Damage detection of carbon fiber reinforced polymer composites via electrical resistance measurement

被引:198
作者
Wen, Jie [1 ]
Xia, Zhenhai [1 ]
Choy, Fred [1 ]
机构
[1] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
关键词
Carbon fiber; Electrical properties; Non-destructive testing; MATRIX COMPOSITE; FATIGUE DAMAGE; CFRP COMPOSITES; MECHANICAL DAMAGE; STRAIN SENSOR; DELAMINATION; FAILURE; RESISTIVITY; BEHAVIOR; IMPACT;
D O I
10.1016/j.compositesb.2010.08.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Carbon fiber reinforced polymer-matrix composites (CFRPs) are widely applicable in various important structural components. One of the critical issues in the successful application of CFRPs is the assessment of damage state in a particular structural component. Electrical resistance measurement is a merging non-destructive evaluation technology for real-time/on-board damage detection in CFRPs. This paper overviews the recent advances in damage detection in CFRPs using the resistance measurement. Besides the discussions on various experimental methods for self-sensing and damage detection, modeling from microscale to continuum levels for the predictions of resistances change due to the mechanical damages are also presented. Future directions in damage detection of CFRPs using the resistance method are provided. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 52 条
[1]   In situ detection of damage in CFRP laminates by electrical resistance measurements [J].
Abry, JC ;
Bochard, S ;
Chateauminois, A ;
Salvia, M ;
Giraud, G .
COMPOSITES SCIENCE AND TECHNOLOGY, 1999, 59 (06) :925-935
[2]   In-situ monitoring of damage in CFRP laminates by means of AC and DC measurements [J].
Abry, JC ;
Choi, YK ;
Chateauminois, A ;
Dalloz, B ;
Giraud, G ;
Salvia, M .
COMPOSITES SCIENCE AND TECHNOLOGY, 2001, 61 (06) :855-864
[3]   The electrical resistance response of continuous carbon fibre composite laminates to mechanical strain [J].
Angelidis, N ;
Wei, CY ;
Irving, PE .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2004, 35 (10) :1135-1147
[4]   Evaluation of defects in composite plates under convective environments using lock-in thermography [J].
Bai, W ;
Wong, BS .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (02) :142-150
[5]  
Belchamber RM., 1985, J acoustic emission, V4, P71
[6]   Thermal analysis of carbon fiber polymer-matrix composites by electrical resistance measurement [J].
Chung, DDL .
THERMOCHIMICA ACTA, 2000, 364 (1-2) :121-132
[7]  
Clerico M., 1989, International Journal of Materials & Product Technology, V4, P61
[8]  
Curtin WA, 1999, ADV APPL MECH, V36, P163
[9]   Micro/macro-mechanical approach of first ply failure in CFRP [J].
Fiedler, Bodo ;
de Jong, Claas ;
Hobbiebrunken, Thomas ;
Hojo, Masaki ;
Schulte, Karl .
JOURNAL OF MATERIALS SCIENCE, 2006, 41 (20) :6760-6767
[10]   Sensing of Damage Mechanisms in Fiber-Reinforced Composites under Cyclic Loading using Carbon Nanotubes [J].
Gao, Limin ;
Thostenson, Erik T. ;
Zhang, Zuoguang ;
Chou, Tsu-Wei .
ADVANCED FUNCTIONAL MATERIALS, 2009, 19 (01) :123-130