Simultaneous determination of bromide and nitrate in contaminated waters by ion chromatography using amperometry and absorbance detectors

被引:30
作者
Tirumalesh, K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Isotope Applicat Div, Water Resource Dev Sect, Bombay 400085, Maharashtra, India
关键词
ion chromatography; bromide; nitrate; amperometry; UV absorbance detector;
D O I
10.1016/j.talanta.2007.09.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study describes anew ion chromatography method using a low-capacity anion exchange column with amperometric and absorbance detection for rapid and simultaneous determination of Br- and NO3- in contaminated waters where one of these ions is present in excess compared to other. The use of two detectors overcomes the problem of baseline separation for Br- and NO3- for accurate quantification, which was commonly encountered when using a low-capacity anion exchange column and suppressed conductivity detection mode. The method achieved accurate quantification of these two ions without requirement of baseline separation. The accuracy of 2.8% for NO3- was determined using a quality control sample obtained from UN GEMS/Water PE Study No. 6. The detection limits for Br- and NO3- were 20 and 6 mu g 1(-1) (25 mu 1 sample), respectively. Linearity of these two ions was over three orders of magnitude with a correlation coefficient >0.998. The influence of potential interfering ions was also studied followed by the determination of Br- and NO3- in seawater, unsaturated zone water, soil extract and groundwater. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1428 / 1434
页数:7
相关论文
共 32 条