Reconstruction Method of Magnetic Induction Tomography based on Filter Back-Projection

被引:0
作者
Ke, Li [1 ,2 ]
Du, Qiang [1 ]
Wang, Xu [2 ]
机构
[1] Shenyang Univ Technol, Inst Biomed & Electromagnet Engn, Shenyang 110178, Liaoning, Peoples R China
[2] North Eastern Univ, Inst Elect Sci &Technol, Shenyang 110004, Peoples R China
来源
2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11 | 2009年
关键词
Magnetic induction tomography(MIT); Filter Back-projection; Image reconstruction;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic Induction Tomography (MIT) is a new method contact-less method of conductivity tomography, and it gets the conductivity of biology based on electromagnetic detecting. In the excitation of excitation coil the biologic tissue inspires perturbation, which could be measured by receiver coils. For the questions of MIT system, a new multi-channel magnetic induction imaging system model with rotatable platform was proposed in this paper, and a reconstruction method based on filter back-projection was presented. First, the detected data was supplemented to a round, and then was interpolated in the reconstruction process. At last the reconstructed image was got. Experiment results demonstrate that this model is an effective model in magnetic detecting and the conductivity of different objects can be distinguished effectively, and the conductivity in the detecting area could be imaging by the model and reconstruction method.
引用
收藏
页码:1906 / +
页数:2
相关论文
共 10 条
[1]   A FEASIBILITY STUDY OF INVIVO ELECTROMAGNETIC IMAGING [J].
ALZEIBAK, S ;
SAUNDERS, NH .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (01) :151-160
[2]   BACK-PROJECTION DISTORTIONS IN APPLIED POTENTIAL TOMOGRAPHY IMAGES DUE TO NONUNIFORM REFERENCE CONDUCTIVITY DISTRIBUTIONS [J].
AVIS, NJ ;
BARBER, DC ;
BROWN, BH ;
KIBER, MA .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 :113-117
[3]   MIT image reconstruction based on edge-preserving regularization [J].
Casanova, R ;
Silva, A ;
Borges, AR .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) :195-207
[4]  
DONG XZ, 2000, J 4 MIL MED U, V21, P1381
[5]   Magnetic induction tomography [J].
Griffiths, H .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (08) :1126-1131
[6]   Magnetic induction tomography: experimental realization [J].
Korjenevsky, A ;
Cherepenin, V ;
Sapetsky, S .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) :89-94
[7]   CONTACTLESS IMPEDANCE MEASUREMENT BY MAGNETIC INDUCTION - A POSSIBLE METHOD FOR INVESTIGATION OF BRAIN IMPEDANCE [J].
NETZ, J ;
FORNER, E ;
HAAGEMANN, S .
PHYSIOLOGICAL MEASUREMENT, 1993, 14 (04) :463-471
[8]   Sensitivity maps and system requirements for magnetic induction tomography using a planar gradiometer [J].
Rosell, J ;
Casañas, R ;
Scharfetter, H .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :121-130
[9]   Absolute conductivity reconstruction in magnetic induction tomography using a nonlinear method [J].
Soleimani, Manuchehr ;
Lionheart, William R. B. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (12) :1521-1530
[10]   Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes [J].
Tidswell, AT ;
Gibson, A ;
Bayford, RH ;
Holder, DS .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :167-175