"Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy

被引:21
作者
Yuan, Zilong [1 ,2 ]
Rong, Yi [1 ]
Benedict, Stanley H. [1 ]
Daly, Megan E. [1 ]
Qiu, Jianfeng [3 ]
Yamamoto, Tokihiro [1 ]
机构
[1] Univ Calif Davis, Comprehens Canc Ctr, Dept Radiat Oncol, Sacramento, CA 95817 USA
[2] Huazhong Univ Sci & Technol, Hubei Canc Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Hubei, Peoples R China
[3] Shandong First Med Univ & Shandong Acad Med Sci, Med Engn & Technol Res Ctr, Tai An, Shandong, Peoples R China
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2020年 / 21卷 / 01期
基金
国家重点研发计划;
关键词
adaptive radiotherapy; CBCT; dose of the day; virtual CT; ADAPTIVE RADIOTHERAPY; PROTON THERAPY; RTOG; 0617; CT; CBCT; HEAD; RECALCULATION; FEASIBILITY; ALGORITHM; ACCURACY;
D O I
10.1002/acm2.12793
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the "dose of the day". The purpose of this study is to investigate the "dose of the day" calculation accuracy based on CBCT and deformable image registration (DIR) for lung cancer radiotherapy. Methods A total of 12 lung cancer patients were identified, for which daily CBCT imaging was performed for treatment positioning. A re-planning CT (rCT) was acquired after 20 Gy for all patients. A virtual CT (vCT) was created by deforming initial planning CT (pCT) to the simulated CBCT that was generated from deforming CBCT to rCT acquired on the same day. Treatment beams from the initial plan were copied to the vCT and rCT for dose calculation. Dosimetric agreement between vCT-based and rCT-based accumulated doses was evaluated using the Bland-Altman analysis. Results Mean differences in dose-volume metrics between vCT and rCT were smaller than 1.5%, and most discrepancies fell within the range of +/- 5% for the target volume, lung, esophagus, and heart. For spinal cord D-max, a large mean difference of -5.55% was observed, which was largely attributed to very limited CBCT image quality (e.g., truncation artifacts). Conclusion This study demonstrated a reasonable agreement in dose-volume metrics between dose accumulation based on vCT and rCT, with the exception for cases with poor CBCT image quality. These findings suggest potential utility of vCT for providing a reasonable estimate of the "dose of the day", and thus facilitating the process of ART for lung cancer.
引用
收藏
页码:88 / 94
页数:7
相关论文
共 34 条
[1]   Bladder dose accumulation based on a biomechanical deformable image registration algorithm in volumetric modulated arc therapy for prostate cancer [J].
Andersen, E. S. ;
Muren, L. P. ;
Sorensen, T. S. ;
Noe, K. O. ;
Thor, M. ;
Petersen, J. B. ;
Hoyer, M. ;
Bentzen, L. ;
Tanderup, K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :7089-7100
[2]   Feasibility of CBCT-based proton dose calculation using a histogram-matching algorithm in proton beam therapy [J].
Arai, Kazuhiro ;
Kadoya, Noriyuki ;
Kato, Takahiro ;
Endo, Hiromitsu ;
Komori, Shinya ;
Abe, Yoshitomo ;
Nakamura, Tatsuya ;
Wada, Hitoshi ;
Kikuchi, Yasuhiro ;
Takai, Yoshihiro ;
Jingu, Keiichi .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 :68-76
[3]   Standard-dose versus high-dose conformal radiotherapy with concurrent and consolidation carboplatin plus paclitaxel with or without cetuximab for patients with stage IIIA or IIIB non-small-cell lung cancer (RTOG 0617): a randomised, two-by-two factorial phase 3 study [J].
Bradley, Jeffrey D. ;
Paulus, Rebecca ;
Komaki, Ritsuko ;
Masters, Gregory ;
Blumenschein, George ;
Schild, Steven ;
Bogart, Jeffrey ;
Hu, Chen ;
Forster, Kenneth ;
Magliocco, Anthony ;
Kavadi, Vivek ;
Garces, Yolanda I. ;
Narayan, Samir ;
Iyengar, Puneeth ;
Robinson, Cliff ;
Wynn, Raymond B. ;
Koprowski, Christopher ;
Meng, Joanne ;
Beitler, Jonathan ;
Gaur, Rakesh ;
Curran, Walter, Jr. ;
Choy, Hak .
LANCET ONCOLOGY, 2015, 16 (02) :187-199
[4]   Toward adaptive radiotherapy for lung patients: feasibility study on deforming planning CT to CBCT to assess the impact of anatomical changes on dosimetry [J].
Cole, A. J. ;
Veiga, C. ;
Johnson, U. ;
D'Souza, D. ;
Lalli, N. K. ;
McClelland, J. R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15)
[5]   ARE THE RESULTS OF RTOG 0617 MYSTERIOUS? [J].
Cox, James D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (03) :1042-1044
[6]   Accuracy of dose calculations on kV cone beam CT images of lung cancer patients [J].
de Smet, Mariska ;
Schuring, Danny ;
Nijsten, Sebastiaan ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2016, 43 (11) :5934-5941
[7]   Comparison of CT number calibration techniques for CBCT-based dose calculation [J].
Dunlop, Alex ;
McQuaid, Dualta ;
Nill, Simeon ;
Murray, Julia ;
Poludniowski, Gavin ;
Hansen, Vibeke N. ;
Bhide, Shreerang ;
Nutting, Christopher ;
Harrington, Kevin ;
Newbold, Kate ;
Oelfke, Uwe .
STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (12) :970-978
[8]   Escalation and Intensification of Radiotherapy for Stage III Non-small Cell Lung Cancer: Opportunities for Treatment Improvement [J].
Fenwick, J. D. ;
Nahum, A. E. ;
Malik, Z. I. ;
Eswar, C. V. ;
Hatton, M. Q. ;
Laurence, V. M. ;
Lester, J. F. ;
Landau, D. B. .
CLINICAL ONCOLOGY, 2009, 21 (04) :343-360
[9]   Feasibility of CBCT-based dose calculation: Comparative analysis of HU adjustment techniques [J].
Fotina, Irina ;
Hopfgartner, Johannes ;
Stock, Markus ;
Steininger, Thomas ;
Luetgendorf-Caucig, Carola ;
Georg, Dietmar .
RADIOTHERAPY AND ONCOLOGY, 2012, 104 (02) :249-256
[10]   Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy [J].
Guan, Huaiqun ;
Dong, Hang .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20) :6239-6250