Characteristics of Langmuir probe in low temperature, weakly magnetized plasmas

被引:0
|
作者
Wu, LQ [1 ]
Liu, WD [1 ]
Xie, JL [1 ]
Yu, Z [1 ]
Tao, L [1 ]
Ouyang, L [1 ]
Wang, Y [1 ]
Zhao, K [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230027, Peoples R China
关键词
weakly magnetized plasmas; Langrimir probe;
D O I
暂无
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The systematic Langmuir probe measurements for a weakly magnetized plasma have been carried out in the Linear Magnetized Plasma Device for different magnetic fields. By comparing the ion current density of probes with different sizes, the sheath thickness can be evaluated. It is found that while the ratio of cylindrical probe's dimension to ion Larmor radius is not more than 2, the model of probe for non-magnetized plasma is still applicable.
引用
收藏
页码:1615 / 1618
页数:4
相关论文
共 50 条
  • [41] Full fluid moment model for low temperature magnetized plasmas
    Sahu, Rupali
    Mansour, Adnan R.
    Hara, Kentaro
    PHYSICS OF PLASMAS, 2020, 27 (11)
  • [42] Collisionless dissipation at the boundary sheath of magnetized low temperature plasmas
    Krueger, Dennis
    Koehn, Kevin
    Xu, Liang
    Eremin, Denis
    Brinkmann, Ralf Peter
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2023, 32 (04):
  • [43] LANGMUIR PROBE MEASUREMENT OF ELECTRON-TEMPERATURE IN HIGH-PRESSURE PLASMAS
    CLEMENTS, RM
    SMY, PR
    JOURNAL OF APPLIED PHYSICS, 1973, 44 (08) : 3550 - 3556
  • [44] Effects of Electron Temperature Fluctuation on Turbulence Measurement by Langmuir Probe in a Magnetized Helicon Plasma
    Kawachi Y.
    Inagaki S.
    Sasaki M.
    Kosuga Y.
    Yamada T.
    Nagashima Y.
    Moon C.
    Kasuya N.
    Fujisawa A.
    Plasma and Fusion Research, 2021, 16 : 1202081 - 1
  • [45] Effects of Electron Temperature Fluctuation on Turbulence Measurement by Langmuir Probe in a Magnetized Helicon Plasma
    Kawachi, Yuichi
    Inagaki, Shigeru
    Sasaki, Makoto
    Kosuga, Yusuke
    Yamada, Takuma
    Nagashima, Yoshihiko
    Moon, Chanho
    Kasuya, Naohiro
    Fujisawa, Akihide
    PLASMA AND FUSION RESEARCH, 2021, 16
  • [46] A WORKSTATION BASED LANGMUIR PROBE SYSTEM FOR LOW-PRESSURE DC PLASMAS
    SUDIT, ID
    WOODS, RC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (09): : 2440 - 2448
  • [47] Saturation mechanism of the Weibel instability in weakly magnetized plasmas
    Kato, TN
    PHYSICS OF PLASMAS, 2005, 12 (08) : 1 - 4
  • [48] PLASMA PERMITTIVITY OF WEAKLY IONIZED INHOMOGENEOUS MAGNETIZED PLASMAS
    KISSOVSKI, Z
    SHIVAROVA, A
    PLASMA PHYSICS AND CONTROLLED FUSION, 1995, 37 (10) : 1119 - 1132
  • [49] Weakly nonlinear high frequency waves in magnetized plasmas
    Skjaeraasen, O.
    Pecseli, H.L.
    Trulsen, J.
    Physica Scripta T, T75 : 28 - 32
  • [50] Weakly nonlinear high frequency waves in magnetized plasmas
    Skjaeraasen, O
    Pecseli, HL
    Trulsen, J
    PHYSICA SCRIPTA, 1998, T75 : 28 - 32