Poly(Thiophene)/Graphene Oxide-Modified Electrodes for Amperometric Glucose Biosensing

被引:5
|
作者
Pilo, Maria, I [1 ]
Baluta, Sylwia [2 ]
Loria, Anna C. [1 ]
Sanna, Gavino [1 ]
Spano, Nadia [1 ]
机构
[1] Univ Sassari, Dipartimento Sci Chim Fis Matemat & Nat, Via Vienna 2, I-07100 Sassari, Italy
[2] Wroclaw Univ Sci & Technol, Fac Chem, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
amperometric biosensor; conducting polymers; poly(thiophene); glucose oxidase; graphene oxide; REDUCED GRAPHENE OXIDE; CONDUCTING POLYMER; FILMS; SENSORS; ACID; COPOLYMERIZATION; POLYTHIOPHENE; NANOPARTICLES; SELECTIVITY; DOPAMINE;
D O I
10.3390/nano12162840
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The availability of fast and non-expensive analytical methods for the determination of widespread interest analytes such as glucose is an object of large relevance; this is so not only in the field of analytical chemistry, but also in medicinal and in food chemistry. In this context, electrochemical biosensors have been proposed in different arrangements, according to the mode of electron transfer between the bioreceptor and the electrode. An efficient immobilization of an enzyme on the electrode surface is essential to assure satisfactory analytical performances of the biosensor in terms of sensitivity, limit of detection, selectivity, and linear range of employment. Here, we report the use of a thiophene monomer, (2,5-di(2-thienyl)thieno [3,2-b]thiophene (dTT-bT), as a precursor of an electrogenerated conducting film to immobilize the glucose oxidase (GOx) enzyme on Pt, glassy carbon (GC), and Au electrode surfaces. In addition, the polymer film electrochemically synthetized on a glassy carbon electrode was modified with graphene oxide before the deposition of GOx; the analytical performances of both the arrangements (without and with graphene oxide) in the glucose detection were compared. The biosensor containing graphene oxide showed satisfactory values of linear dynamic range (1.0-10 mM), limit of detection (0.036 mM), and sensitivity (9.4 mu A mM(-1) cm(-2)). Finally, it was tested in the determination of glucose in fruit juices; the interference from fructose, saccharose, and ascorbic acid was evaluated.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Glucose sensing by a glassy carbon electrode modified with glucose oxidase/chitosan/graphene oxide nanofibers
    Mehdizadeh, Bentolhoda
    Maleknia, Laleh
    Amirabadi, Amir
    Shabani, Mohammad
    DIAMOND AND RELATED MATERIALS, 2020, 109
  • [22] Enhanced performance of pyrrolic N-doped reduced graphene oxide-modified glassy carbon electrodes for dopamine sensing
    Wiench, Piotr
    Gonzalez, Zoraida
    Gryglewicz, Stanislaw
    Menendez, Rosa
    Gryglewicz, Grazyna
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 852
  • [23] ONE-POT ELECTROCHEMICAL FABRICATION OF SnO-REDUCED GRAPHENE OXIDE ELECTRODES FOR AMPEROMETRIC SENSING OF DOPAMINE
    Dogan, Hulya Ozturk
    Urhan, Bingul Kurt
    Ozer, Tuba Oznuluer
    Demir, Umit
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2021, 40 (02) : 299 - 306
  • [24] Graphene Oxide-Modified Aramid Fibers for Reinforcing Epoxy Resin Matrixes
    Tian, Jin
    An, Lizhou
    Tan, Yefa
    Xu, Ting
    Li, Xiaotun
    Chen, Guanxiu
    ACS APPLIED NANO MATERIALS, 2021, 4 (09) : 9595 - 9605
  • [25] Highly Sensitive and Selective Glucose Biosensing at Carbon Paste Electrodes Modified with Electrogenerated Magnetite Nanoparticles and Glucose Oxidase
    Comba, Fausto N.
    Rubianes, Maria D.
    Cabrera, Lourdes
    Gutierrez, Silvia
    Herrasti, Pilar
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2010, 22 (14) : 1566 - 1572
  • [26] Graphene oxide-modified ZnO particles: synthesis, characterization, and antibacterial properties
    Zhong, Linlin
    Yun, Kyusik
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2015, 10 : 79 - 92
  • [27] Reduced graphene oxide-modified biochar electrodes via electrophoretic deposition with high rate capability for supercapacitors
    Baozhen Rui
    Mengyue Yang
    Lei Zhang
    Yuan Jia
    Ying Shi
    Rebecca Histed
    Yiliang Liao
    Jianjun Xie
    Fang Lei
    Lingcong Fan
    Journal of Applied Electrochemistry, 2020, 50 : 407 - 420
  • [28] A highly sensitive electrochemical biosensor for phenol derivatives using a graphene oxide-modified tyrosinase electrode
    Wang, Yue
    Zhai, Fengge
    Hasebe, Yasushi
    Jia, Hongmin
    Zhang, Zhiqiang
    BIOELECTROCHEMISTRY, 2018, 122 : 174 - 182
  • [29] Reduced graphene oxide-modified biochar electrodes via electrophoretic deposition with high rate capability for supercapacitors
    Rui, Baozhen
    Yang, Mengyue
    Zhang, Lei
    Jia, Yuan
    Shi, Ying
    Histed, Rebecca
    Liao, Yiliang
    Xie, Jianjun
    Lei, Fang
    Fan, Lingcong
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2020, 50 (04) : 407 - 420
  • [30] Cost-effective quantification of uric acid using niobium oxide and graphene oxide-modified pencil-drawn electrodes on PVC substrates
    Saraiva, Douglas P. M.
    Ferreira, Bruno
    Ribeiro, Leonardo M. A.
    Paixao, Thiago R. L. C.
    Bertotti, Mauro
    ANALYTICAL METHODS, 2024, 16 (43) : 7407 - 7412