A simplified method for busulfan monitoring using dried blood spot in combination with liquid chromatography/tandem mass spectrometry

被引:34
作者
Ansari, Marc [2 ]
Uppugunduri, Chakradhara Rao S. [2 ]
Deglon, Julien [3 ]
Theoret, Yves [4 ]
Versace, Francois [3 ]
Gumy-Pause, Fabienne [2 ]
Ozsahin, Hulya [2 ]
Dayer, Pierre [1 ]
Desmules, Jules [1 ]
Daali, Youssef [1 ]
机构
[1] Univ Hosp Geneva, Clin Pharmacol & Toxicol Serv, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Oncohematol Unit, Dept Pediat, CH-1211 Geneva 14, Switzerland
[3] Univ Ctr Legal Med, Toxicol Unit, Geneva, Switzerland
[4] Univ Montreal, Dept Pharmacol, CHU St Justine, Montreal, PQ H3C 3J7, Canada
关键词
STEM-CELL TRANSPLANTATION; BONE-MARROW-TRANSPLANTATION; CHRONIC MYELOID-LEUKEMIA; TOTAL-BODY IRRADIATION; INTRAVENOUS BUSULFAN; PEDIATRIC-PATIENTS; GRAFT-REJECTION; HUMAN PLASMA; LC-MS/MS; QUANTIFICATION;
D O I
10.1002/rcm.6241
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE Busulfan (Bu) is an important component of the myeloablative conditioning regimen prior to hematopoietic stem cell transplantation (HSCT) especially in children. Intravenously administered Bu exhibits a therapeutic window phenomenon requiring therapeutic drug monitoring. Analytical methods developed for Bu routine monitoring were aimed at using low volumes of biological fluids and development of simple procedures to facilitate the dosage adjustment. In this report, we describe a simple, rapid method for Bu measurement using dried blood spots (DBS) from only 5 mu L of whole blood. METHODS Bu extracted from DBS with methanol was measured by high-performance liquid chromatography with electrospray ionization and tandem mass spectrometry in multiple reaction monitoring mode using D8-Bu as an internal standard. The method was in-house validated evaluating trueness, repeatability, within-laboratory reproducibility, specificity and the lower limit of quantification (LLOQ). RESULTS The method was linear in the calibration range of 1002000?ng?mL1 (r2 >0.99) encompassing the therapeutic concentrations of Bu. A good trueness (<14%), precision (<10%), and recovery (100%) were observed during validation of the method with quality controls of 300, 600 and 1400?ng?mL1. The LLOQ was determined as 50?ng?mL1 and no matrix or carryover effects were observed. The validated method was applied to measure Bu levels in four children receiving infusion of Bu prior to HSCT. A good correlation was observed between the Bu levels measured by DBS and dried plasma spot (DPS) (r2?=?0.96) and between DPS and the GC/MS method (r2?=?0.92). Bu was found to be stable in DBS up to 6?h at room temperature and for 24?h at 4 degrees C. CONCLUSIONS The new DBS method facilitates earlier dosage adjustment during Bu therapy by its specific and simple procedure using 5 mu L of whole blood. Copyright (C) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1437 / 1446
页数:10
相关论文
共 59 条
  • [1] Dried blood spot liquid chromatography assay for therapeutic drug monitoring of metformin
    AbuRuz, S
    Millership, J
    McElnay, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (02): : 202 - 207
  • [2] Stability of benzodiazepines and cocaine in blood spots stored on filter paper
    Alfazil, Abdulkareem A.
    Anderson, Robert A.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2008, 32 (07) : 511 - 515
  • [3] Influence of GST gene polymorphisms on busulfan pharmacokinetics in children
    Ansari, M.
    Lauzon-Joset, J-F
    Vachon, M-F
    Duval, M.
    Theoret, Y.
    Champagne, M. A.
    Krajinovic, M.
    [J]. BONE MARROW TRANSPLANTATION, 2010, 45 (02) : 261 - 267
  • [4] Balasubramanian P, 2001, CLIN CHEM, V47, P766
  • [5] Application of dried blood spots combined with HPLC-MS/MS for the quantification of acetaminophen in toxicokinetic studies
    Barfield, Matt
    Spooner, Neil
    Lad, Rakesh
    Parry, Simon
    Fowles, Susan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (01): : 32 - 37
  • [6] An evaluation of engraftment, toxicity and busulfan concentration in children receiving bone marrow transplantation for leukemia or genetic disease
    Bolinger, AM
    Zangwill, AB
    Slattery, JT
    Glidden, D
    DeSantes, K
    Heyn, L
    Risler, LJ
    Bostrom, B
    Cowan, MJ
    [J]. BONE MARROW TRANSPLANTATION, 2000, 25 (09) : 925 - 930
  • [7] An analysis of the SFSTP guide on validation of chromatographic bioanalytical methods: progresses and limitations
    Boulanger, B
    Chiap, P
    Dewe, W
    Crommen, J
    Hubert, P
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) : 753 - 765
  • [8] A fast and simple assay for busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry using turbulent flow online extraction technology
    Bunch, Dustin R.
    Heideloff, Courtney
    Ritchie, James C.
    Wang, Sihe
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3255 - 3258
  • [9] MARROW TRANSPLANTATION FOR CHRONIC MYELOID-LEUKEMIA - A RANDOMIZED STUDY COMPARING CYCLOPHOSPHAMIDE AND TOTAL-BODY IRRADIATION WITH BUSULFAN AND CYCLOPHOSPHAMIDE
    CLIFT, RA
    BUCKNER, CD
    THOMAS, ED
    BENSINGER, WI
    BOWDEN, R
    BRYANT, E
    DEEG, HJ
    DONEY, KC
    FISHER, LD
    HANSEN, JA
    MARTIN, P
    MCDONALD, GB
    SANDERS, JE
    SCHOCH, G
    SINGER, J
    STORB, R
    SULLIVAN, KM
    WITHERSPOON, RP
    APPELBAUM, FR
    [J]. BLOOD, 1994, 84 (06) : 2036 - 2043
  • [10] Endocrinological late complications after hematopoietic SCT in children
    Cohen, A.
    Bekassy, A. N.
    Gaiero, A.
    Faraci, M.
    Zecca, S.
    Tichelli, A.
    Dini, G.
    [J]. BONE MARROW TRANSPLANTATION, 2008, 41 (Suppl 2) : S43 - S48