Diagnostic Accuracy of Point-of-Care Tests Measuring Glycosylated Haemoglobin (HbA1c) for Glycemic Control: A Field Study in India

被引:1
作者
Khadanga, Sagar [1 ]
Singh, Gyanendra [2 ]
Pakhare, Abhijit P. [2 ]
Joshi, Rajnish [1 ]
机构
[1] All India Inst Med Sci, Internal Med, Bhopal, India
[2] All India Inst Med Sci, Community & Family Med, Bhopal, India
关键词
hba1c; diagnostic accuracy; point of care; diabetes; glycaemic control; COMPLICATIONS; PREVALENCE;
D O I
10.7759/cureus.17920
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study was performed to estimate diagnostic accuracy of the two commercially available point-of-care tests to identify poor glycemic control defined by HbA1c levels, with high-performance liquid chromatography (HPLC) as a reference. Settings The study was carried at two locations, general medical outpatient department of a teaching medical college in Bhopal (urban), and a primary health care centre in a rural area in the state of Madhya Pradesh, India. Participants All individuals with diabetes mellitus who presented to the health care facility for assessment of glycemic control. We compared HbA1c estimated from two index tests (Hemocue Hb 501, Sweden; SD Biosensor, South Korea) from capillary blood samples with HPLC performed from venous blood, as a reference standard. Primary and secondary outcome measures Diagnostic properties of index tests such as sensitivity, specificity, positive and negative predictive value and diagnostic accuracy for identifying poor glycemic control were primary outcome measures. Lin's concordance correlation coefficient (CCC) was secondary outcome measure. Results Out of 114 patients, all received reference standard -103 patients received Hemocue A1C test and 110 patients received SD Biosensor test. Overall both the index tests had similar diagnostic accuracy estimates. The area under the Receiver Operating Curve for SDA1c device was 0.935 (95% CI 0.886-0.983), and for Hemocue device was 0.938 (95% CI 0.893-0.984). The Hemocue device HbA1c value of above 7.0 (positive) correctly predicted poor glycemic control 92% times (81.58% for SD device). There were 4 vs. 11 device failures and 14 vs. 12 failures with SD and Hemocue, respectively. Ambient air temperatures were no different for the device test failures. Conclusions Commercially available point-of-care tests evaluated in this study are comparable and an acceptable alternative to HPLC-based measurements for the assessment of glycemic control. Tests and device failure rates of both the index tests are similar.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Agreement between the "point of care' tests for microalbuminuria and HbA1c performed in mexican family medicine units and the results of standard laboratory tests
    Valdez-Gonzalez, Leticia A.
    Mendez-Padron, Araceli
    Gomez-Diaz, Rita A.
    Valladares-Salgado, Adan
    Sanchez-Becerra, Martha Catalina
    Mondragon-Gonzalez, Rafael
    Hernandez-Rubi, Jaime
    Gonzalez-Hermosillo, Arturo
    Cruz, Miguel
    Borja, Victor
    Wacher, Niels H.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2018, 78 (1-2) : 87 - 93
  • [22] Derivation validation of glycosylated haemoglobin (HbA1c) cut-off value as a diagnostic test for type 2 diabetes in south Indian population
    Mohan, Alladi
    Reddy, S. Aparna
    Sachan, Alok
    Sarma, K. V. S.
    Kumar, D. Prabath
    Panchagnula, Mahesh V.
    Rao, P. V. L. N. Srinivasa
    Kumar, B. Siddhartha
    Krishnaprasanthi, P.
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2016, 144 : 220 - 228
  • [23] Comparison of longitudinal point-of-care and high-performance liquid chromatography HbA1c measurements in a multi-centre trial
    Alleyn, C. R.
    Laffel, L. M. B.
    Volkening, L. K.
    Anderson, B. J.
    Nansel, T. R.
    Wysocki, T.
    Weissberg-Benchell, J.
    DIABETIC MEDICINE, 2011, 28 (12) : 1525 - 1529
  • [24] The use of glycated haemoglobin (HbA1c) in determining glycemic control (and relevance of BMI) in diabetic patients in Ahmadu Bello University Teaching Hospital Zaria, Nigeria
    Mustafa, Ibrahim Oladayo
    Tanko, Yusuf
    Yusuf, Rasheed
    Musa, Sunday Abraham
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2019, 13 (05) : 2967 - 2972
  • [25] Point-of-care capillary HbA1c measurement in the emergency department: a useful tool to detect unrecognized and uncontrolled diabetes
    Gomez-Peralta F.
    Abreu C.
    Andreu-Urioste L.
    Antolí A.C.
    Rico-Fontsaré C.
    Martín-Fernández D.
    Resina-Rufes R.
    Pérez-García J.J.
    Negrete-Muñoz Á.
    Muñoz-Álvarez D.
    Umpierrez G.E.
    International Journal of Emergency Medicine, 2016, 9 (1) : 1 - 6
  • [26] Point of care HbA1c level for diabetes mellitus management and its accuracy among tuberculosis patients: a study in four countries
    Huangfu, P.
    Laurence, Y. V.
    Alisjahbana, B.
    Ugarte-Gil, C.
    Riza, A-L.
    Walzl, G.
    Ruslami, R.
    Moore, D. A. J.
    Ioana, M.
    McAllister, S.
    Ronacher, K.
    Koesoemadinata, R. C.
    Grint, D.
    Kerry, S.
    Coronel, J.
    Malherbe, S. T.
    Griffiths, U.
    Dockrell, H. M.
    Hill, P. C.
    van Crevel, R.
    Pearson, F.
    Critchley, J. A.
    Dockrell, H. M.
    Cliff, J. M.
    Eckold, C.
    Moore, D. A.
    Griffiths, U. K.
    Critchley, J. A.
    Kerry, S. R.
    Pearson, F.
    Grint, D.
    Anmontse, R.
    Netea, M. N.
    van Crevel, R.
    Ruesen, C.
    Lachmandas, E.
    Joosten, S. A.
    Ottenhoff, T. H. M.
    Vrieling, F.
    Haks, M. C.
    Kumar, V.
    Wijmenga, C.
    Kaufmann, S. H. E.
    Beigier, M.
    Golinski, R.
    Walzl, G.
    Ronacher, K.
    Malherbe, S. T.
    Kleynhans, L.
    Smith, B.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2019, 23 (03) : 283 - +
  • [27] Point-of-care Testing HbA1c screening for type 2 diabetes in urban and rural areas of China: a cost-effectiveness analysis
    Shao, Qing
    Xie, Xinglei
    Wang, Liu
    Gao, Lanyu
    Hu, Yuchen
    Zhang, Yuwei
    FRONTIERS IN PUBLIC HEALTH, 2024, 12
  • [28] Point-of-Care HbA1c Testing With the A1cNow Test Kit in General Practice Dental Clinics A Pilot Study Involving Its Accuracy and Practical Issues in Its Use
    Strauss, Shiela M.
    Pesce, Michael A.
    Juterbock, Caroline
    Kaur, Navjot
    DePaola, Joe
    Goetz, Deborah
    Wolff, Mark S.
    Malaspina, Dolores
    Danoff, Ann
    POINT OF CARE, 2014, 13 (04): : 142 - 147
  • [29] Do people with diabetes understand their clinical marker of long-term glycemic control (HbA1c levels) and does this predict diabetes self-care behaviours and HbA1c?
    Beard, Emma
    Clark, Marie
    Hurel, Steve
    Cooke, Debbie
    PATIENT EDUCATION AND COUNSELING, 2010, 80 (02) : 227 - 232
  • [30] Socioeconomic Factors Associated With Glycemic Measurement and Poor HbA1c Control in People With Type 2 Diabetes: The Global DISCOVER Study
    Gomes, Marilia B.
    Tang, Fengming
    Chen, Hungta
    Cid-Ruzafa, Javier
    Fenici, Peter
    Khunti, Kamlesh
    Rathmann, Wolfgang
    Shestakova, Marina V.
    Surmont, Filip
    Watada, Hirotaka
    Medina, Jesus
    Shimomura, Iichiro
    Saraiva, Gabriela Luporini
    Cooper, Andrew
    Nicolucci, Antonio
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13