Rectal Equivalent Uniform Dose Analysis on the Prostate IMRT for Interfraction Organ Motion Using the Gaussian Error Function

被引:0
|
作者
Shan, W.
Chow, J.
Markel, D.
Jiang, R.
机构
关键词
D O I
10.1118/1.3612615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-652
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Effect of magnesium oxide on interfraction prostate motion and rectal filling in prostate cancer radiotherapy. Analysis of a randomized clinical trial
    den Harder, Annemarie M.
    van Gils, Carla H.
    Kotte, Alexis N. T. J.
    van Vulpen, Marco
    Lips, Irene M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (08) : 758 - 761
  • [22] Analysis of Prostate Patient Setup Error and Organ Motion Error Using Calypso Setup Shift and Tracking Data
    Su, Z.
    Farukhi, Y.
    Murphy, M.
    Williamson, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [23] Dose-Volume Evaluation On Calculation Grid Size in Prostate VMAT Using the Gaussian Error Function
    Chow, J.
    Jiang, R.
    Markel, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E294 - E294
  • [24] Dosimetric variations in calculation grid size in prostate VMAT: a dose-volume histogram analysis using the Gaussian error function
    Chow, James C. L.
    Jiang, Runqing
    Markel, Daniel
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (02) : 162 - 170
  • [25] Erratum to: Effect of magnesium oxide on interfraction prostate motion and rectal filling in prostate cancer radiotherapy: analysis of a randomized clinical trial
    A. M. den Harder
    C. H. van Gils
    A. N. Kotte
    M. van Vulpen
    I. M. Lips
    Strahlentherapie und Onkologie, 2014, 190 : 776 - 776
  • [26] Estimating rectal complication in prostate IMRT treatment planning using maximum dose gradient
    Jiang, R.
    Barnett, R.
    Chow, J.
    Chen, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2447 - 2447
  • [27] Sensitivity of treatment plan optimisation for prostate cancer using the equivalent uniform dose (EUD) with respect to the rectal wall volume parameter
    Schwarz, M
    Lebesque, JV
    Mijnheer, BJ
    Damen, EMF
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 (02) : 209 - 218
  • [28] A QUANTIFICATION OF THE INFLUENCE OF ORGAN MOTION ON CONFORMAL VERSUS INTENSITY-MODULATED PELVIC RADIOTHERAPY FOR PROSTATE CANCER BASED ON THE GENERALIZED EQUIVALENT UNIFORM DOSE
    Hysing, L. Bolstad
    Skorpen, T.
    Alber, M.
    Fjellsboe, L.
    Helle, S. I.
    Muren, L. P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S22 - S22
  • [29] Prostate IMRT and VMAT Plan Evaluation Using the PTV Dose-Volume Factor Based On the Guassian Error Function
    Chow, J.
    Jiang, R.
    Kiciak, A.
    Markel, D.
    MEDICAL PHYSICS, 2017, 44 (06) : 2924 - 2924
  • [30] Organ movements and dose exposures in teletherapy of prostate cancer using a rectal balloon
    Elsayed, Hassan
    Boelling, Tobias
    Moustakis, Christos
    Mueller, Stefan-Bodo
    Schueller, Patrick
    Ernst, Iris
    Willich, Normann
    Koenemann, Stefan