Inelastic Second-Order Analysis for Slender GFRP-Reinforced Concrete Columns: Experimental Investigations and Theoretical Study

被引:37
作者
Abdelazim, Waseem [1 ]
Mohamed, Hamdy M. [1 ]
Benmokrane, Brahim [2 ,3 ,4 ]
机构
[1] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Civil Engn, Dept Civil Engn, 2500 Blvd Univ, Sherbrooke, PQ J1K 2R1, Canada
[3] Univ Sherbrooke, Adv Composite Mat Civil Struct, Dept Civil Engn, 2500 Blvd Univ, Sherbrooke, PQ J1K 2R1, Canada
[4] Univ Sherbrooke, Innovat FRP Reinforcement Concrete Infrastruct, Dept Civil Engn, 2500 Blvd Univ, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Columns; Design codes; First and second-order analysis; Glass fiber-reinforced polymer rebars; Instability and buckling; Lateral displacement; Short and slender columns; Slenderness ratio; Stiffness; Reinforced concrete; STABILITY ANALYSIS; FIBER; STRENGTH; DESIGN; BARS; BEHAVIOR; STEEL;
D O I
10.1061/(ASCE)CC.1943-5614.0001019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Designing reinforced concrete (RC) columns reinforced entirely with fiber-reinforced polymer (FRP) bars requires an explicit definition of the slenderness upper and lower limits for use in code provisions. To date, limited research has focused on experimentally assessing the behavior of slender FRP-reinforced concrete (FRP-RC) columns. Therefore, North American codes and guidelines lack design provisions. This study was conducted to enrich the research database with a total of 20 full-scale columns reinforced with steel or glass FRP (GFRP) bars. The columns were 305 mm in diameter and had slenderness ratios of 14, 19, 23, 26, and 33 were tested under concentric and eccentric loading. The steel-reinforced columns were tested to serve as a benchmark for their GFRP-reinforced concrete (GFRP-RC) counterparts. The interrelated effects between the slenderness ratio and the load eccentricity level were investigated with four different eccentricity-to-diameter ratios of 0%, 16%, 33%, and 66%. Test results proved the efficiency of GFRP bars as internal reinforcement for slender RC columns. The research program was then extended, developing a second-order model for slender FRP-RC columns. A good correlation was observed between the experimental results and the model developed analytically. In addition, based on the stability analysis, it was found that the available design equation for stability failure of steel-reinforced concrete (steel-RC) columns was appropriate and could also be applied to GFRP-RC. Finally, the experimental results and the analytical model indicated that a maximum slenderness limit of 18 was appropriate for short GFRP-RC columns bent in a single curve.
引用
收藏
页数:14
相关论文
共 40 条
[1]  
AASHTO, 2018, LRFD bridge design guide specifications for GFRP-reinforced concrete
[2]  
ACI (American Concrete Institute), 2019, 31919 ACI
[3]  
ACI Committee 440, 2015, ACI440.1R-15, DOI DOI 10.1061/40753(171)158
[4]   Strength and Axial Behavior of Circular Concrete Columns Reinforced with CFRP Bars and Spirals [J].
Afifi, Mohammad Z. ;
Mohamed, Hamdy M. ;
Benmokrane, Brahim .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (02)
[5]  
[Anonymous], 2014, Design of Concrete Structures. CSA Standard A23.3-14
[6]  
[Anonymous], ACI J P
[7]  
[Anonymous], ACI J P
[8]  
ASTM, 2008, D2584 ASTM
[9]  
BAZANT ZP, 1991, ACI STRUCT J, V88, P391
[10]  
Canadian Standards Association (CSA), 2012, S80612 CSA