Impact of anatomical parameters on optical coherence tomography retinal nerve fiber layer thickness abnormality patterns

被引:0
|
作者
Baniasadi, Neda [1 ,2 ]
Wang, Mengyu [1 ]
Wang, Hui [1 ,3 ]
Jin, Qingying [1 ,4 ]
Mahd, Mufeed [2 ]
Elze, Tobias [1 ]
机构
[1] Harvard Med Sch, Schepens Eye Res Inst, Ophthalmol, Boston, MA 02115 USA
[2] Univ Massachusetts, Biomed Engn & Biotechnol, Lowell, MA 01854 USA
[3] Jilin Univ Finance & Econ, Changchun, Jilin, Peoples R China
[4] Jilin Univ, Changchun, Jilin, Peoples R China
来源
OPTHALMIC TECHNOLOGIES XXVII | 2017年 / 10045卷
关键词
Optical coherence tomography; retinal nerve fiber layer; glaucoma; imaging; image analysis; deviation map; VISUAL-FIELD; VESSEL TRUNK; GLAUCOMA; POSITION; LOCATION; EYES;
D O I
10.1117/12.2251435
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effects of four anatomical parameters (angle between superior and inferior temporal retinal arteries [inter-artery angle, IAA], optic disc [OD] rotation, retinal curvature, and central retinal vessel trunk entry point location [CRVTL]) on retinal nerve fiber layer thickness (RNFLT) abnormality marks by OCT machines. Methods: Cirrus OCT circumpapillary RNFLT measurements and Humphrey visual fields (HVF 24-2) of 421 patients from a large glaucoma clinic were included. Ellipses were fitted to the OD borders. Ellipse rotation relative to the vertical axis defined OD rotation. CRVTL was manually marked on the horizontal axis of the ellipse on the OCT fundus image. IAA was calculated between manually marked retinal artery locations at the 1.73mm radius around OD. Retinal curvature was determined by the inner limiting membrane on the horizontal B-scan closest to the OD center. For each location on the circumpapillary scanning area, logistic regression was used to determine if each of the four parameters had a significant impact on RNFLT abnormality marks independent of disease severity. The results are presented on spatial maps of the entire scanning area. Results: Variations in IAA significantly influenced abnormality marks on 38.8% of the total scanning area, followed by CRVTL (19.2%) and retinal curvature (18.7%). The effect of OD rotation was negligible (<1%). Conclusions: A natural variation in IAA, retinal curvature, and CRVTL can affect OCT abnormality ratings, which may bias clinical diagnosis. Our spatial maps may help OCT manufacturers to introduce location specific norms to ensure that abnormality marks indicate ocular disease instead of variations in eye anatomy.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography
    Malik, A.
    Singh, M.
    Arya, S. K.
    Sood, S.
    Ichhpujani, P.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2012, 4 (01) : 59 - 63
  • [2] A Myopic Normative Database for Retinal Nerve Fiber Layer Thickness Using Optical Coherence Tomography
    Yilmaz, Hayati
    Yesiltas, Yagmur Seda
    Aydemir, Emre
    Aydemir, Gozde Aksoy
    Ozisik, Gulce Gokgoz
    Koylu, Mehmet Talay
    Cagatay, Caglar
    Bayer, Atilla
    JOURNAL OF GLAUCOMA, 2022, 31 (10) : 816 - 825
  • [3] The Effect of Software Upgrade on Optical Coherence Tomography Measurement of the Retinal Nerve Fiber Layer Thickness
    Seibold, Leonard K.
    Kahook, Malik Y.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (04) : 392 - 396
  • [4] Evaluation of the reproducibility of retinal nerve fiber layer thickness and optic nerve head parameters with optical coherence tomography
    Rau, Ricardo
    de Freitas Silva, Andre Luiz
    Alves Salame, Andre Luiz
    Soares Melo Junior, Luiz Alberto
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (05) : 280 - 284
  • [5] Relationship Between Standard Automated Perimetry and Retinal Nerve Fiber Layer Parameters Obtained With Optical Coherence Tomography
    Lopez-Pena, Maria J.
    Ferreras, Antonio
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    JOURNAL OF GLAUCOMA, 2011, 20 (07) : 422 - 432
  • [6] Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Wu, Huijuan
    de Boer, Johannes F.
    Chen, Teresa C.
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 470 - 476
  • [7] Analysis of retinal nerve fiber layer thickness in patients with Pseudoexfoliation syndrome using optical coherence tomography
    Yuksel, Nursen
    Altintas, Oezguel
    Celik, Mustafa
    Ozkan, Berna
    Caglar, Yusuf
    OPHTHALMOLOGICA, 2007, 221 (05) : 299 - 304
  • [8] Peripapillary retinal nerve fiber layer thickness in different glaucoma stages measured by optical coherence tomography
    Zivkovic, Maja
    Jaksic, Vesna
    Jovanovic, Predrag
    Zlatanovic, Marko
    Zlatanovic, Gordana
    Djordjevic-Jocic, Jasmina
    VOJNOSANITETSKI PREGLED, 2017, 74 (02) : 121 - 126
  • [9] Optical coherence tomography and localized defects of the retinal nerve fiber layer
    Teesalu, P
    Tuulonen, A
    Airaksinen, PJ
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (01): : 49 - 52
  • [10] Retinal nerve fiber layer thickness measurements with optical coherence tomography in glaucoma patients and healthy controls
    Mardin, Christian Yahya
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (06) : 784 - 790