally
    Isaacs, Kim
    Atkinson, David
    [J]. BMJ OPEN, 2015, 5 (03):
  • [38] Number of HbA1c tests unrelated to quality of diabetes control: An electronic medical record data linkage study
    Glazier, Richard H.
    Harris, Stewart B.
    Tompkins, Jordan W.
    Wilton, Andrew S.
    Chevendra, Vijaya
    Stewart, Moira A.
    Thind, Amardeep
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 93 (01) : E37 - E40
  • [39] Comparison of Glycosylated Hemoglobin (HbA1c) Levels in 2009 and 2012 among Diabetic Patients at a Primary Care Clinic: A Retrospective Cohort Study
    Al Turki, Yousef Abdullah
    [J]. KUWAIT MEDICAL JOURNAL, 2014, 46 (04): : 319 - 322
  • [40] Self-awareness of HbA1c and its association with glycemic control among patients with type 2 diabetes A multicenter study
    Almutairi, Joud S.
    Almigbal, Turky H.
    Alruhaim, Hiba Y.
    Mujammami, Muhammad H.
    AlMogbel, Turki A.
    Alshahrani, Abdullah M.
    Al Zahrani, Abdullah M.
    Batais, Mohammed A.
    Shaik, Shaffi A.
    [J]. SAUDI MEDICAL JOURNAL, 2022, 43 (03) : 291 - 300