HEAT TRANSFER CHARACTERISTICS OF THE MULTITHREADED HELICALLY COILED TUBE GENERATOR USED IN THE ABSORPTION-COMPRESSION HYBRID REFRIGERATION CYCLE

被引:3
作者
Li, Jianbo [1 ]
Xu, Shiming [1 ]
Kong, Shaokang [1 ]
机构
[1] Dalian Univ Technol, Sch Energy & Power, Key Lab Ocean Energy Utilizat & Energy Conservat, Minist Educ, Dalian, Peoples R China
关键词
heat transfer; helically coiled tube; generator; numerical simulation; 2-PHASE FLOW; TRANSIENT; EXCHANGER;
D O I
10.1615/HeatTransRes.2014007055
中图分类号
O414.1 [热力学];
学科分类号
摘要
The generator is a key device in the absorption compression hybrid refrigeration cycle (ACH-RC). Multithreaded helically coiled tubes were used in the generator as heat exchanging elements. The heat transfer characteristic of the coil generator has been inadequately researched because of the complicated character of heat transfer between the gases from engines and the working fluid in the helically coiled tube generator. This article attempts at discussing this by numerical simulation. First, the construction parameters of the coil generator were confirmed by CFD simulation under the limited resistance to flowing gases. Then, the heat transfer models of the coil generator were developed based on some simplifications and assumptions. The heat transfer characteristic of the coil generator was simulated by difference calculus. The results show that the heat transfer area, efficient heat exchange height of the coil generator are 2.24 m(2) and 0.784 m, respectively. While the engine output reaches 180 kW, the heat transfer load of the coil generator can meet the requirement of 58.68 kW which is the load for the cooling capacity provided fully by the absorption refrigeration subcycle (ARSC). The pressure drop in the gas flowing through the coil generator is 1.65 kPa.
引用
收藏
页码:195 / 211
页数:17
相关论文
共 22 条
  • [1] FLOW IN CURVED PIPES
    BERGER, SA
    TALBOT, L
    YAO, LS
    [J]. ANNUAL REVIEW OF FLUID MECHANICS, 1983, 15 : 461 - 512
  • [2] Chen X. J., 1991, 2 PHASE FLOW HEAT TR
  • [3] Effects of coil diameter and pitch on the flow characteristics of alternative refrigerants flowing through adiabatic helical capillary tubes
    Chingulpitak, Sukkarin
    Wongwises, Somchai
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (09) : 1305 - 1311
  • [4] Transient and time-averaged boiling heat transfer of the oscillatory two-phase flow in helical coils
    Feng, ZP
    Guo, LJ
    Chen, XJ
    [J]. EXPERIMENTAL HEAT TRANSFER, 1999, 12 (04) : 329 - 346
  • [5] Guo B., 2009, ENGINE PRINCIPLE AUT
  • [6] Guo L. J., 1997, CHINESE J ENG THERMO, V18, P225
  • [7] Transient convective heat transfer of steam-water two-phase flow in a helical tube under pressure drop type oscillations
    Guo, LJ
    Feng, ZP
    Chen, XJ
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (03) : 533 - 542
  • [8] Transient convective heat transfer in a helical coiled tube with pulsatile fully developed turbulent flow
    Guo, LJ
    Chen, XJ
    Feng, ZP
    Bai, BF
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (19) : 2867 - 2875
  • [9] Thermal hydraulic study on a high-temperature gas-gas heat exchanger with helically coiled tube bundles
    Inagaki, Y
    Koiso, H
    Takumi, H
    Ioka, I
    Miyamoto, Y
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1998, 185 (2-3) : 141 - 151
  • [10] CFD analysis of single-phase flows inside helically coiled tubes
    Jayakumar, J. S.
    Mahajani, S. M.
    Mandal, J. C.
    Iyer, Kannan N.
    Vijayan, P. K.
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2010, 34 (04) : 430 - 446