Diagnostic Performance of Dynamic Myocardial Perfusion Imaging Using Dual-Source Computed Tomography

被引:26
|
作者
Kitagawa, Kakuya [1 ]
Nakamura, Satoshi [2 ]
Ota, Hideki [3 ]
Ogawa, Ryo [4 ]
Shizuka, Takehito [5 ]
Kubo, Tadahiro [6 ]
Yi, Yan [7 ]
Ito, Tatsuro [8 ]
Nagasawa, Naoki [2 ]
Omori, Taku [9 ]
Nakamori, Shiro [9 ]
Kurita, Tairo [10 ]
Sugisawa, Jun [10 ]
Hatori, Naoki [5 ]
Nakashima, Hitoshi [6 ]
Wang, Yining [7 ]
Kido, Teruhito [4 ]
Watanabe, Kouki [11 ]
Matsumoto, Yasuharu [10 ,12 ]
Dohi, Kaoru [9 ]
Sakuma, Hajime [13 ]
机构
[1] Mie Univ, Grad Sch Med, Dept Adv Diagnost Imaging, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[2] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[3] Tohoku Univ Hosp, Dept Diagnost Radiol, Sendai, Miyagi, Japan
[4] Ehime Univ, Dept Radiol, Grad Sch Med, Matsuyama, Ehime, Japan
[5] Natl Hosp Org, Takasaki Gen Med Ctr, Dept Cardiol, Takasaki, Gumma, Japan
[6] Natl Hosp Org, Kagoshima Med Ctr, Dept Cardiovasc Med, Kagoshima, Japan
[7] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
[8] Kobe Univ, Grad Sch Med, Dept Cardiovasc Med, Kobe, Hyogo, Japan
[9] Mie Univ, Dept Cardiol & Nephrol, Grad Sch Med, Tsu, Mie, Japan
[10] Tohoku Univ, Dept Cardiovasc Med, Sch Med, Sendai, Miyagi, Japan
[11] Saiseikai Matsuyama Hosp, Div Cardiol, Matsuyama, Ehime, Japan
[12] Int Univ Hlth & Welf, Shioya Hosp, Dept Cardiovasc Med, Yaita, Japan
[13] Mie Univ, Dept Radiol, Grad Sch Med, Tsu, Mie, Japan
关键词
4-dimensional computed tomography; coronary artery disease; multicenter study; myocardial ischemia; myocardial perfusion imaging; FRACTIONAL FLOW RESERVE; CORONARY-ARTERY-DISEASE; BLOOD-FLOW; PROGNOSTIC VALUE; MEDICAL THERAPY; STENOSIS; CT; ANGIOGRAPHY; REVASCULARIZATION; ACCURACY;
D O I
10.1016/j.jacc.2021.08.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
RESULTS The study protocol was completed in 157 participants, and hemodynamically significant stenosis was detected in 76 of 157 patients (48%) and 112 of 442 vessels (25%). According to receiver-operating characteristic curve analysis, adding dynamic CTP to CTA significantly increased the area under the curve from 0.65 (95% CI: 0.57-0.72) to 0.74 (95% CI: 0.66-0.81; P 1/4 0.011) on the patient level, with decreased sensitivity (93% vs 72%; P < 0.001), improved specificity (36% vs 75%; P < 0.001), and improved overall accuracy (64% vs 74%; P < 0.001).
引用
收藏
页码:1937 / 1949
页数:13
相关论文
共 50 条
  • [1] Dynamic dual-source computed tomography imaging for myocardial perfusion
    Li, Allen
    Chan, Y. H.
    Wu, B. E.
    Lam, C. S.
    HONG KONG MEDICAL JOURNAL, 2019, 25 (01)
  • [2] Cardiac myocardial perfusion imaging using dual source computed tomography
    Blankstein, Ron
    Okada, David R.
    Rocha-Filho, Jose A.
    Rybicki, Frank J.
    Brady, Thomas J.
    Cury, Ricardo C.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 209 - 216
  • [3] Adenosine-Induced Stress Myocardial Perfusion Imaging Using Dual-Source Cardiac Computed Tomography
    Blankstein, Ron
    Shturman, Leon D.
    Rogers, Ian S.
    Rocha-Filho, Jose A.
    Okada, David R.
    Sarwar, Ammar
    Soni, Anand V.
    Bezerra, Hiram
    Ghoshhajra, Brian B.
    Petranovic, Milena
    Loureiro, Ricardo
    Feuchtner, Gudrun
    Gewirtz, Henry
    Hoffmann, Udo
    Mamuya, Wilfred S.
    Brady, Thomas J.
    Cury, Ricardo C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (12) : 1072 - 1084
  • [4] Diagnostic Accuracy of Endocardial-to-Epicardial Myocardial Blood Flow Ratio for the Detection of Significant Coronary Artery Disease With Dynamic Myocardial Perfusion Dual-Source Computed Tomography
    Goto, Yoshitaka
    Kitagawa, Kakuya
    Uno, Mio
    Nakamori, Shiro
    Ito, Tatsuro
    Nagasawa, Naoki
    Dohi, Kaoru
    Sakuma, Hajime
    CIRCULATION JOURNAL, 2017, 81 (10) : 1477 - +
  • [5] Cardiac myocardial perfusion imaging using dual source computed tomography
    Ron Blankstein
    David R. Okada
    Jose A. Rocha-Filho
    Frank J. Rybicki
    Thomas J. Brady
    Ricardo C. Cury
    The International Journal of Cardiovascular Imaging, 2009, 25 : 209 - 216
  • [6] Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT
    Takafuji, Masafumi
    Kitagawa, Kakuya
    Ishida, Masaki
    Goto, Yoshitaka
    Nakamura, Satoshi
    Nagasawa, Naoki
    Sakuma, Hajime
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (01) : 58 - 67
  • [7] Diagnostic performance of deep learning algorithm for analysis of computed tomography myocardial perfusion
    Muscogiuri, Giuseppe
    Chiesa, Mattia
    Baggiano, Andrea
    Spadafora, Pierino
    De Santis, Rossella
    Guglielmo, Marco
    Scafuri, Stefano
    Fusini, Laura
    Mushtaq, Saima
    Conte, Edoardo
    Annoni, Andrea
    Formenti, Alberto
    Mancini, Maria Elisabetta
    Ricci, Francesca
    Ariano, Francesco Paolo
    Spiritigliozzi, Luigi
    Babbaro, Mario
    Mollace, Rocco
    Maragna, Riccardo
    Giacari, Carlo Maria
    Andreini, Daniele
    Guaricci, Andrea Igoren
    Colombo, Gualtiero I.
    Rabbat, Mark G.
    Pepi, Mauro
    Sardanelli, Francesco
    Pontone, Gianluca
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (09) : 3119 - 3128
  • [8] Comparison of automated beam hardening correction (ABHC) algorithms for myocardial perfusion imaging using computed tomography
    Levi, Jacob
    Wu, Hao
    Eck, Brendan L.
    Fahmi, Rachid
    Vembar, Mani
    Dhanantwar, Amar
    Fares, Anas
    Bezerra, Hiram G.
    Wilson, David L.
    MEDICAL PHYSICS, 2021, 48 (01) : 287 - 299
  • [9] Clinical Outcomes of Dynamic Computed Tomography Myocardial Perfusion Imaging Combined With Coronary Computed Tomography Angiography Versus Coronary Computed Tomography Angiography-Guided Strategy
    Yu, Mengmeng
    Shen, Chengxing
    Dai, Xu
    Lu, Zhigang
    Wang, Yining
    Lu, Bin
    Zhang, Jiayin
    CIRCULATION-CARDIOVASCULAR IMAGING, 2020, 13 (01) : E009775
  • [10] Optimal Scan Time for Single-Phase Myocardial Computed Tomography Perfusion to Detect Myocardial Ischemia - Derivation Cohort From Dynamic Myocardial Computed Tomography Perfusion
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Uetani, Teruyoshi
    Fukuyama, Naoki
    Yokoi, Takahiro
    Nishiyama, Hikaru
    Kido, Tomoyuki
    Miyagawa, Masao
    Mochizuki, Teruhito
    CIRCULATION JOURNAL, 2016, 80 (12) : 2506 - 2512