Molecularly imprinted polymer-based solid-phase microextraction fiber coupled with molecularly imprinted polymer-based sensor for ultratrace analysis of ascorbic acid

被引:91
作者
Prasad, Bhim Bali [1 ]
Tiwari, Khushaboo [1 ]
Singh, Meenakshi [1 ]
Sharma, Piyush Sindhu [1 ]
Patel, Amit Kumar [1 ]
Srivastava, Shrinkhala [1 ]
机构
[1] Banaras Hindu Univ, Fac Sci, Dept Chem, Analyt Div, Varanasi 221005, Uttar Pradesh, India
关键词
molecularly imprinted solid-phase microextraction; molecularly imprinted polymer-sensor; ascorbic acid; differential pulse; cathodic stripping voltammetry; blood serum;
D O I
10.1016/j.chroma.2008.05.059
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Clinical manifestations owing to ascorbic acid deficiency demand an easy-to-use, rapid, robust and inexpensive technique, which can measure serum ascorbic acid at ultratrace level to attend the problem of hypovitaminosis C and acute cases of scurvy. In the present work, a novel molecularly imprinted polymer (MIP)-coated solid-phase microextraction (SPME) fiber that could be coupled to a complementary MIPsensor was prepared with ascorbic acid as a template molecule. The characteristics and applications of this fiber were investigated. The same MIP receptor for both SPME and the corresponding sensor was able to enhance the preconcentration of analyte substantially so as to attain the stringent level of sensitivity in highly diluted aqueous, blood serum and pharmaceutical samples. The extraction yield of ascorbic acid (AA) with the MIP-coated fiber was found to be quantitative (detection limit 0.0396 ng mL(-1), RSD = 2.3%. S/N = 3) in aqueous samples without any problem of non-specific false positive results and cross-reactivity. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 40 条
[1]   Sol-gel approach to in situ creation of high pH-resistant surface-bonded organic-inorganic hybrid zirconia coating for capillary microextraction (in-tube SPME) [J].
Alhooshani, K ;
Kim, TY ;
Kabir, A ;
Malik, A .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (01) :1-14
[2]   Analysis of biogenic amines by solid-phase microextraction and high-performance liquid chromatography with electrochemical detection [J].
Auger, J ;
Boulay, R ;
Jaillais, B ;
Delion-Vancassel, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :395-403
[3]  
CAMERON E, 1977, INT J ENVIRON STUD, V10, P303, DOI 10.1080/00207237708737653
[4]   High-performance liquid chromatography/electrospray ionization-mass spectrometry for simultaneous determination of taurine and 10 water-soluble vitamins in multivitamin tablets [J].
Chen, Z ;
Chen, B ;
Yao, SZ .
ANALYTICA CHIMICA ACTA, 2006, 569 (1-2) :169-175
[5]   Elevated blood histamine caused by vaccinations and vitamin C deficiency may mimic the shaken baby syndrome [J].
Clemetson, CAB .
MEDICAL HYPOTHESES, 2004, 62 (04) :533-536
[6]   Determination of L-dopa and L-dopamine in aqueous solutions using in-loop SPME coupled with LC [J].
Djozan, D ;
Amir-Zehni, M .
CHROMATOGRAPHIA, 2005, 62 (3-4) :127-132
[7]   Preparation and evaluation of solid-phase microextraction fibers based on monolithic molecularly imprinted polymers for selective extraction of diacetylmorphine and analogous compounds [J].
Djozan, Djavanshir ;
Baheri, Tahmineh .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1166 (1-2) :16-23
[8]   Measurement of intracellular vitamin C levels in human lymphocytes by reverse phase high perfon-nance liquid chromatography (HPLC) [J].
Emadi-Konjin, P ;
Verjee, Z ;
Levin, AV ;
Adeli, K .
CLINICAL BIOCHEMISTRY, 2005, 38 (05) :450-456
[9]  
Fain Olivier, 2003, Eur J Intern Med, V14, P419, DOI 10.1016/j.ejim.2003.08.006
[10]  
HATTERSLEY JG, 1993, J ORTH MED, V8, P229