Streak artefacts in Computed Tomography Urography: Comparative evaluation between two different iodinated contrast media

被引:1
作者
Pedote, Pasquale [1 ]
Cozzolino, Monica [1 ]
Nicolardi, Martina [1 ]
Accogli, Rocco Umberto [1 ]
Sardaro, Angela [1 ]
Scardapane, Arnaldo [1 ]
Ianora, Amato Antonio Stabile [1 ]
机构
[1] Univ Bari Aldo Moro, Interdisciplinary Dept Med, Sect Diagnost Imaging, Bari, Italy
关键词
artefacts; contrast media; Iodixanol; Iomeprol; urinary tract; CT; DIAGNOSIS; IOPAMIDOL;
D O I
10.1111/1754-9485.13363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction The objective of this study was to compare the frequency and entity, in computed tomography (CT) urography, of streak artefacts on the urinary tract generated by two contrast agents with a different iodine concentration and osmolarity. Methods Computed tomography scans including an excretory renal phase, performed on adult subjects in the period May-July 2020, were retrospectively evaluated in consensus by three expert radiologists, to detect any streak artefacts located in the urinary tract. Patients were administered either 1.6 mL/kg of Iodixanol 320 mgI/mL or 1.3 mL/kg of Iomeprol 400 mgI/mL. Results In total, 144 CT scans were analysed, subdivided into two groups administered either Iodixanol (71/144 (49.3%) patients) or Iomeprol (73/144 (50.7%) patients). In 41% cases, no beam hardening artefacts were found; among these, 12/59 (20.3%) patients had received Iodixanol and 47/59 (79.7%) Iomeprol. In the Iodixanol group, the mean contrast density on the renal pelvis was 2565.6 HU and streak artefacts occurred in 59/71 cases (83.1%); in 33/59 (55.9%) cases, the artefacts were marked, and in 26/59 (44.1%) minimal. In the Iomeprol group, the mean contrast density on the renal pelvis was 1666 HU and streak artefacts occurred in 26/73 cases (35.6%); in 7/26 (27%) cases, the artefacts were marked and in 19/26 (73%) minimal. Conclusion The study data demonstrate a significant difference in the attenuation values of iodine urine in the excretory system between the Iodixanol and Iomeprol group. Iodixanol induced a higher frequency and burden of artefacts, compared to Iomeprol.
引用
收藏
页码:940 / 945
页数:6
相关论文
共 46 条
[41]   Evaluation of four-dimensional cone beam computed tomography ventilation images acquired with two different linear accelerators at various gantry speeds using a deformable lung phantom [J].
Kadoya, Noriyuki ;
Nemoto, Hikaru ;
Kajikawa, Tomohiro ;
Nakajima, Yujiro ;
Kanai, Takayuki ;
Ieko, Yoshiro ;
Ikeda, Ryutaro ;
Sato, Kiyokazu ;
Dobashi, Suguru ;
Takeda, Ken ;
Jingu, Keiichi .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 :75-83
[42]   Effect of contrast material on image noise and radiation dose in adult chest computed tomography using automatic exposure control: A comparative study between 16-, 64- and 128-slice CT [J].
Paul, Jijo ;
Schell, Boris ;
Kerl, J. Matthias ;
Maentele, Werner ;
Vogl, Thomas J. ;
Bauer, Ralf W. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) :E128-E132
[43]   A technical note on intra-arterial cone-beam computed tomography for the evaluation of flow-diverter stents: Image quality differences between diluted and non-diluted contrast medium [J].
Kocer, Naci ;
Kandemirli, Sedat G. ;
Ruijters, Daniel ;
Mantatzis, Michalis ;
Kizilkilic, Osman ;
Islak, Civan .
INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (02) :164-169
[44]   Comparative Evaluation of Two-dimensional Radiography and Three Dimensional Computed Tomography Based Dose-volume Parameters for High-dose-rate Intracavitary Brachytherapy of Cervical Cancer: A Prospective Study [J].
Madan, Renu ;
Pathy, Sushmita ;
Subramani, Vellaiyan ;
Sharma, Seema ;
Mohanti, Bidhu Kalyan ;
Chander, Subhash ;
Thulkar, Sanjay ;
Kumar, Lalit ;
Dadhwal, Vatsla .
ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (11) :4717-4721
[45]   Volume perfusion computed tomography (VPCT) based evaluation of response to TACE using two different sized drug eluting beads in patients with nonresectable hepatocellular carcinoma: Impact on tumor and liver parenchymal vascularisation [J].
Kaufmann, S. ;
Horger, T. ;
Oelker, A. ;
Beck, S. ;
Schulze, M. ;
Nikolaou, K. ;
Ketelsen, D. ;
Horger, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (12) :2548-2554
[46]   Evaluation of hemodynamic imaging findings of hypervascular hepatocellular carcinoma: comparison between dynamic contrast-enhanced magnetic resonance imaging using radial volumetric imaging breath-hold examination with k-space-weighted image contrast reconstruction and dynamic computed tomography during hepatic arteriography [J].
Kurozumi, Masahiro ;
Fujinaga, Yasunari ;
Kitou, Yoshihiro ;
Yamada, Akira ;
Ohya, Ayumi ;
Adachi, Yasuo ;
Tsukahara, Yoshinori ;
Nickel, Marcel D. ;
Maruyama, Katsuya ;
Uehara, Takeshi ;
Miyagawa, Shin-ichi ;
Kadoya, Masumi .
JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (04) :295-302