Anterior chamber angle imaging with optical coherence tomography

被引:82
|
作者
Leung, C. K-S [1 ]
Weinreb, R. N. [2 ]
机构
[1] Chinese Univ Hong Kong, Hong Kong Eye Hosp, Dept Ophthalmol & Visual Sci, Kowloon, Hong Kong, Peoples R China
[2] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, San Diego, CA 92103 USA
关键词
anterior chamber angle imaging; optical coherence tomography; swept-source OCT; spectral-domain OCT; IN-VIVO; ULTRASOUND BIOMICROSCOPY; CLOSURE GLAUCOMA; DYNAMIC-ANALYSIS; SCLERAL SPUR; SWEPT-SOURCE; SEGMENT; PHACOEMULSIFICATION; REPRODUCIBILITY; CONFIGURATION;
D O I
10.1038/eye.2010.201
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The technology of optical coherence tomography (OCT) has evolved rapidly from time-domain to spectral-domain and swept-source OCT over the recent years. OCT has become an important tool for assessment of the anterior chamber angle and detection of angle closure. Improvement in image resolution and scan speed of OCT has facilitated a more detailed and comprehensive analysis of the anterior chamber angle. It is now possible to examine Schwalbe's line and Schlemm's canal along with the scleral spur. High-speed imaging allows evaluation of the angle in 360 degrees. With three-dimensional reconstruction, visualization of the iris profiles and the angle configurations is enhanced. This article summarizes the development and application of OCT for anterior chamber angle measurement, detection of angle closure, and investigation of the pathophysiology of primary angle closure. Eye (2011) 25, 261-267; doi:10.1038/eye.2010.201; published online 14 January 2011
引用
收藏
页码:261 / 267
页数:7
相关论文
共 50 条
  • [1] Anterior chamber angle imaging with optical coherence tomography
    C K-S Leung
    R N Weinreb
    Eye, 2011, 25 : 261 - 267
  • [2] Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: An Investigation on Variability of Angle Measurement
    Liu, Shu
    Yu, Marco
    Ye, Cong
    Lam, Dennis S. C.
    Leung, Christopher Kai-shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 8598 - 8603
  • [3] Anterior Chamber Angle Evaluation with Fourier-Domain Optical Coherence Tomography
    Bald, Matthew
    Li, Yan
    Huang, David
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [4] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    Sakata, L. M.
    Wong, T. T. L.
    Wong, H-T
    Kumar, R. S.
    Htoon, H. M.
    Aung, H. T.
    He, M.
    Aung, T.
    EYE, 2010, 24 (04) : 578 - 587
  • [5] Comparing Gonioscopy With Visante and Cirrus Optical Coherence Tomography for Anterior Chamber Angle Assessment in Glaucoma Patients
    Hu, Cindy X.
    Mantravadi, Anand
    Zangalli, Camila
    Ali, Mohsin
    Faria, Bruno M.
    Richman, Jesse
    Wizov, Sheryl S.
    Razeghinejad, M. Reza
    Moster, Marlene R.
    Katz, L. Jay
    JOURNAL OF GLAUCOMA, 2016, 25 (02) : 177 - 183
  • [6] Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark
    Cheung, Carol Y.
    Zheng, Ce
    Ho, Ching-Lin
    Tun, Tin A.
    Kumar, Rajesh S.
    El Sayyad, Fouad
    Wong, Tien Y.
    Aung, Tin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) : 955 - 959
  • [7] Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography
    Khor, Wei-Boon
    Sakata, Lisandro M.
    Friedman, David S.
    Narayanaswamy, Arun
    Lavanya, Raghavan
    Perera, Shamira A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 365 - 368
  • [8] Comparison of Different Modes in Optical Coherence Tomography and Ultrasound Biomicroscopy in Anterior Chamber Angle Assessment
    Wang, Dandan
    Pekmezci, Melike
    Basham, Ryan P.
    He, Mingguang
    Seider, Michael I.
    Lin, Shan C.
    JOURNAL OF GLAUCOMA, 2009, 18 (06) : 472 - 478
  • [9] Anterior Chamber Angle Measurements Using Schwalbe's Line With High-resolution Fourier-Domain Optical Coherence Tomography
    Qin, Bing
    Francis, Brian A.
    Li, Yan
    Tang, Maolong
    Zhang, Xinbo
    Jiang, Chunhui
    Cleary, Catherine
    Huang, David
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 684 - 688
  • [10] Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography
    Kim, Dong Y.
    Sung, Kyung R.
    Kang, Sung Y.
    Cho, Jung W.
    Lee, Kyoung S.
    Park, Seong B.
    Kim, Soon T.
    Kook, Michael S.
    ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 435 - 441