Reliability testing of the Larsen and Sharp classifications for rheumatoid arthritis of the elbow

被引:4
作者
Jew, Nicholas B. [1 ]
Hollins, Anthony M. [2 ]
Mauck, Benjamin M. [1 ]
Smith, Richard A. [1 ]
Azar, Frederick M. [1 ]
Miller, Robert H., III [1 ]
Throckmorton, Thomas W. [1 ]
机构
[1] Univ Tennessee, Campbell Clin, Dept Orthopaed Surg & Biomed Engn, Memphis, TN USA
[2] Memphis Shoulder & Orthoped Surg, Memphis, TN USA
关键词
Elbow; rheumatoid arthritis; classification; radiographic; reliability; severity; progression; RADIOLOGIC ASSESSMENT; SCORING METHODS; PROGRESSION;
D O I
10.1016/j.jse.2016.07.074
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Two popular systems for classifying rheumatoid arthritis affecting the elbow are the Larsen and Sharp schemes. To our knowledge, no study has investigated the reliability of these 2 systems. We compared the intraobserver and interobserver agreement of the 2 systems to determine whether one is more reliable than the other. Methods: The radiographs of 45 patients diagnosed with rheumatoid arthritis affecting the elbow were evaluated. Anteroposterior and lateral radiographs were deidentified and distributed to 6 evaluators (4 fellowship-trained upper extremity surgeons and 2 orthopedic trainees). Each evaluator graded all 45 radiographs according to the Larsen and Sharp scoring methods on 2 occasions, at least 2 weeks apart. Results: Overall intraobserver reliability was 0.93 (95% confidence interval [CI], 0.90-0.95) for the Larsen system and 0.92 (95% CI, 0.86-0.96) for the Sharp classification, both indicating substantial agreement. Overall interobserver reliability was 0.70 (95% CI, 0.60-0.80) for the Larsen classification and 0.68 (95% CI, 0.54-0.81) for the Sharp system, both indicating good agreement. There were no significant differences in the intraobserver or interobserver reliability of the systems overall and no significant differences in reliability between attending surgeons and trainees for either classification system. Conclusion: The Larsen and Sharp systems both show substantial intraobserver reliability and good interobserver agreement for the radiographic classification of rheumatoid arthritis affecting the elbow. Differences in training level did not result in substantial variances in reliability for either system. We conclude that both systems can be reliably used to evaluate rheumatoid arthritis of the elbow by observers of varying training levels. (C) 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:140 / 143
页数:4
相关论文
共 19 条
[1]  
Boini S, 2001, ANN RHEUM DIS, V60, P817
[2]   DISCRIMINATIVE POWER OF LARSENS GRADING SYSTEM FOR ASSESSING THE COURSE OF RHEUMATOID-ARTHRITIS [J].
DECARVALHO, A .
ACTA RADIOLOGICA-DIAGNOSIS, 1981, 22 (01) :77-80
[3]   ASSESSMENT OF RADIOLOGIC PROGRESSION IN RHEUMATOID-ARTHRITIS - A RANDOMIZED, CONTROLLED TRIAL [J].
FRIES, JF ;
BLOCH, DA ;
SHARP, JT ;
MCSHANE, DJ ;
SPITZ, P ;
BLUHM, GB ;
FORRESTER, D ;
GENANT, H ;
GOFTON, P ;
RICHMAN, S ;
WEISSMAN, B ;
WOLFE, F .
ARTHRITIS AND RHEUMATISM, 1986, 29 (01) :1-9
[4]  
GSCHWEND N, 1980, SURG TREATMENT RHEUM, P45
[5]   RELIABILITY OF 3 METHODS OF RADIOLOGIC ASSESSMENT IN PATIENTS WITH RHEUMATOID-ARTHRITIS [J].
GUTH, A ;
COSTE, J ;
CHAGNON, S ;
LACOMBE, P ;
PAOLAGGI, JB .
INVESTIGATIVE RADIOLOGY, 1995, 30 (03) :181-185
[6]  
HASTINGS DE, 1982, J BONE JOINT SURG BR, V64, P634
[7]  
JAECKEL WH, 1990, Z RHEUMATOL, V49, P151
[8]   RADIOGRAPHIC EVALUATION OF RHEUMATOID-ARTHRITIS AND RELATED CONDITIONS BY STANDARD REFERENCE FILMS [J].
LARSEN, A ;
DALE, K ;
EEK, M .
ACTA RADIOLOGICA-DIAGNOSIS, 1977, 18 (04) :481-491
[9]  
Lehtinen JT, 2001, J RHEUMATOL, V28, P70
[10]  
LJUNG P, 1995, J ORTHOP RHEUMATOL, V8, P32