A new configuration of winglet longitudinal vortex generator to enhance heat transfer in a rectangular channel

被引:96
作者
Tang, L. H. [1 ]
Chu, W. X. [2 ]
Ahmed, N. [2 ]
Zeng, M. [2 ]
机构
[1] Xian Shiyou Univ, Sch Mech Engn, Xian 710065, Peoples R China
[2] Xi An Jiao Tong Univ, Key Lab Thermofluid Sci & Engn, Minist Educ, Xian 710049, Peoples R China
关键词
Rectangular channel; Longitudinal vortex generator; Flow and heat transfer characteristics; Field synergy principle; FIELD SYNERGY PRINCIPLE; FLOW; EXCHANGER; TUBE; PERFORMANCE; MICROCHANNEL; PARAMETERS; NANOFLUID; SURFACE;
D O I
10.1016/j.applthermaleng.2016.05.056
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a new configuration of winglet longitudinal vortex generator (LVG) to enhance heat transfer in rectangular channel is introduced. Furthermore, the effects of two new types of LVGs, i.e. the common flow-up rectangular winglet combined with elliptical pole (Case E) and the common-flow-up delta wing let combined with elliptical pole (Case F), on flow and heat transfer characteristics in a rectangular channel are investigated in detail by three-dimensional CFD numerical simulations. Comparing with the traditional types of winglet LVG (Case A, common-flow-down rectangular winglet; Case B, common flow-down delta winglet; Case C, common-flow-up rectangular winglet; and Case D, common-flow-up delta winglet), the result reveals that Case F provides the best effectiveness of the heat transfer enhancement. The results were analyzed from the prospective of field synergy principle, it was found that the intersection angles between velocity and temperature gradient of all vortex generator (VG) configurations were smaller than that of smooth channel due to influence of LVGs, which was consistent with the field synergy principle, i.e., the smaller the synergy angle the larger the Nusselt number. Compared by the performance evaluation parameter, the average JF factor in the Reynolds number range for Case A, Case B, Case C, Case D, Case E, and Case F were -5.1%, 3.6%, 0.9%, 6.5%, 1.3%, and 7.4% higher than that of smooth channel, which means Case F had the best overall heat transfer performances. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:74 / 84
页数:11
相关论文
共 44 条
[1]   Heat transfer enhancement in a triangular duct using compound nanofluids and turbulators [J].
Ahmed, Hamdi E. ;
Ahmed, M. I. ;
Yusoff, M. Z. .
APPLIED THERMAL ENGINEERING, 2015, 91 :191-201
[2]  
[Anonymous], 2009, THESIS
[3]  
Bejan A., 1995, CONVECTIVE HEAT TRAN, P343
[4]   Hydrodynamic performance of a vortex generator [J].
Brandner, PA ;
Walker, GJ .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2003, 27 (05) :573-582
[5]   Experimental investigation of heat transfer in a channel with new winglet-type vortex generators [J].
Caliskan, S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 78 :604-614
[6]   A study on fluid flow and heat transfer in rectangular microchannels with various longitudinal vortex generators [J].
Chen, Chen ;
Teng, Jyh-Tong ;
Cheng, Ching-Hung ;
Jin, Shiping ;
Huang, Suyi ;
Liu, Chao ;
Lee, Ming-Tsang ;
Pan, Hsin-Hung ;
Greif, Ralph .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 69 :203-214
[7]   Numerical study of liquid flow and heat transfer in rectangular microchannel with longitudinal vortex generators [J].
Ebrahimi, Amin ;
Roohi, Ehsan ;
Kheradmand, Saeid .
APPLIED THERMAL ENGINEERING, 2015, 78 :576-583
[8]   HEAT-TRANSFER EFFECTS OF A LONGITUDINAL VORTEX EMBEDDED IN A TURBULENT BOUNDARY-LAYER [J].
EIBECK, PA ;
EATON, JK .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1987, 109 (01) :16-24
[9]   HEAT-TRANSFER ENHANCEMENT AND DRAG BY LONGITUDINAL VORTEX GENERATORS IN CHANNEL FLOW [J].
FIEBIG, M ;
KALLWEIT, P ;
MITRA, N ;
TIGGELBECK, S .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1991, 4 (01) :103-114
[10]  
Fiebig M., 1986, P 8 INT HEAT TRANSF, P2909, DOI [10.11151.2911402, DOI 10.1115/1.2911462]