Partially Melted Ti6Al4V Particles Increase Bacterial Adhesion and Inhibit Osteogenic Activity on 3D-printed Implants: An In Vitro Study

被引:33
作者
Xie, Kai [1 ]
Guo, Yu [1 ]
Zhao, Shuang [1 ]
Wang, Lei [1 ]
Wu, Junxiang [1 ]
Tan, Jia [1 ]
Yang, Yangzi [1 ]
Wu, Wen [1 ]
Jiang, Wenbo [2 ]
Hao, Yongqiang [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Shanghai Peoples Hosp 9, Shanghai Key Lab Orthopaed Implants,Dept Orthopae, 639 Zhizaoju Rd, Shanghai 200011, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Clin & Translat Res Ctr 3D Printing Technol, Sch Med, Shanghai, Peoples R China
基金
国家重点研发计划;
关键词
POROUS TITANIUM; ENHANCED OSSEOINTEGRATION; ANTIBACTERIAL ACTIVITY; BIOFILM FORMATION; ALLOY IMPLANTS; SURFACE; SCAFFOLDS; LASER; BIOCOMPATIBILITY; IMPACT;
D O I
10.1097/CORR.0000000000000954
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background A porous Ti6Al4V implant that is manufactured using selective laser melting (SLM) has broad potential applications in the field of orthopaedic implants. The pore structure of the SLM porous Ti6Al4V implant allows for cell migration and osteogenic differentiation, which is favorable for bone ingrowth and osseointegration. However, it is unclear whether the pore structure and partially melted Ti6Al4V particles on a SLM porous Ti6Al4V implant will increase bacterial adhesion and, perhaps, the risk of implant-related infection. Questions/purposes (1) Is there more bacterial adhesion and colonization on SLM porous Ti6Al4V implants than on polished orthopaedic implants? (2) Do partially melted Ti6Al4V particles on SLM porous Ti6Al4V implants reduce human bone mesenchymal stem cells (hBMSCs) adhesion, viability, and activity? Methods To determine bacterial adhesion and biofilm formation, we incubated five different Ti6Al4Vdiscs (polished, grit-blasted, plasma-sprayed, particle SLM porous, and nonparticle SLM porous discs) with methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli. Bacterial coverage on the surface of the five different Ti6Al4V discs were evaluated based on scanning electron microscopy (SEM) images quantitatively. In addition, a spread-plate method was used to quantitatively evaluate the bacterial adhesion on those implants. The biofilm formation was stained with crystal violet and semi-quantitatively determined with a microplate reader. The morphology and adhesion of hBMSCs on the five Ti6Al4V discs were observed with SEM. The cell viability was quantitatively evaluated with a Cell Counting Kit-8 assay. In addition, the osteogenic activity was determined in vitro with a quantitatively alkaline phosphatase activity assay and alizarin-red staining. For semiquantitative analysis, the alizarin-red stained mineralized nodules were dissolved and determined with a microplate reader. Results The polished discs had the lowest MRSA adhesion (8.3% +/- 2.6%) compared with grit-blasted (19.1% +/- 3.9%; p = 0.006), plasma-sprayed (38.5% +/- 5.3%; p < 0.001), particle (23.1% +/- 2.8%; p < 0.001), and nonparticle discs (15.7% +/- 2.5%; p = 0.003). Additionally, when comparing the two SLM discs, we found that particle discs had higher bacterial coverage than nonparticle discs (23.1% +/- 2.8% versus 15.7% +/- 2.5%; p = 0.020). An E coli analysis showed similar results, with the higher adhesion to particle SLM discs than to nonparticle discs (20.7% +/- 4.2% versus 14.4% +/- 3.6%; p = 0.011). In addition, on particle SLM porous discs, bacterial colonies were localized around the partially melted Ti6Al4V particles, based on SEM images. After a 7-day incubation period, the cell viability in the particle group (optical density value 0.72 +/- 0.05) was lower than that in the nonparticle groups (optical density value: 0.87 +/- 0.08; p = 0.003). Alkaline phosphatase activity, as a marker of osteogenic differentiation, was lower in the particle group than in the nonparticle group (1.32 +/- 0.12 U/mL versus 1.58 +/- 0.09 U/mL; p = 0.012). Conclusion Higher bacterial adhesion was observed on SLM porous discs than on polished discs. The partially melted Ti6Al4Vparticles on SLM porous discs not only enhanced bacterial adhesion but also inhibited the osteogenic activity of hBMSCs. Postprocessing treatment is necessary to remove partially melted Ti6Al4V particles on an SLM implant before further use. Additional studies are needed to determine whether an SLM porous Ti6Al4V implant increases the risk of implant-related infection in vivo.
引用
收藏
页码:2772 / 2782
页数:11
相关论文
共 38 条
[1]   Implant infections: adhesion, biofilm formation and immune evasion [J].
Arciola, Carla Renata ;
Campoccia, Davide ;
Montanaro, Lucio .
NATURE REVIEWS MICROBIOLOGY, 2018, 16 (07) :397-409
[2]   The effect of dental restorative materials on dental biofilm [J].
Auschill, TM ;
Arweiler, NB ;
Brecx, M ;
Reich, E ;
Sculean, A ;
Netuschil, L .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2002, 110 (01) :48-53
[3]   Tobacco Use and Risk of Wound Complications and Periprosthetic Joint Infection: A Systematic Review and Meta-Analysis of Primary Total Joint Arthroplasty Procedures [J].
Bedard, Nicholas A. ;
Demik, David E. ;
Owens, Jessell M. ;
Glass, Natalie A. ;
DeBerg, Jennifer ;
Callaghan, John J. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (02) :385-+
[4]   Biofilm Formation on Dental Restorative and Implant Materials [J].
Busscher, H. J. ;
Rinastiti, M. ;
Siswomihardjo, W. ;
van der Mei, H. C. .
JOURNAL OF DENTAL RESEARCH, 2010, 89 (07) :657-665
[5]   Impact of engineered surface microtopography on biofilm formation of Staphylococcus aureus [J].
Chung, Kenneth K. ;
Schumacher, James F. ;
Sampson, Edith M. ;
Burne, Robert A. ;
Antonelli, Patrick J. ;
Brennana, Anthony B. .
BIOINTERPHASES, 2007, 2 (02) :89-94
[6]   Promising characteristics of gradient porosity Ti-6Al-4V alloy prepared by SLM process [J].
Fousova, Michaela ;
Vojtech, Dalibor ;
Kubasek, Jiri ;
Jablonska, Eva ;
Fojt, Jaroslav .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 69 :368-376
[7]   Biomaterial-centered infection - Microbial adhesion versus tissue integration - (Reprinted from Science, vol. 237, pg. 1588-1595, 1987) [J].
Gristina, A ;
Sherk, HH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (427) :4-12
[8]   In Vitro and in Vivo Study of 3D-Printed Porous Tantalum Scaffolds for Repairing Bone Defects [J].
Guo, Yu ;
Xie, Kai ;
Jiang, Wenbo ;
Wang, Lei ;
Li, Guoyuan ;
Zhao, Shuang ;
Wu, Wen ;
Hao, Yongqiang .
ACS BIOMATERIALS SCIENCE & ENGINEERING, 2019, 5 (02) :1123-1133
[9]   The impact of structure dimensions on initial bacterial adhesion [J].
Helbig, Ralf ;
Guenther, Denise ;
Friedrichs, Jens ;
Roessler, Florian ;
Lasagni, Andres ;
Werner, Carsten .
BIOMATERIALS SCIENCE, 2016, 4 (07) :1074-1078
[10]   Proinflammatory and osteolysis- inducing effects of 3D printing Ti6Al4V particles in vitro and in vivo [J].
Li, Cuidi ;
Jiang, Chuan ;
Peng, Mingzheng ;
Li, Tao ;
Yang, Zezheng ;
Liu, Zhiyuan ;
Li, Ning ;
Wang, Chengtao ;
Dai, Kerong ;
Wang, Jinwu .
RSC ADVANCES, 2018, 8 (04) :2229-2239