Novel Y(III) PVC-based membrane microelectrode based on a new S-N Schiff's base

被引:98
|
作者
Ganjali, MR [1 ]
Daftari, A
Nourozi, P
Salavati-Niasari, M
机构
[1] Univ Tehran, Dept Chem, Tehran, Iran
[2] Kashan Univ, Dept Chem, Kashan, Iran
关键词
yttrium; microelectrode; potentiometry; Schiff's base;
D O I
10.1081/AL-120021533
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new Schiff's base with sulfur and nitrogen donor atoms (2-({(E)1,2-diphenyl-2-[(2-2-sulfanylphenyl)imino]ethylidene} amino)-1-benzenethiol, DSAB) was used as a membrane-active component to prepare a Y(III)-selective polymeric membrane microelectrode. The electrode exhibits a Nernstian response toward Y(III) ions over a wide concentration range (1.0 X 10(-2)-1.0 x 10(-7)M), with a detection limit of 7.0 X 10(-8) M (6.2 mug/mL). It has a very fast response time < 5s and can be used for at least one month without any considerable divergence in potentials. The proposed membrane sensor revealed very good selectivity toward yttrium over a wide variety of other metal ions including alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 4.0-9.0. It was used as an indicator electrode in the potentiometric titration of yttrium ions with EDTA. The proposed micro sensor was also used to direct determination of yttrium in an yttrium-aluminum alloy sample.
引用
收藏
页码:1511 / 1522
页数:12
相关论文
共 50 条
  • [21] Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base
    Ganjali, Mohammad Reza
    Norouzi, P.
    Faridbod, F.
    Ghorbani, M.
    Adib, M.
    ANALYTICA CHIMICA ACTA, 2006, 569 (1-2) : 35 - 41
  • [22] Novel PVC-based membrane sensors selective for vanadyl ions
    Jain, AK
    Gupta, VK
    Singh, LP
    Khurana, U
    TALANTA, 1998, 46 (06) : 1453 - 1460
  • [23] Construction of a highly selective PVC-based membrane sensor for Ce(III) ions
    Zamani, Hassan Ali
    Ganjali, Mohammad Reza
    Adib, Mahdi
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 120 (02): : 545 - 550
  • [24] Lanthanide Recognition: an Asymetric Lanthanum(III) Microsensor Based on a New Schiff's Base
    Ganjali, Mohammad Reza
    Ganjali, Hamed
    Larijani, Bagher
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (07): : 914 - 922
  • [25] A novel Mn2+PVC membrane electrode based on a recently synthesized Schiff base
    Mashhadizadeh, Mohammad Hossein
    Taheri, Ehsan Pour
    Sheikhshoaie, Iran
    TALANTA, 2007, 72 (03) : 1088 - 1092
  • [26] Effect of Conditioning Time on a Novel PVC-based Membrane for ChemFET sensitive to Histamine
    Esa, S. F. Mohammed
    Lee, Khuan Y.
    Jarmin, R.
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 572 - 577
  • [27] PVC-MEMBRANE POTENTIOMETRIC SENSORS BASED ON A RECENTLY SYNTHESIZED SCHIFF BASE FOR Fe(III) ION
    Sheikhshoaie, Iran
    Shamspur, Tayebeh
    Mostafavi, Ali
    Ebrahimipur, S. Yousef
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2012, 26 (01) : 65 - 72
  • [28] Ruthenium(III) Schiff's base complex as novel chloride selective membrane sensor
    Ganjali, MR
    Pourjavid, MR
    Rezapour, M
    Poursaberi, T
    Daftari, A
    Salavati-Niasari, M
    ELECTROANALYSIS, 2004, 16 (11) : 922 - 927
  • [29] Aluminium (III)-selective PVC membrane sensor based on a Schiff base complex of N,N′-bis (salicylidene)-1, 2-cyclohexanediamine
    Gupta, Vinod K.
    Goyal, Rajendra N.
    Jain, Ajay K.
    Sharma, Ram A.
    ELECTROCHIMICA ACTA, 2009, 54 (11) : 3218 - 3224
  • [30] PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine
    Amini, MK
    Shahrokhian, S
    Tangestaninejad, S
    ANALYTICAL CHEMISTRY, 1999, 71 (13) : 2502 - 2505